Posted on

ESDEMC HBM测试方案对比

ESDEMC的HBM测试设备及服务,针对多种的测试场景拥有不同的测试方案,本文就“手动 – 两引脚”“机械自动化 – 两引脚“”继电器 – 多引脚”测试方案进行对比。

HBM测试方案对比
测试方案手动 – 两引脚机械自动化 – 两引脚继电器 – 多引脚
Test equipment
测试设备
ES612AES612A +  ES650/其他(半)自动化探针台 ES660、ES612A
Test fixture
测试夹具
Test fixture
测试夹具
测试钩、探针探针
(ES650: 探针无固定间距;一般自动化探针台:固定间距探针)
继电器模块+测试夹具转接板
Applicable DUT type
适用DUT类型
晶圆、引脚少的封装器件晶圆、引脚较多的封装器件引脚多的封装器件
Test method
测试方式
手动操作,人工将测试夹具固定至被测引脚对软件设定测试引脚对序列,自动化控制探针接触引脚对,依次测试通过测试夹具转接板固定被测器件,程控继电器通过转接板连接引脚,自动化测试
Test equipment parasitic
测试设备寄生参数
某些测试情况下不属于低寄生测试设备
Test pin pair
测试引脚
1 对 11对11对1、1对N
Test speed
测试速度
中等
Test equipment price
设备造价
中等 ~ 高(取决于探针台价格)中等 ~ 高 (取决于测试引脚数)
Number of applicable pins
适用引脚数量
适用于引脚数少的器件无引脚数量限制取决于继电器模块配置,选择多达2056个引脚
Adapter Board Requirements
转接板需求
不需要不需要需要
Device packaging model requirements
器件建模需求
不需要需要器件引脚信息和位置信息精准模型需要器件引脚功能信息、对应夹具位置信息准确模型
Automaticity
自动化程度
低,依赖人工操作
Accuracy
精度
高,需引脚定位准确一般,受到设备寄生参数影响
Applicable scenarios
适用场景
开发阶段、自动化测试结果部分验证,操作简便晶圆、器件批量两引脚测试芯片等多引脚器件的高密度自动化测试,可与闩锁测试共用机台(需另外配置闩锁测试需要的电源)
Test Consistency
测试一致性
一般,受寄生参数影响
Maintenance and Troubleshooting 维护与故障排除除了主机和波形模块的维护和故障排除,其他较容易除了主机和波形模块外,还需关注整个控制系统的维护与故障排除除了主机和波形模块外,还需关注继电器模组维护与故障排除
Program-Controlled Testing
程控测试
手动测试、软件程控可选软件程控软件程控

Posted on

闩锁(LU)和瞬态闩锁(TLU)标准对比表

闩锁(LU)和瞬态闩锁(TLU)标准对比表.PDF

本表格中的竞品数据来自公开渠道及市场调研,更新时间为2024年11月27日。

 

闩锁(LU)和瞬态闩锁(TLU)标准对比表
闩锁文档 测试条件 被测器件类型 测试管脚 测试脉冲参数 失效判断标准
类别 标准 测试类型 上升时间 下降时间 持续时间 过冲
闩锁
LU
JESD78F.01-2023 过压测试  1.5 倍 Vmax或者MSV(应用二者中较小的) NMOS, CMOS, BiCMOS, SOI 电源管脚 5 us — 5 ms 5 us — 5 ms 2*tr — 1 s
(典型10ms )
< 测试脉冲电压的5% Inom < 25 mA时,    测试后电流超过Inom + 10 mA,判定闩锁发生,或者
Inom > 25 mA时,
测试后电流超过 1.4*Inom,判定闩锁发生
I-Test 电流源测试,电压合规 IO管脚 < 测试脉冲电流的5%
E-Test 电压源测试,电流合规: 在最大工作电压下 Inom超过+- 100mA IO管脚 < 测试脉冲电压的5%
JESD78E-2016 过压测试  1.5 倍 Vmax或者MSV(应用二者中较小的) NMOS, CMOS, BiCMOS, SOI 电源管脚 5 us — 100 ms 5 us — 100 ms 2*tr — 1 s 测试脉冲电压的+/- 5% Inom < 25 mA时,    测试后电流超过Inom + 10 mA,判定闩锁发生,或者
Inom > 25 mA时,
测试后电流超过 1.4*Inom,判定闩锁发生
I-Test 电流源测试,电压合规 IO管脚 1 us — 5 ms 1 us — 5 ms 2*tr — 1 s 测试脉冲电流的+/- 5%
JESD78D-2010 过压测试  1.5 倍 Vmax或者MSV(应用二者中较小的) NMOS, CMOS, BiCMOS, SOI 电源管脚 5 us — 5 ms 5 us — 5 ms 2*tr — 1 s 测试脉冲电压的+/- 5% Inom < 25 mA时,    测试后电流超过Inom + 10 mA,判定闩锁发生,或者
Inom > 25 mA时,
测试后电流超过 1.4*Inom,判定闩锁发生
I-Test 电流源测试,电压合规 IO管脚 测试脉冲电流的+/- 5%
瞬态闩锁
TLU
ANSI/ESD SP5.4.1-2022 电压脉冲过压测试 电压测试 : 0至失效
电压步进: <=0.1 V
NMOS, CMOS, BiCMOS, SOI 电源管脚 <3ns
<10ns
<3ns
<10ns
100ns
10us
Inom < 25 mA时,    测试后电流超过Inom + 10 mA,判定闩锁发生,或者
Inom > 25 mA时,
测试后电流超过 1.4*Inom,判定闩锁发生
电流脉冲过流测试 电流测试 : 0至失效
电流步进:  <10 mA
IO管脚 <3ns
<10ns
<3ns
<10ns
100ns
10us

 

 

Posted on

PB2022.02 低无源互调失真法兰安装同轴连接器的改进设计

下载PDF – 低无源互调失真法兰安装同轴连接器的改进设计

IMPROVED DESIGN OF FLANGE MOUNT COAXIAL CONNECTOR WITH LOW PASSIVE INTERMODULATION DISTORTION

Abstract—Imperfect electrical connections cause multiple problems in radio frequency (RF) measurements, passive intermodulation (PIM) being the most common one. This paper proposes a new design approach to reduce the PIM distortion caused by the imperfect electrical connection in flange mount coaxial connectors. The proposed approach employs a flexible ring embedded in the outer conductor of the flange mount coaxial connector to improve the reliability of the metal electrical connection. A simulation model is further developed to analyze the effects of the embedded ring on the signal transmission performance. The effectiveness of the proposed approach is verified by experiments, demonstrating that the improved design can not only decrease the PIM level by up to 9 dB, but also show a good reliability and stability in the conditions requiring repeated connection and disconnection, and thus, this method has the potential for the application of all flange mount devices.

Index Terms—Passive intermodulation, flange mount coaxial connector, imperfect electrical connections, contact faults.

关键词:无源互调、法兰安装同轴连接器、电气连接不完善、接触故障

I. INTRODUCTION

Passive intermodulation (PIM) is the distortion generated by weak nonlinear characteristics in passive devices such as connectors, multiplexers, etc. [1]-[3]. When two fundamental frequencies (f1, f2) are considered, the possible frequency components of PIM distortion can be described as fN(PIM) =mf1+nf2, where m and n are the coefficients of the fundamental frequencies, N is the order of PIM products, which can be calculated by N=|m|+|n|. The third-order PIM frequencies (2f1-f2, 2f2-f1) are very close to the fundamental frequencies, and thus are difficult to be eliminated by filters [4], [5]. Therefore, reducing PIM distortion in microwave circuits and RF measurement systems is challenging and relies on the design of low PIM devices.

Flange mount coaxial connectors, which have been used extensively to connect printed circuit board (PCB) or flange devices, are the main contributions to the PIM distortion [6], [7]. Three different kinds of sources, the nonlinear oxide (contaminant) films, the ferromagnetic material plating, and the imperfect electrical connections, are considered as the dominant reasons for PIM distortion in coaxial connectors [8]. Sources of both nonlinear oxide (contaminant) films and ferromagnetic material plating have been well concerned [9]- [11]. For example, in [9], the effects of coating materials and iron content in base brass on PIM performance have been investigated. In [10], the PIM distortion caused by aluminum plating-oxide films has been analyzed. In [11], the design guideline and plating standards have been proposed to minimize PIM generation in RF cables and connectors. However, to the best of authors’ knowledge, only a limited number of contributions have focused on the theoretical analysis for the source of imperfect metallic contact [12], [13], the manufacturing approaches for reducing the PIM distortion caused by imperfect electrical connections have not been sufficiently estimated. In practical situations, the manufacturing error, slight deformations of the contact surface, or tightened with insufficient torque, could potentially leads to an imperfect electrical connection in the flange mount surface when connected. Therefore, it is of great importance to design the high-reliability flange mount coaxial connector to reduce the PIM distortion and then improve the performance of the devised RF measurement system.

This paper proposes a modified design to improve the connection reliability and lower the PIM distortion generated by the imperfect electrical connection in N-type flange mount connectors, and this work is organized as follows. In Section II, the structures of the flange mount coaxial connectors are analyzed to investigate the physical mechanism and potential reasons for generating PIM distortion due to the imperfect electrical connection. In Section III, the improved design method is proposed, and the dimension and plating materials of the modified ring are further analyzed to minimize the PIM distortion in the flange mount coaxial connector by imperfect metallic contact. In Section IV, transmission characteristics, including the S21-parameter, the contact impedance, and the transmission loss for the improved design method are discussed to investigate the effect of structural changes on the quality of signal transmission. In Section V, experiments are conducted to validate the effectiveness of the proposed design method. Section VI draws a conclusion for this paper.

II. STRUCTURE ANALYSIS OF FLANGE MOUNT CONNECTORS

To aid visualization and completely understand the physical mechanisms of imperfect electrical connection in the flange mount devices, a photograph of a typical N-type flange mount coaxial connector is shown in Fig. 1. As can be observed in Fig. 1(a), the dimension of the flange mount surface is larger than that of the insulator. The flange mount surface is a square of a side-length 25.4 mm with an area of 645.2 mm2 , and the diameter of the insulator is 9.8 mm with an area of 75.4 mm2 . Accordingly, the area of the flange mount surface is approximately nine times larger than that of the insulator so that the imperfect metallic contact may occur in the flange mount surface with ease. This because the large flange mount surface could be slightly deformed as a result of manufacturing error, tightened with unequal torque on 4-mounting holes. Meanwhile, the outer conductor of the coaxial connector is the inner circle of the flange mount surface. The above two reasons lead to the imperfect metallic contact being easily occurred in the outer conductor of the N-type flange mount coaxial connector, and this phenomenon is further depicted in Fig. 1(b). On the left side of the flange mount surface, a small gap could exist between the flange mount surface and the corresponding connection female due to the deformation of the interconnected surfaces, resulting in the imperfect metallic contact of the N-type flange mount coaxial connector.

From the previous studies [6], [13], two critical factors are responsible for the PIM distortion generated by the imperfect metallic contact, i.e., the electro-thermal (ET) coupling and the variation of the nonlinear oxide (contaminant) films. For the ET PIM, the additional junction impedance emerges and increases with the imperfect metallic contact level, this causes significant self-heating of the connective junction in high-power microwave circuits. On the contrary, the material property, such as metal resistivity, is changed because of the self-heating. Therefore, the resistivity of the junction is nonlinear, and then the ET PIM is generated. For the oxide (contaminant) films PIM distortion, the self-heating accelerates the process of oxidation and increases the thickness of the nonlinear oxide films. Nevertheless, the additional junction impedance makes much more current through nonlinear oxide (contaminant) films, which further deteriorates the PIM level.

Specifically, as shown in Figs. 2(a) and 4(a), a method that designs a gasket on the outer conductor of the traditional flange mount surface has been proposed in industry to reduce the probability of the imperfect metallic contact. Generally, the width d and the height h of the gasket are designed ranges from 0.80 mm to 2.00 mm and 0.12 mm to 0.20 mm respectively.

Although the gasket method can enhance the connection reliability and reduce PIM distortion in the first few uses, the stability of repeated connections and disconnections in the course of service is unsatisfactory. This is due to the fact that, 1) the gasket is the main acceptor of the connection forces between the flange mount surface and the corresponding connection female. 2) the area of the flange mount surface is much larger than that of the gasket. These factors make it easy to have a plastic deformation in the corresponding part of the gasket under the conditions of over-standard tightening torque or requiring frequent connections and disconnections (the element after plastic deformation does not fully recover its original shape).

In summary, the gasket method can improve the connection reliability and diminish PIM level in the first few uses. However, when in the situations requiring frequent disconnection and reconnection, the gasket method may have more serious PIM distortion than the traditional N-type flange mount coaxial connector.

III. DESIGN FOR THE IMPROVED METHOD

In an effort to cure the deficiencies of the proposed gasket design method, in this section, we will provide a modified ring method that is composed of two parts, namely the stress ring and the conducting ring. As shown in Fig. 2(b), the stress ring has the same size as the gasket in Fig. 2(a), the conducting ring is embedded in the stress ring as the outer conductor for the flange mount coaxial connector to transmit the signal. Nevertheless, as illustrated in Figs. 3(a) and 4(c-e), the conducting ring is divided into many ring petals by slots so that there is a small gap between two neighboring ring petals. Therefore, when a connection force is applied in Figs. 3 (c), and 4(e), the ring petals are bent in response to the contact pressure, and then the stress ring will be the main acceptor for the contact pressure. In other words, the imperfect metallic contact and plastic deformation can be avoided in the signal transmission component because the parts for receiving the contact pressure and transmitting the signals are separated (the conducting ring is employed to transmit the signal and only occurs elastic deformation; the stress ring is used to receive the contact pressure and may generates plastic deformation). In addition, the parameters design on the dimension and plating for the modified ring method is discussed as follows.

A. Dimension Design for the Modified Ring

Similar to the gasket in Fig. 2(a), the stress ring is also the main acceptors for the connection forces, therefore, the stress ring and gasket have the same dimension and material, and both need to be heat-treated to improve the hardness. In practical situations, the hardness of them ranges from 28 HRC to 32 HRC, here, HRC represents Rockwell C scale hardness. As shown in Fig. 2(b), the height and width of the conducting ring are l and w, respectively, which refer to the skin depth and plastic deformation of the ring petals. The reasons are summarized as follows.

1). Almost all the conducting current is concentrated in the inner side of the conducting ring on account of the skin effect. Hence, for the integrity of the transmission signals, the width w must be larger than that of the skin depth. For example, as the frequency of the transmitted signal is 30 MHz, the skin depth of brass can be calculated as 24.3 μm (resistivity: ρ=6.98×10-8 Ω/m, relative permeability: μr=0.99994). Therefore, the minimum width w of the Conducting ring should be greater than 24.3 μm.

2). With the same connection force, increasing the height l or decreasing the width w can increase the electric contact reliability. However, as the electric contact level or the deformation of the conducting ring exceeds their limits, the plastic deformation will occur. Therefore, the dimensions of the conducting ring are necessitated to enable the N-type flange mount coaxial connector tightly connected and avoid plastic deformation. In other word, the stress ring should withstand the contact pressure absolutely before the conducting ring is deformed with plastic bending.

Taking the designing principles above into account and considering the tightening torque for all four mounting screws is 3.0 N·m, the width w and the height l of the conducting ring are designed ranges from 0.15 mm to 0.30 mm and 0.25 mm to 0.40 mm, respectively.

B. Plating Design for the Modified Ring

Electroplating can significantly increase the electrical conductivity, corrosion protection, and wear resistance of coaxial connectors. As aforementioned, the skin effect makes almost all transmitted currents concentrated on the surface of the conducting ring, and the stress ring is the main acceptors for the connection forces. Therefore, it is important to plate the conducting and stress rings to enhance the conductivity and wear resistance, respectively.

From the aspect of the practicality and economy, the plating thickness of the conducting and stress rings are designed both from 20 uin to 50 uin (uin: micro inch, 0.50 μm to 1.25 μm). However, the stress ring is plated with nickel to improve the performance of corrosion protection and wear resistance. Two metals, gold and tri-metal alloys (55% Copper, 30% Tin, 15% Zinc), are selected as the plating materials for the conducting ring. Specifically, the plating metal of tri-metal alloys is used in a common sensitivity environment of the PIM distortion. Hence, for the applications, where high PIM sensitivity and electrical conductivity are required, the noble metal (silver, gold, and others) is the optimal choice for plating the conducting ring.

IV. SIMULATIONS FOR THE MODIFIED RING

In this section, the transmission characteristics, including the S21-parameters, the contact impedance, and the transmission loss will be analyzed by simulations to investigate the modified ring structure impacts on the transmission performances for the flange mount coaxial connector. Figs. 3 & 4 show the structures of the simulation model. A voltage source is applied at the left terminal of the simulation model (Fig. 4(f)) to generate a Gaussian pulse excitation signal. At the other end of this model, a 50 Ω load is employed to match the characteristic impedance. Three different kinds of flange mount surfaces are considered, namely the traditional design method (Fig. 1(a)), the gasket design method (Fig. 4(b), and the modified ring design method (Fig. 4(c)). In addition, the side-length of flange mount surface is 25.4 mm, the diameters of the inner conductor and insulator are 3.0 mm and 9.8 mm respectively. The width d and the height h of both the gasket and the stress ring are 1.20 mm and 0.20 mm respectively. The width w and the height l of the Conducting ring are 0.15 mm and 0.30 mm.

In this paper, we will take the mobile communication system of GSM1900 as an example to analyze the PIM distortion in the N-type flange mount coaxial connector. The transmitter and receiver frequency bands for the GSM1900 range from 1930 MHz to 1990 MHz and 1850 MHz to 1910 MHz respectively. Two carriers, f1=1935 MHz and f2=1985 MHz, are selected as the excitation signal, and thus the third order PIM distortion product can be calculated as f3(PIM)=1885 MHz.

Figs. 5-6 show the simulated results of the S21-parameter, the transmission loss, and the contact impedance in the flange mount surface for the above three cases. it is important to notice that, the transmission characteristics of the modified ring method are not only in good agreement with that of the gasket method but also with that of traditional method. Not only that, we have further measured the S21 and S11 parameters for the three different types of flange mount connectors mentioned above, and the measurement results are shown in Fig. 7, which is confirm that all connectors used in measurements have the similar transmission and reflection characteristics.

Therefore, the results of both simulation (Figs. 5-6) and measurement (Fig. 7) indicate that the effect of the structural changes (traditional design → gasket design → modified ring) on the critical transmission characteristics can be ignored. In other word, it proves that the modified ring design method can enhance the connection reliability and stability, but does not degrade the performance of signal transmission.

V. VERIFICATION

For validations, the test setup is composed of a PIM tester, a device under test (DUT), and a terminal load (50 Ω). CCI PiMPro1921 is used as the PIM tester to generate excitation signals and display the reflective PIM values, and the output accuracy of the used PIM tester is 0.3 dB. The 50 Ω terminal load with the feature of low reflection PIM is employed to dissipate the transmitted power.

The DUT is essentially a micro-strip line and connects the PIM tester and the terminal load with two N-type flange mount coaxial connectors. As shown in Fig. 8, the connector on the right side of the micro-strip is a traditional N-type flange mount coaxial connector, however, the connector on the left side of the micro-strip is the employed test sample. Four types of samples, as detailed in Table I, are considered to evaluate the effects of the modified ring design on the PIM levels. It is important to notice that all test samples in measurements are brand new (so that, the effect of the oxide (contaminant) films on PIM distortion can be ignored), and the standard tightening torques for all four mounting screws are 3.0 N·m.

In experiments, the measurement conditions are set as shown in Table II, where, three connection cases of the standard, under-standard, and over-standard are considered in this work. The measurement on the third-order PIM results for the standard connection case is shown in Fig. 9. It is observed that, as the standard tightening torque is applied, the values of PIM distortion can be decreased up to 9 dB by designing the gasket or modified ring on the outer conductor of the traditional flange mount surface (comparing samples B, C with A), and the noble metal (gold) plating can further reduce the PIM distortion levels (modified ring D).

As shown in Table II, for the under-standard connection case, a slight imperfect contact is generated in the flange mount surface because the tightening torque applied to one mounting screw is insufficient (2.0 N·m). Fig. 10 shows the measured third-order PIM values for the under-standard connection. Comparing the measured results of the under-standard case with the standard cases, it is important to notice that the imperfect metal contact can deteriorate the PIM level (the PIM level of traditional A′ is higher than that in traditional A), but we can improve the connection reliability and diminish PIM level by adding a gasket or modified ring on the outer conductor of the traditional flange mount surface (the PIM distortions of samples B, B′, C, and C′ are almost on the same level).

For the over-standard connection case, the employed samples have been repeated connection and disconnection 20 times with the tightening torque 5 N·m, which means the plastic deformation has generated in the connection surface before the PIM test. Fig. 11 shows the third-order PIM results for over-standard connection case. It is observed that, the frequent connecting and disconnecting or over-standard tightening torque can significantly deteriorate the PIM level for the gasket method (Comparing the measured results of gasket B″ with gasket B). However, the PIM level of the modified ring method is almost the same as its original value (the PIM levels of modified rings C and C″are almost in the same range), this is due to the fact that the components for receiving the contact pressure and transmitting the signals are separated in the modified ring method, and thus the frequent disconnection and reconnection or over-standard tightening torque impacts only on the component of receiving the contact pressure, for the component to transmit the signals, the effect can be ignored.

Specifically, from Figs. 9-11, the differences between each two traces are larger than the measurement accuracy of the used PIM tester, and we can further find that the third-order intermodulation does not meet 3 dB/dB relationship with the input signal power, which can be explained by the fact that, a system is usually made up of linear and nonlinear components, the interaction between the linear and nonlinear elements of a system can dramatically transform the overall nonlinear behavior of the system from that of the nonlinear component in isolation [14], [15].

VI. CONCLUSION

In this paper, an improved design for minimizing the PIM distortion in the flange mount connectors has been proposed. Both the detailed design and verification have been provided. Specifically, to meet the requirement of repeated connections, this design has added two components for receiving the contact pressure and transmitting the signals respectively.

From the investigation in this paper, the proposed design method can not only significantly decrease the PIM distortion level caused by imperfect metallic contact, but also increase the reliability and stability for the flange mount coaxial connector in the conditions of over-standard tightening torque or requiring frequent disconnection and reconnection. Furthermore, this work has the potential to extend for all flange mount devices in engineering.

ACKNOWLEDGMENT

The authors would like to thank Dr. Yihong Qi, for his helps in technical supports and in the manufacturing the test samples.

Posted on

PB2022.01 不对称电接触引起的无源互调失真分析

下载PDF – 不对称电接触引起的无源互调失真分析

ANALYSIS OF PASSIVE INTERMODULATION DISTORTION CAUSED BY ASYMMETRIC ELECTRICAL CONTACT

Abstract— This article investigates the passive intermodulation (PIM) distortion induced by the asymmetric electrical contact. Based on the analytical model, it is found that the increased current path is the cause of the additional impedance, resulting in PIM distortion. To validate our theoretical analysis, different levels of asymmetric electrical contact are studied via simulation and experiments. The demonstrations not only confirm the validity of our theoretical findings, but also substantiate the simulations. To the best of our knowledge, this work is the first to identify the asymmetric electrical contact as a PIM source and discuss its underlying physical mechanisms of causing electrothermal (ET) coupling PIM.

Index Terms— Asymmetric electrical contact, electrical contact failures, electro-thermal (ET) coupling, passive intermodulation (PIM)

关键词:不对称电接触、电接触失效、电热(ET)耦合、无源互调(PIM)

I. INTRODUCTION

Passive intermodulation (PIM) distortion is a frequently encountered issue in microwave circuits and wireless systems. PIM phenomenon is caused by slight nonlinearities stemming from nonlinear material or nonlinear metallic contact. In the past decades, many physical mechanisms, namely electro-thermal (ET) coupling, ferromagnetic materials, tunneling effect, and field emission, are considered as PIM sources [1]–[4].

The ET coupling generally has not been considered as a dominant PIM mechanism in the traditional sparse frequency bands and low-power telecommunications [5]. However, with the further development of wireless technologies (e.g., high power, high frequency, and base station supporting 3G/4G/5G simultaneously), the ET PIM distortion, especially induced by electrical contact failures, needs to be addressed carefully.

In practical scenarios, the poorly soldered joints, oxidation, and corrosion of junctions in the courses of service, and minor deformations of the connection surfaces may lead to electrical contact failures in microwave circuits [6]. According to prior research [7], electrical contact failure increases the contact impedance of the connection surface. Typically, in high-power and high-frequency circuits, the increased contact impedance (additional impedance) will lead to significant self-heating. Furthermore, the material properties, such as metal resistivity, change as self-heating conditions vary. In other words, this bidirectional interaction between the electromagnetic domain (dissipated electrical power and the resultant self-heating) and the thermal domain (temperature rise and the consequent change in the metal resistivity), gives rise to temperature oscillations and resistivity variations. Therefore, the ET PIM distortion emerges due to the nonlinear contact impedance [8].

Specifically, electrical contact failures will increase the noncontact areas and lead to asymmetric electrical contact in the connected surface, that is, there are two important factors responsible for the ET PIM caused by electrical contact failures: one is the increased noncontact areas, while the other is an asymmetric electrical contact. In [9] and [10], PIM distortion induced by the additional impedance of the increased noncontact areas has been analyzed. In [11], the theories for ET PIM caused by the electrical contact failures have been studied, and a numerical expression was derived to calculate the PIM distortion related to the contact impedance. However, the impedance induced by the asymmetric electrical contact has been ignored, which renders the PIM distortion evaluated by the theoretical analysis insufficient.

In this article, we take a pair of faulty coaxial connectors as a case study to investigate the ET PIM distortion caused by the asymmetric electrical contact, and this work is organized as follows: Section II develops an analytical model of the asymmetric electrical contact, considering the case of coaxial connectors. In Section III, simulations are conducted to validate our theoretical analysis. In Section IV, experiments are conducted to check the goodness of the model and the consistency of the simulation results. Finally, Section V draws a conclusion of this article. In summary, the main contributions of this work are that it, for the first time, reveals the asymmetric electrical contact as a PIM source and discusses its underlying physical mechanisms, which will facilitate further improvements of the accuracy of PIM predictions and measurements related to the electrical contact failures.

II. ANALYSIS OF ASYMMETRIC ELECTRICAL CONTACT

A. Analytical Model for the Asymmetric Electrical Contact

To aid visualization and better understanding of the asymmetric electrical contact, a used coaxial connector sample is shown in Fig. 1, where the black solid/dashed lines enclose the actual contact areas of the female/male coaxial connectors. On the inner conductor of the coaxial connector, there are some small deformations. This makes the connected petals between the male and female coaxial connectors slightly unaligned, which increases the noncontact areas in the outer conductor and creates asymmetric electrical contacts in the inner conductor. In other words, the asymmetric electrical contact emerges and increases with the deformation levels of the connection surface.

As previously stated, the impedance is the dominant contributor to ET PIM, and a numerical relationship between the ET PIM and the impedance for lossy component has been developed by (33) in [8]. Therefore, the key to understanding ET PIM distortion caused by asymmetric electrical contact is to analyze the increased contact impedance, that is, when the associated physical mechanisms for the increased contact impedance are well understood, the ET PIM can be accurately calculated.

Fig. 2 shows the analytical model of this work, where two cases of symmetric and asymmetric electrical contact are considered to analyze the impedance characteristics in the connection surface. The total contact areas are the same in both cases, that is, A1 = A0 = B1 = B0 = C1 = C0, but one focuses on the symmetric contact (the left side of Fig. 2), while the other studies the asymmetric contact (the right side of Fig. 2). It is evident that the total lengths of the current paths in the asymmetric contact are longer than that in the symmetric contact. For example, the red solid line in the asymmetric noncontact area A1 is longer than that in the symmetric noncontact area A0.

From the classical electrical contact theory [6], the contact impedance increases with the length of the current path through the connection interface. Therefore, the asymmetric electrical contact creates more contact impedance than the symmetric electrical contact. Furthermore, the increased impedance is proportional to the level of asymmetry, which means the severer the asymmetry of the electrical contact is, the more additional impedance will be induced.

B. Simulations for the Asymmetric Electrical Contact

A simulation model of a typical 7/16 DIN coaxial connector, which is built in CST Microwave Studio, is employed to analyze the asymmetric electrical contact. As shown in Fig. 3, the length of the model is 20 mm. The inside diameter of the outer conductor and the outside diameter of the inner conductor are 16 and 7 mm, respectively. The thickness of the noncontact areas is 0.3 mm, and the asymmetric contact occurs at 10 mm from the right end. Materials for the contact and noncontact areas of the simulation model are white bronze (conductivity: 5.96 × 107 S/m) and air (εγ = 1.0059), respectively.

Four cases, namely the symmetric contact, small asymmetry, medium asymmetry, and severe asymmetry, are designed and implemented to investigate the increased contact impedance in different asymmetric contact conditions. Fig. 4 shows the simulation results for these four cases. Here, the variable


Z, which is the additional impedance, is the difference between a certain asymmetric electrical contact case (e.g., severe asymmetry) and the symmetric contact case when the peak impedance occurs. It is important to notice that, as there is a symmetric contact, the additional impedance


Z emerges and increases with the asymmetric contact level. Therefore, the simulation results correlate well with the analysis in the analytical model.

C. PIM Expression for the Asymmetric Electrical Contact

The ET theory has demonstrated that the ET PIM distortion originates from the nonlinearity of the impedance [8], Specifically, for the coaxial connector, the ET PIM can be written as

where k belongs to the natural numbers, Z is contact impedance of the connected interface, in(t) is the current through the connected interface, α is the temperature coefficient, and Tα is the ambient temperature. Rth.eq. is the equivalent thermal resistance, which is related to the thermal capacitance Cth, thermal resistance Rth, and carrier angular frequency ω, meeting the relationship as [12]

Typically, the third-order PIM frequencies are very close to the fundamental frequencies and thus are difficult to be eliminated by filters. Below, we will take the third-order PIM distortion as an example to understand the generation of ET PIM by the asymmetric electrical contact. Usually, the magnitude of the temperature coefficient α is in the order of 10−3, thus, the ET PIM distortion from the number of k ≥ 2 can be ignored, and then the third-order ET PIM distortion can be approximately expressed as

Furthermore, as the current signal in(t) is composed of two carriers, n 1, 2, with amplitudes In, frequencies fn, and angular phases ϕn, mathematically

where ωn = 2π fn , then the third-order ET PIM distortion generated by the asymmetric electrical contact can be further rewritten as

where Z0 is the contact impedance of the connected interface with the symmetric electrical contact and


Z is the additional impedance caused by the asymmetric electrical contact.

III. DEMONSTRATIONS

It has been analyzed and simulated in Section II that the asymmetric electrical contact induces an additional contact impedance, resulting in ET PIM distortion. In this section, experiments are conducted to verify the impacts of the asymmetric electrical contact on PIM distortion, and the measurements are made in the mobile communication system of GSM1900, that is, the transmitter/receiver frequency bands of the experiments range from 1930 to 1990 MHz and 1850 to 1910 MHz, respectively.

A 7/16 DIN coaxial connector is employed as the device under test (DUT), and different levels of asymmetric electrical contacts are achieved by embedding copper on the different locations of the inner or outer conductor surfaces. Since the height of the embedded copper is a bit higher than that of the outer/inner conductor surface, and therefore, when the male and female coaxial connectors form a connection, the contact areas are only consisted of the embedded coppers, which means the asymmetry can be controlled by changing the locations of the embedded coppers.

Furthermore, three cases of different symmetry have been designed in experiments, which are the symmetric contact [Fig. 5(a)], the medium asymmetric contact [Fig. 5(b)], and severe asymmetric contact [Fig. 5(c)]. They have the same contact area, but the symmetry is different, that is, the embedded coppers for the three cases are the same dimensions, but they are embedded in different locations (the total area of the embedded coppers is one-quarter of the apparent contact area of the 7/16 DIN coaxial connector).

As illustrated in Fig. 5, the reflected PIM testing technology is used for the principle of the PIM analyzer; in other words, the PIM tester first generates a dual-tone excitation signal ( f1 = 1935 MHz, f2 = 1985 MHz) to the DUT, and then the reflected third-order PIM values from the DUT are measured and displayed on the PIM tester.

Fig. 6 shows the measured and predicted results for the three asymmetric electrical contact cases in Fig. 5. Two conclusions can be drawn from Fig. 6: 1) the third-order PIM distortion is directly proportional to the level of asymmetric electrical contact (symmetric contact → medium asymmetric contact → severe asymmetric contact) and 2) the nonlinearity of the PIM distortion is also confirmed because there is not a fixed step between all the curves.

Meanwhile, it is important to notice that the predicted PIM value is lower than in measurement. This is due to the fact that, in practical scenarios, the connected surface may have other PIM source (e.g., electron tunneling effect), which has been ignored in the theoretical analysis. Furthermore, the PIM values of both measured and predicted are greater than that of the reference because when embedding the coppers, the real contact area of the connected surface is reduced. In summary, the experiments quantitatively and qualitatively demonstrate that the asymmetric electrical contact is a PIM source.

IV. CONCLUSION

Although it is well known that the electrical connection failures generate the ET PIM distortion, it is not very clear how it works for asymmetric connection scenarios. In this work, the underlying relationship between asymmetric electrical contact and ET PIM has been studied. It is revealed that the asymmetric electrical contact could increase the path length of the transmitted current through the connection interface, and the increased current path in turn leads to the emergence of additional impedance. Furthermore, the PIM distortion was generated in response to the ET coupling caused by the additional impedance. This conclusion will facilitate improved prediction and suppression of the ET PIM distortion from the asymmetric electrical contact and can also be extended to other types of connectors or soldered joints.

Posted on

PB2021.10 JS-002标准的1Ω盘式电阻器全波建模

下载PDF – JS-002标准的1 Ω盘式电阻器全波建模 

1 Ω DISK RESISTOR FULL-WAVE MODELING FOR JS-002 STANDARD

Abstract –A 1 Ω disk resistor is specified in the CDM standard as the current sensing element. However, its transfer impedance is frequency dependent which is not considered in the standard. In this work, a full-wave model and a simple equivalent circuit model is provided to explain the root cause of the variation the transfer impedance of the 1 Ω disk resistor.

I. Introduction

When the pin or pad of a charged IC approaches an external metal object, and the breakdown voltage is exceeded a Charged Device Model (CDM) event occurs. During CDM testing, the discharge current of the CDM event is measured by a 1 Ω disk resistor sensing element that is located at the top of a pogo pin probe as described in the industry standard ANSI/ESDA/JEDEC JS-002 [1]-[3]. The resistance of this element is specified to have a value of 1.0 Ω ± 10% and a transfer impedance that does not have a deviation relative to the DC value greater than 3 dB up to 9 GHz [3]. The standard does not consider frequency variations of the transfer impedance when calculating the current from the measured voltage. This work investigates this assumption by characterizing the sensing element (1 Ω disk resistor) of a field induced CDM tester in the frequency domain. Additionally, a simple circuit model and a full-wave model are presented to explain the variation of the transfer impedance up to 27 GHz.

II. CDM tester

A. Discharge Circuit

The cross section of a CDM tester [3] is shown in Figure 1.

To charge the device, the field plate is brought to the specified charge voltage, then the pogo pin is lowered to contact the DUT pin. A spark is initiated and the current flows via the pogo pin to the 1 Ω disk resistor (Figure 2). The transfer impedance, properties of the oscilloscope and cable losses will determine the voltage that is displayed at the scope. The voltage is measured across the 1 Ω disk resistor from which the discharge current waveform is then calculated. However, the transfer impedance of the 1 Ω disk resistor is not constant over the frequency range and deviates from the DC value of the 1 Ω resistor [5].

B. 1 Ω Disk Resistor Measurement

As shown in Figure 2, the disk resistor consists of a resistive sheet on one side and a ceramic substrate made from beryllium oxide (BeO) on the other side that provides mechanical strength. In a CDM test head, the resistive sheet can be mounted downward (Figure 3a, resistive sheet towards pogo tip) or upward (Figure 3b, resistive sheet towards coaxial line).

Figure 4a shows a fixture to measure the disk resistor. The fixture is composed of two 50 Ω surface mountable connectors and a plate that aligns the disk resistor. The thickness of the plate was chosen to prevent any gap between the 50 Ω connectors and the surface of the disk resistor. The surface mount connectors were connected to ports 1 and 2 of a VNA and port extensions were performed up to the connector surfaces (Figure 4a). Figure 4b shows the definition of current and voltage of the two-port measurement setup (disk resistor setup measured with VNA). Knowing the S-parameter across the disk resistor, the transfer impedance of the disk can be calculated as in [6]:

As shown in Figure 5, the S21 and S12 of the disk are nearly identical which gives evidence for the accuracy of the measurement. However, the S22 and S11 are different (Figure 6). Port 1 of the measurement fixture (Figure 4) is toward the resistive sheet of the disk resistor, and port 2 is connected to the ceramic side of the disk. The reflection coefficient S11 is nearly flat but S22 has lower value at higher frequencies. The difference between S11 and S22 is important in understanding the CDM system behavior at high frequencies. Ringing was observed in the time domain discharge waveform if the substrate is mounted toward the pogo-pin but it reduced if the disk was flipped. The ringing will be discussed in Section IV of this paper. At low frequencies, the transfer impedance equals the disk resistance. Thus, the impedance measured with VNA should match the measurements obtained by an LCR meter (1 Ω @ 1kHz).

As shown in Table I, both LCR Meter (@ 1kHz) and disk measurements (Figure 4) show about 1 Ω for different orientations of disk (up to 1GHz). For each sample, both methods showed nearly identical low frequency values (Figure 7). At higher frequencies, the transfer impedance obtained using (1) is increasing with frequency (Figure 8) for all disks. Additionally, manufacturing tolerances lead to variations between disk samples. The behavior of the S21 can be explained using a simple circuit model in the next section.

III. Device Modeling

A. Simple Circuit Model

Although different disk resistors showed slightly different transfer impedance values versus frequency, they all behave similar (Figure 8). The transfer impedance of the disks increased with frequency from 1 Ω @ 1 MHz to about 3 Ω @ 20 GHz. This behavior can be explained by the influence of the ceramic substrate. It forms a short, 13 ps delay transmission line (see Figure 2) which acts as transmission line transformer and changes the match of the 1 Ω disk side to the 50 Ω system. The substrate has a relative permittivity of around 7. However, the structure is not easy to model in 3D due to possibility of higher order modes if they are excited. Only considering TEM modes, a simple circuit model is created in Advanced Design System (ADS) [7] to evaluate the influence of the short ceramic transmission line (Figure 9).

Based on the geometry and permittivity of the Beryllium Oxide (BeO) substrate, the characteristic impedance of the ceramic portion was calculated to be roughly 17 Ω. A 13 ps long 17 Ω lambda/4 transmission line transformer converts 50 Ω to transfer impedance of about 3 Ω at 20 GHz which can be calculated with (1).

This transmission line behavior explains the observed increase of S21 and transfer impedance. As shown in Figure 10, S11 is almost flat over the entire frequency range whereas S22 decreases with frequency as the short transmission line changes the match to 50 Ω. A comparison between measured impedance and calculated from the simple circuit model will be discussed in the next section.

B. Full-wave Model

The simple circuit model gives a qualitative insight into only the dominating effects, excluding the influence of the skin effect, higher order modes, and details of the geometry. A full-wave model can reveal additional details about the frequency-dependent impedance. Figure 11 shows the core elements of the full-wave model: the 50 Ω connectors, the geometry of the disk resistor, and two waveguide ports which are placed across the 50 Ω connectors. Two short 50 Ω connectors are placed on both sides of the disk. As shown in Figure 2, the 1 Ω disk resistor has a resistive sheet on one side and a ceramic carrier made of beryllium oxide on the other side. A thin resistive sheet material (this does not model skin effect) and BeO were imported from the library of CST Studio Suite [8].

C. Comparison Between Measurement and Simulation

Figure 12 and Figure 13 compares the magnitude and phase variation data for the measured, circuit model, and full-wave model of the 1 Ω disk resistor. Both models and the data agree on the increase of the impedance above 1 GHz and the peak around 20 GHz. This increase and the peaking may cause some error in the peak current measurement for CDM if the actual current contains relevant spectral content in this frequency range.

The fact that the simple circuit model and the measured data match up to 20 GHz can be seen as indicator that the short transmission line is the dominating reason for the observed increase in transfer impedance and the behavior of S11 and S22. The full-wave model predicted a higher peak value, 3.3 Ω relative to 2.6 Ω in the measurements (Figure 12 for resistive sheet down). The reason is not known, but as the frequency matches the other data one can be assured that the dielectric constant of the BeO was correctly estimated from literature data. The full-wave simulation shows additional resonant behavior around 25 GHz which is also seen in the measurements in the same frequency range. We have not investigated the field distribution at these frequencies within the full-wave results to identify the nature of these resonances. Furthermore, the transfer impedance of the disk may decrease at higher frequencies when skin effect starts to decouple the front and the back side of the very thin resistive sheet. As the authors do not know the exact thickness and material of the resistive layer, it is not known above which frequency the decoupling effect of the skin effect would reduce S21. The data indicates that this is not the case below 20 GHz, as the simple ADS model matches the measurement in its principle behavior. Our full-wave model is also not able to simulate skin effect as an infinitely thin electrical layer was used to model the resistive sheet. The metallization of the resistive layer may not be fully homogeneous. This would cause a current flow that is not radially symmetric. As known from current shunts, this would increase the mutual inductance between both sides of the resistive disk. Such a behavior is not observed which leads to a tentative conclusion that the resistive sheet is homogeneous within the boundaries of the analysis.

IV. Effect of Disk Orientation on CDM Event

To investigate the effect of disk orientation, both measured and simulated results have been compared in a CDM test setup.

A. Effect of Disk Orientation on Measured Discharge Current

CDM classification levels have been reduced [9] and that further reductions are to be expected. This will lead to a faster rise time in CDM. This, paired with faster I/O on ICs may lead to measurement problems in CDM testing due to the mounting direction of the disk resistor. To investigate the effect of disk orientation, CDM discharge tests have been measured using a 23 GHz bandwidth oscilloscope [10] with different orientations of disk resistor as shown in Figure 3. One disk resistor was used within one test head by flipping the orientation between tests to prevent any unwanted effects or variation in the test setup. Discharge data from multiple pogo-pins with different length and discharge currents have been captured for charge voltage of 500 V (Figure 14 through Figure 17).

As shown, all plots have a low frequency component around 1 GHz which is the main CDM discharge current. However, there are some high frequency components as well which create ringing waveform over the low frequency waveform. As shown, high frequency ringing was observed in discharge current when the resistive sheet of disk resistor was mounted upward (Figure 3b).

However, the ringing is weaker if the resistive sheet of disk resistor is mounted downward (substrate toward oscilloscope and the resistive sheet toward DUT as shown in Figure 3a). To isolate the ringing from the familiar low frequency response, a Maximum Overlap Discrete Wavelet Transform based Multiresolution Analysis (MODWT MRA) was used [11]. This method yields excellent decomposition and reconstruction while maintaining sharp edge definition and minimizing non-causality introduced by traditional high pass filtering. The high frequency ringing signal was found to be well isolated from the rest of the signal by using the db7 wavelet with a scaling factor of 2. Furthermore, the Wigner-Ville distribution [12] of ringing is used to visualize the time dependent frequency composition of the time dependent current.

The time domain signal, the power spectral density and time-frequency scalogram of ringing for different pogo-pins and for resistive sheet up and down is shown in Figure 18 and Figure 19. As indicated in timefrequency spectra of Figure 18, when the disk resistor is mounted upward for pogo pin length of 8.25 mm, 9.4 mm and 10.5 mm, there are two main high frequency component which make up the ringing with the corresponding interference term between the two main components.

However, in all time-frequency spectra of Figure 19, there is only one frequency component. Similarly, when the resistive sheet of disk resistor is mounted upward the power spectrum has two main frequency components for pogo pin length of 8.25 mm, 9.4 mm and 10.5 mm. Table II summarizes the two observed frequencies if the resistive sheet of disk is mounted upward (Figure 18).

Two sinusoidal signals are used in Figure 20 to reconstruct the ringing for pogo pin of 10.5 mm (blue curve in Figure 20) and is compared with the original ringing (red curve in Figure 20).

Therefore, it is possible to reconstruct the ringing by summing two sinusoidal signals e.g., f1 and f2 as shown in Figure 20. This motivates us to consider the nature of ringing and determine the physical agents which correspond to these responses.

Figure 21 shows the half wavelength versus frequency (blue curve) and is compared with the length of the pogo pins versus the first sinusoidal signal (f1) from Table II (black curve). As shown, the first sinusoidal signal (f1) is directly related to the length of pogo pin and can be calculated relative to the length of the pogo pin. The second sinusoidal component is related to the disk orientation. As shown in Figure 18 and 19, the second sinusoidal signal (f2) exist for resistive sheet upward for pogo pin 8.25 mm, 9.4 mm and 10.5 mm. However, this signal disappears when the resistive sheet is mounted downward. For the pogo pin 6.6 mm, two sinusoidal signals cannot be distinguished since f1 is very close to f2. When the resistive sheet of disk resistor in mounted downward (resistive sheet toward DUT), only one frequency can be observed in time-frequency spectrum of ringing signal (Figure 19) which indicate the effect of disk orientation.

B. Effect of Disk Orientation in Simulation

As shown in Figure 18 through Figure 20, two sinusoidal signals contribute to the high-frequency ringing of the CDM discharge current. A full-wave model is created for CDM test setup (Figure 22) to obtain a qualitative insight into the dominating effects up to 30 GHz. Two discrete ports are placed on both sides of the pogo pin providing the corresponding connection for co-simulation simulation in ADS which is shown in Figure 23. Measured S-parameters of the 1 Ω disk resistor from Section II or simulated S-parameter file from Section III can be imported into ADS model of Figure 23. It is also possible to use the simple circuit model of the disk resistor (Figure 9) into the circuit model of Figure 23. As shown in Figure 24 and Figure 25, if the orientation of the disk is changed, the high frequency ringing also changes. The first ringing in the discharge current relates to the length of the pogo pin which exists in the discharge current regardless of disk orientation. However, the second ringing corresponds to the disk orientation and will disappear if the resistive sheet of the disk is mounted toward the DUT (red curve of Figure 24 and Figure 25). If the substrate of the disk is mounted toward the DUT (blue curve in Figure 24 and Figure 25), the waveform has more ringing (high frequency contents).

The effect of disk orientation in simulated data (Figure 24 and Figure 25) is not as strong as the measured waveform (Figure 14 through Figure 17), but in principle they follow the same behavior, i.e., ringing is stronger if the ceramic substrate is mounted toward the DUT and gets weak if the resistive sheet is mounted toward the DUT.

It is known that the current measured at disk is not necessarily equal to the current at the DUT [13]. Ultimately, the current at the DUT is the stress that the device experienced. For accurate comparison between measured and simulated data in this paper, only current at the disk resistor was studied. Future work should incorporate current at the DUT to get a more accurate measurement of the stress that the device experiences.

A. Discussion

The fundamental question is how important is the frequency response of the transfer impedance of the disk resistor above 10 GHz?

Present ICs have data rates up to 50 GHz and more. Thus, their I/O can be damaged by high frequency content of every strong signal [14]. The charge voltages of CDM will be further reduced such that the rise times will further reduce [9]. Thus, the importance of the larger than 10 GHz spectral content will increase. Right now, CC-TLP testers can be based on a 40 ps or less transmission line pulser [14]. A 30 ps rise time equates to 10 GHz. To avoid problems in testing of future ICs and for comparing test methods, the analysis > 10 GHz is suggested.

V. Conclusion and Further Investigations

The frequency response of the transfer impedance of a 1 Ω disk resistor has been investigated through measurement, full-wave modeling, and a simplified equivalent circuit. The transfer impedance increases with frequency and shows a maximum of about 3 Ω at 20 GHz for disks mounted downward (resistive sheet toward DUT). However, the transfer impedance increases with frequency and shows a maximum of about 15-20 Ω around 20 GHz for a disk mounted upward (resistive sheet toward oscilloscope).

This is explained by considering the inner structure of the 1 Ω disk resistor. Only one side of the resistor’s ceramic carrier contains the resistive sheet material. Thus, it is asymmetric. The thin ceramic carrier creates a short transmission line. The effect of this short transmission line section is clearly visible in measurement, simplified and full-wave simulation both in S11, S22 and S21 data. It cannot match the 1 Ω but it strongly changes the match and causes an increase of the transfer impedance. The CDM current has been captured with different pogo pin lengths. High frequency ringing was observed. It can be explained as the sum of two sinusoids. The first sinusoidal signal was directly related to the resonance frequency of the pogo pin structure, i.e., its length and the second one was created due to the transfer impedance of the disk orientation.

VI. Acknowledgements

We would like to thank Dr. David Johnnsson and Dr. Timothy Maloney for their useful discussions and comments.

Posted on

PB2021.10 分析不平衡的两线或三线VHF LISN对交流电缆辐射发射的影响

下载PDF – 分析不平衡的两线或三线VHF LISN对交流电辐射发射的影响

ANALYZING THE INFLUENCE OF IMBALANCED TWO- OR THREE-WIRE VHF LISN ON RADIATED EMISSIONS FROM AC CABLES

Abstract—This article investigates using imbalanced two- and three-wire terminations for ac main cables, as suggested by the standard group. These terminations provide the basis for a new line impedance stabilization network (LISN) whose objective is to improve test repeatability between labs while also providing better estimation of real-world emissions. Standard balanced LISNs do not reproduce the imbalanced terminations seen in practice. An imbalanced two- or three-wire very high-frequency LISN was built, which can handle up to 15 A on each line. The LISN operates from 30 to 200 MHz and provides greater than 50-dB isolation between the input and output. The imbalanced termination allows the device to create a specified degree of conversion from differential-mode to common-mode current, which can increase radiated emissions. This conversion was evaluated to be as high as 12 dB in measurements of a power line communication device. 3-D full-wave simulations of two- and three-wire applications demonstrate that the radiated emissions from the prototype LISN and the ideal imbalanced termination are nearly equal. The new LISN was further evaluated to show promise for improving measurement reproducibility, reducing the standard compliance uncertainty by 6 dB in this study, from 15.5 dB in CISPR 16-4-1 to 9.5 dB with the LISN.

Index Terms—Common-mode impedance, radiated emissions, termination device, very high-frequency line impedance stabilization network (VHF LISN).

关键词:共模阻抗、辐射发射、终端设备、很高频线路阻抗稳定网络(VHF LISN)

I. INTRODUCTION

Common mode conducted emissions are typically measured using a line impedance stabilization network (LISN) [1]–[9]. An LISN is a filtering device providing a) isolation of the device under test (DUT) from ac power lines and related radio frequency (RF) disturbances, b) a well-defined reference impedance at the LISN DUT port; and c) the necessary power to the DUT. Standard LISNs use a balanced termination structure [3]–[9]. Round-robin testing for radiated emissions show that the average emissions differ by 4 dB when using a traditional balanced LISN (see Fig. 1) [3], [4], but those deviations in measurements were as large as +18/−10 dB when the DUT was plugged directly into the building mains [3], [4]. Although a goal of the balanced very high-frequency (VHF) LISN is to reduce variations among tests [1]–[9], a balanced termination is rarely available in practice, so real-world emissions may be higher than seen in many standardized measurements.

The LISN forms an impedance between the wires of the power cable and the chamber ground and, thus, can be used as a common-mode absorption device above 30 MHz. If the common-mode impedance of the LISN is between 50 and 300 Ω, most of the common-mode resonances of the power cable will be suppressed. Suppressing these resonances reduces the dependence of the emissions on the power cable routing, the specific impedance of the chamber’s power connection, and the length of the power cord. While reducing this dependence is attractive for minimizing chamber to chamber variations, it also hides an important effect that causes radiation. In real installations, the differential-mode noise current is often larger than the common-mode noise current in a power cable, and real installations will have asymmetric common-mode impedances [10]–[12]. This asymmetry will convert differential-mode current into common-mode current, which can radiate. To mimic this effect, a defined asymmetry can be introduced into the VHF LISN.

Using an imbalanced termination will increase the common-mode emissions by about 10 to 15 dB up to 200 MHz (depending on the DUT) compared to using a balanced termination [11]. About 10-dB higher emissions were also reported for an imbalanced two-wire LISN compare to a balanced LISN over 0.5 to 30 MHz in [11]. To address the differential- to common-mode current conversion in a VHF LISN (30 to 200 MHz), the termination impedance should have a controlled imbalance to provide a defined degree of conversion from differential to common-mode current. The standard group introduced an imbalanced termination for this purpose and suggested that an LISN with similar performance should be created for the 30- to 200-MHz frequency range [10].

In this article, an imbalanced LISN with the characteristics suggested by the works in [10]–[12] was designed, built, and analyzed to serve as the termination of the mains power during radiated EMI CISPR16/CISPR 35 testing [1]. This LISN was designed in Section II to supply power for imbalanced two- or three-wire measurements up to 15 A over a frequency range from 30 to 200 MHz. In Section III, a 3-D full-wave simulation with both differential- and common-mode excitations representing the DUT was used to illustrate the effect of the VHF LISN on radiated emissions on a typical test setup for two- or three-wire application. A study of differential- to common-mode current conversion was performed to verify the conversion ratio for an ideal imbalanced termination. In a real test setup, the differential to common-mode current conversion is geometry dependent but not a fixed number. Measurements of a pair of power line communication devices were performed in Section IV to validate the performance of the LISN in a typical test setup and to demonstrate the level of differential- to common-mode current conversion for a real-word application. Discussions are presented in Section V. Finally, Section VI concludes this article.

II. DESIGN OF AN IMBALANCED TWO- OR THREE-WIRE LISN

The following section will introduce the imbalanced two-wire and three-wire terminations suggested by the working group and the literature [10]–[12], provide evidence of the suitability of the proposed impedances, show the characteristics of the actual LISN that was built to use these terminations, and give the value of differential- to common-mode conversion for a practical test setup connected to the imbalanced two wire termination.

A. Imbalanced Two- or Three-Wire Termination

The imbalanced two- and three-wire terminations proposed by the works in [10]–[12] are shown in Fig. 2(a) and (b), respectively. The termination characteristics for two-wire applications were specified as follows.

1) Common-mode impedance ZCM of 150 Ω ± 10% from 30 to 200 MHz, which defines the impedance between the line (L) and neutral (N) wires and the ground-plane, when the line and neutral wires are shorted together.

2) Differential-mode impedance ZDM of 100 Ω ± 10% from 30 to 200 MHz, which defines the impedance between the line and neutral wires when the neutral wire is shorted to the ground plane.

3) Impedance between the line and ground plane of 250 Ω ± 20% from 30 to 200 MHz.

The termination characteristics for three-wire applications were specified as follows.

1) Common-mode impedance ZCM of 90 Ω ± 10% from 30 to 200 MHz, which defines the impedance between the line, neutral, and protective earth (PE) wires (shorted together) and the ground plane.

2) Differential-mode impedance ZDM of 100 Ω ± 10% from 30 to 200 MHz, which defines the impedance between the line wire and the neutral and PE wires, when the neutral and PE are shorted to the ground plane.

3) Tertiary-mode impedance ZTM of 60 Ω ± 10% from 30 to 200 MHz, which defines the impedance between the line and neutral wires shorted together, and the PE wire and ground plane shorted together.

The working group [10]–[12] chose a 150-Ω two-wire common-mode impedance to suppress standing waves in the DUT power. The geometry of a power cable does not allow for easily assigning a common-mode impedance, as the wave structure deviates strongly from a TEM mode wave, but it has been shown that termination impedances in the range of 50 to 200 Ω suppress standing waves well [13]. Although not exact, using a common-mode impedance of about 150 Ω [see Fig. 2(a)] will provide results similar to those observed in [13] and minimal common-mode resonances will occur [13]–[15].

A 90-Ω termination was selected for the slightly thicker three-wire cables [10]. The 100-Ω differential impedance was chosen to mimic the impedance of a typical transmission line (TL) formed by the line and neutral wires [10]. To provide evidence for the validity of this selection, 48 different power cables were measured using a time-domain reflectometer (TDR) (see Fig. 3). Eleven were two wire cables, and 37 were three wire cables.

The impedance value was recorded between the short discontinuity at the beginning of the coax to cable transition and the end of the cable, which was left open. As shown in Fig. 3, a small adapter was made to connect the coax cable to the power cord, which causes a short discontinuity but does not affect the TDR measurement, as we record the differential impedance between the two lines after that discontinuity. The length of the cables is not important as we look at the differential-mode impedance provided by two wires (L and N).

The distribution of the characteristic impedances is shown in Fig. 4. The distribution shows the typical value of the differential impedance is close to 100 Ω, as suggested by the working group [10]–[12]. In the tertiary mode, the line and neutral wires are shorted and driven against the PE and ground (shorted). The line and neutral wires together as a larger “signal” conductor compared to the differential mode case, so the TL impedance is expected to be smaller. A value of ZTM = 60 Ω was chosen for this reason [10].

B. Prototype Imbalanced Two- or Three-Wire LISN

An imbalanced LISN was designed to meet the specifications of the working group. Additional requirements for the designed LISN are listed in Table I. Fig. 5 shows the LISN’s circuit diagram. The capacitor inductor networks in Fig. 5 (L1, C3, L4, and L2, C4, L5) were built to provide the required 50 dB of isolation of the DUT from the mains network at higher frequencies and provide a good connection to the building mains at 50 to 60 Hz. The capacitors C1 and C2 were made sufficiently small to isolate the line and neutral wires from each other and the PE at 50 to 60 Hz, but to allow resistors (R1, R2, and R3) to define the termination from 30 to 200 MHz. While the schematic in Fig. 5 should meet the specifications of the working group, validation is required since parasitics could alter the actual impedances looking into the LISN.

The six impedances specified by the working group could not be measured directly, since they require a floating measurement and different parasitics will be involved in each measurement. To determine the impedances, a combination of measurement and postsimulation was used. Three-port S-parameter measurements were made looking into each terminal of the LISN. A test fixture (see Fig. 6) was built to connect the LISN to the vector network analyzer for the three port S-parameter measurement. The measured S-parameter matrix was imported into advance design system (ADS) [16] to calculate the six specified impedances. The measured impedances and those suggested by the working group are shown in Figs. 7, 8, 9, and 10. The magnitudes of the measured impedances are all within the ranges proposed by the working group [10]–[12]. While the working group does not explicitly specify the phase, the measured phase is within about 30◦ of the ideal 0◦ phase for a resistive termination. More important than the variations in the actual impedance is its impact on the radiated fields. It will be shown in Section III that up to 30◦ variation in phase plus 10% variation in the magnitude of the LISN impedance will cause less than ± 3 dB variation in the radiated emissions, which is acceptable in EMC applications. These results suggest a ± 10% change in magnitude and ± 30◦ in phase is an appropriate limit for defining the impedance of an imbalanced VHF LISN.

C. Impact of Imbalance on Differential- to Common-Mode Conversion

An LISN is a filtering device providing the following:

1) isolation of the DUT from ac power lines and related RF disturbances;

2) a well-defined reference impedance at the LISN DUT port, which is isolated from the main network;

3) the necessary power supply to the DUT.

Looking from the DUT side, the common-mode impedance in the two-wire imbalanced LISN investigated is 150 Ω [see Fig. 2(a) and 13]. However, the common-mode impedance of a balanced LISN is about 50 Ω as seen from the DUT side. For both LISNs, the differential-mode impedance in the two-wire setup is 100 Ω [11], [12].

Testing without an imbalanced termination misses the important differential- to common-mode current conversion that may occur when the product is connected to a real ac mains network. The impact of the imbalanced LISN on differential to common-mode conversion was demonstrated using a 3-D full-wave model of a typical test setup. The model shown in Fig. 11 illustrates a typical radiation test setup [1]. The DUT is represented with a solid metal box (30 cm × 10 cm × 30 cm) located 1 m above an infinite ground plane. The box is connected to a 1.5 m power cable. The wires in the cable were driven with a 1-V differential source with zero-output impedance, as shown in Figs. 12 and 13. The sources were connected to the DUT chassis with a low impedance (10 Ω). This impedance is intended to represent a poor connection of a shield to the chassis. This connection was compared to a 1-Ω connection, which showed that this selection of the connection impedance does not significantly influence the conclusions drawn from the simulation.

A typical power cord geometry was used having a 1.62-mm wire diameter, a 0.89-mm-thick PVC insulation, and a PVC jacket with a diameter of 9.5 mm. The metal to metal distance between the wires was 2.35 mm. This distance forms a TL of about 80 Ω between the line (L) and neutral (N).

Circuit schematics of the full-wave structure with balanced and imbalanced terminations are shown in Figs. 12 and 13, respectively. The balanced or imbalanced terminations were chosen similar to those recommended for the LISN (see Fig. 2). The capacitance between the DUT enclosure and ground is about C ≈ 50 pF, depending on the size of the DUT. This capacitance creates an impedance of about 15 to 100 Ω from 30 to 200 MHz, which is on the order of the 150-Ω common-mode termination RCM, so that nonnegligible common-mode current could flow. Simple models without TLs and an estimated value of the coupling capacitance between the DUT and ground can be evaluated in [11]. Each wire is driven with an identical 0.5-V voltage source if opposite sign is creating a 1-V differential-mode source, which drives differential-mode current. As indicated in Fig. 12, there is no common-mode current when using a balanced termination, whereas the imbalanced termination will cause differential- to common-mode conversion of current (see Fig. 13), which will increase radiated emission. According to the works in [10]–[12], real installations have imbalances, which should be reproduced by the EMC test setup.

To calculate the amount of differential- to common-mode conversion, the full-wave model in Fig. 11 was simulated with an imbalanced two-wire termination (see Fig. 13) over a frequency range from 30 to 200 MHz, as shown in Fig. 14. The differential-mode current reduces with frequency since the 80-Ω TL is terminated into 100 Ω. Of course, for a different cable geometry, the differential-current (blue curve in Fig. 14) might be slightly different but that should not affect the current (< 10% variation) as long as the differential-mode impedance is between 80 to 100 Ω.

The common-mode current is affected by the structural length and fluctuates around 1 mA. The differential- to common-mode conversion can be measured by the ratio of the incident differential-mode power to the resulting power in the common mode as

The differential- to common-mode conversion ratio has been reported to be about −10 to −15 dB for an imbalanced CDNE-M [11]. The actual conversion ratio obtained through full-wave simulation, however, is somewhat geometry dependent and varies from −9 to −25 dB, as shown in Fig. 14. For a threewire application [see Fig. 2(b)], the maximum differential- to common-mode conversion was similarly evaluated to be about −19 dB. The conversion is smaller for three wires than two, because current will return not only via the ground plane, but also in the PE wire. The portion that returns in the PE wire does not contribute to the common-mode current.

III. RADIATED EMISSION USING THE IMBALANCED TWO- OR THREE-WIRE VHF LISN

To demonstrate the impact of the imbalanced LISN on radiated emissions, emissions were simulated using the fullwave model shown in Fig. 11. As shown in Section II-B, the impedances of the actual LISN vary about the ideal values due to unintended parasitics. Simulations were performed using the ideal LISN termination impedances and the realized values, as well as short and open terminations to show performance at the extremes. Table II summarizes all the settings used in the computer simulation technology (CST) Studio Suite. Simulation with the realized termination impedances was accomplished using the cosimulation feature of CST with the measured Sparameters. This feature combines the 3-D full-wave simulation with a circuit simulation or measurement [18] to simultaneously solve for the EM fields and the circuit characteristics. To ensure correct cosimulation, the following simulation procedure was used.

1) The setup shown in Fig. 11 was simulated with the ideal termination impedances represented as lumped elements [see Fig. 15(a)]. This simulation demonstrates the ideal performance of the imbalanced LISN and provides a reference for validation of the cosimulation approach.

2) A second simulation was performed using the ideal terminations with cosimulation [see Fig. 15(b)], where the excitation and the loads were replaced with S-parameter ports. Using the CST design studio cosimulation feature shown in Fig. 16, the excitation was connected to the source port and an S-parameter block representing the loads was connected to the load ports. An S-parameter block evaluated for ideal terminations [see Fig. 17(a)] was used to verify the procedure against the reference result from step 1.

3) After successful validation, the S-parameter matrix measured on the prototype was used to calculate the radiated emissions.

Radiated emissions were also evaluated for short and open terminations, when all the impedances on the termination side were replaced with open or short. The radiated emission was evaluated for all cases at a distance of 10 m. Results were evaluated for both common- and differential-mode excitations.

A. Common-Mode Excitation With Imbalanced VHF LISN

The schematic for the simulation setups with a common-mode excitation and ideal imbalanced two- and three-wire terminations are shown in Fig. 18. The maximum simulated far-field radiation for the three-wire setup with the studied terminations is shown in Fig. 19.

shown in Fig. 19. Strong resonances were observed for open and short terminations. The first peak is around 50 MHz, which is below the quarter wavelength frequency for a 1.5-m wire length, because the 50-pF capacitance between the DUT enclosure and the surroundings. At resonances, the radiation can exceed the radiation from the ideal termination by up to 15 dB. The 90-Ω commonmode termination impedance effectively damps resonances and in that regard seems reasonable with respect to repeatability. These results are in agreement with the previous study on the effect of common-mode impedance on radiation [2]. As shown in Fig. 19, the termination impedance is important at lower frequencies, but is not as significant at higher frequencies due to the increasing electrical length of the wire and the impact of damping due to radiation.

The black and blue curves in Fig. 19 show the results using the cosimulation technique and using standard simulations with ideal terminations. The two curves are nearly identical (< 1 dB difference). The green curve shows the radiated emissions using the measured termination S-parameters from the prototype. Comparing the blue and green curves, the radiated emissions from the real LISN is nearly equal to the radiation seen for the ideal termination case. Similar results were seen for the two-wire common-mode case [e.g., using terminations as in Fig. 18(a) and (b)]. The radiated emissions from the prototype LISN are close to the emissions from an “ideal” imbalanced LISN with less than 2-dB error up to 200 MHz (red curve in Fig. 19).

B. Differential-Mode Excitation With Imbalanced VHF LISN

Fig. 20 shows the differential-mode source excitation and the imbalanced termination in two- and three-wire setups. For both setups, the DM excitation was 1 V with 0-Ω output impedance. A low impedance (10 Ω) was selected to connect the wire to the DUT to represent a moderately poor connection to the enclosure. The radiated emissions from the two- and three-wire setups with differential-mode excitation are shown in Figs. 21 and 22, respectively.

When the ends of the wires on the termination side are open or shorted to the ground plane, the structures are symmetric. In this case, there is little common-mode current flowing in the circuit and very low radiation is observed. Large resonances are shown with open or short terminations because the source impedance is 0 Ω and there is little loss in the system. Resonances would be damped in this case with a larger source impedance. When using imbalanced terminations, there is noticeable differential to common-mode conversion for both the two- or three-wire case, which significantly increases the radiated emissions. As shown in Figs. 21 and 22, the results using cosimulation and using the standard EM simulation with ideal terminations are nearly identical. The difference between the radiation evaluated using the measured S-parameters from the prototype and using ideal terminations was less than a 3.2 dB up to 200 MHz (red curves in Figs. 21 and 22).

C. Tertiary-Mode Excitation With Imbalanced VHF LISN

balanced terminations for the three-wire setup. The excitation is 1 V with zero output impedance. The radiated emissions with a tertiary-mode excitation are shown in Fig. 24. When the wires are open or short, the structure creates a highly resonant system. In the presence of terminations, these resonances will be dampened, regardless of their source. The radiation of the prototype is very close to the radiation with an ideal termination, with less than 3-dB error up to 200 MHz (red curve in Fig. 24).

D. Impact of Termination Condition on Measurement Uncertainty of Imbalanced VHF LISN

The results of radiated emission measurements are affected by the uncertainties listed in [20] and [21]. This section investigates the impact and degree of influence of mains cable termination conditions on the standards compliance uncertainty (SCU) [20], [21]. The SCU is dependent on termination conditions over the frequency range where power cable radiation dominates [20]. Considering the tolerance of the termination impedance, the variation of the emission levels can be calculated, which also allows calculation of the measurement uncertainty influence [20].

The sensitivity of the radiation behavior of the LISN to deviations in the magnitude and phase of the terminating impedance from the ideal case should be analyzed to understand their impact on the SCU. Uncertainty is considered in the CISPR 16-4-1 standard [21]. Here, the average combined standard uncertainty (Uc-scu), including the terminating condition of the main cable, is defined to be

where CISPR/TR 16-4-1 specifies [19], [20] the following.

1) Uc,MIU, combined measurement instrumentation uncertainty, of 2.5 dB.

2) Ua, uncertainty from the main cable arrangement, of 3.5 dB. This value will depend on the termination conditions.

3) Uc, uncertainty in the operating condition of DUT, of 1.7 dB.

4) Ub, the uncertainty in termination conditions.

Assuming a rectangular probability distribution for the uncertainty of the cable terminating conditions, which is considered in CISPR 16-4-1 [21], the uncertainty in the terminating condition is given by [20]

where Emax and Emin are the maximum and minimum electric field strengths in dB µ V/m, respectively. If we consider the maximum deviation due to the termination condition of the prototype up to 200 MHz to be 3.5 dB (see Fig. 22 for a three-wire termination with DM excitation), the uncertainty in the terminating condition Ub is only 1 dB. Using (2), the average combined standard uncertainty (Uc-scu) is 4.7 dB. The expanded standard uncertainty Uscu, VHF-LISN is [20]

Compared to the 50-Ω LISN in [20] with an expanded standard uncertainty Uscu, VHF-LISN = 12˜dB, the expanded standard uncertainty of the imbalanced two- or three-wire VHF LISN has been improved by about 2.5 dB. Compared to the 15.5-dB uncertainty defined in CISPR 16-4-1 [21], the SCU for the imbalanced two- or three-wire VHF LISN is improved by about 6 dB. It should be noted that only a single device was studied here, and results may change with other devices.

IV. VALIDATION THROUGH MEASUREMENT

The effect of the differential- to common-mode conversion was investigated using a power line communication device. The goal was to investigate the impact of termination conditions on emissions with a DUT that uses a strong differential-mode signal to transmit data over power lines [11], [12]. The test used different termination conditions, a balanced LISN, an imbalanced LISN, and no LISN. A balanced LISN (see Fig. 1) was prototyped to compare with the imbalanced LISN. The balanced LISN had a 50-Ω impedance on each line with less than 1.5-Ω variations in magnitude and less than 5◦ variations in phase over the frequency range from 30 to 200 MHz.

A block diagram of the measurement setup inside the semianechoic chamber is shown in Fig. 25. The two DUTs are HD power line adaptors (PLA5456), which communicate with each other through power lines. The measurement setup is shown in Fig. 26. The DUTs and LISN are mounted on the floor such that the power cable produces a loop with the maximum radiated emissions toward the antenna. A personal computer (PC) was needed to communicate with the DUT. To generate the highest differential-mode current, the DUT was operated under its maximum data rate. The measurement was performed for both horizontal and vertical polarizations and with 1- to 4-m scan heights of the antenna. The table was also partially rotated to capture the maximum radiation.

The goal was to show the differential- to common-mode conversion by using an imbalanced LISN, but also to show the impact of connecting the LISN to different power nets, as well as to show the impact of the power nets on emissions when no LISN was used. Connecting the LISN to different power nets helps to show if it has reproducibility issues. Different power networks were created by adding a soldering iron, a linear dc power supply, different wires with terminations, such as 2 nF, power cords, and strip lines, to the outlet inside the chamber.

Changing the power net before the LISN should have no effect, as the LISN isolates well. With different termination impedances, however, the radiation should change noticeably if no LISN is used. While different emissions are expected from a balanced or imbalanced LISN, both are expected to generate somewhat stable curves because both LISNs isolate the DUT from the power net. Higher radiation is expected using an imbalanced LISN rather than by using a balanced LISN, since the imbalanced LISN converts differential-mode current into common-mode current. Radiation results for all power networks and using three different termination conditions (balanced LISN, imbalanced LISN, and no LISN) are shown in Fig. 27. When both power line communication devices are ON, the broadband signal below 80 MHz is representative of the data transfer from the DUT. The DUT has no differential-mode energy above 80 MHz. Some observations are (a) when not using an LISN, the radiated emissions vary by up to 12 dB, since the termination is not controlled. (b) with a balanced or an imbalanced LISN, radiation has less than 3-dB variation, because the LISNs isolate the network and provide a well-defined termination. (c) the conversion with the imbalanced LISN is as high as 12 dB. (d) the imbalanced LISN generates emissions that are close to the worst of the measured emissions when connecting directly to the power networks, and (e) both LISNs have no reproducibility issues.

Neither impedance, nor conversion, has been characterized for the chamber used for measurement. Therefore, the observed variation in radiated emission is expected to be large ΔE > 10 dB. However, both balanced and imbalanced LISNs have controlled terminations and will not cause reproducibility problems because the data have less than 3-dB variation for different power networks. In general, the data show that for a device that has a strong differential-mode current, the imbalanced LISN brings the emissions to a more realistic level. The result from the balanced LISN ignores the differential- to common-mode conversion and gives unrealistically lower emission.

The conversion of course should correlate to the currents on the wires. The common-mode and differential-mode currents have been measured with a F65 current clamp at a few points along the cables. The maximum current has been captured and the conversion was calculated as the difference between the maximum common-mode current when the cable was terminated with balanced and imbalanced LISNs.

Similarly, the radiated emission conversion was calculated as the difference between the maximum radiated emission when the cable was terminated with balanced and imbalanced LISNs. Fig. 28 shows differential-mode to common-mode conversion, which is calculated from both current (blue curve) and radiated emission (red curve) measurement using balanced and imbalanced LISN. As shown in Fig. 28, the conversion calculated from radiated emission and the common-mode current are quite similar, i.e., this plot validates the conversion ratio with two different quantities, e.g., current, and radiated emissions. Above 80 MHz, the observed differences between the common-mode current for both balanced and imbalanced LISNs are almost zero because the DUT has no transmit energy. At the lower frequency band, the conversion is as high as 12 dB for both radiated emission and common-mode current.

V. DISCUSSION

Imbalanced LISNs can be designed for different target impedances. The LISN analyzed in this article was designed for a 150-Ω common-mode impedance, as suggested in the literature [10]–[12]. This impedance can strongly attenuate cable resonances [13]. Since actual power networks show strong resonances, one would underestimate the actual radiation at these frequencies. An alternative would be to design the LISN for a 25-Ω common-mode impedance. While this smaller impedance would strongly increase the radiation at resonances, there is no certainty that the resonances would occur at the same frequencies in the real installation since the actual power line impedances are unknown. A far-reaching design of an LISN might allow one to adjust the common-mode impedance along the Smith chart to identify the worst-case common-mode impedance for a given DUT. The impact of common-mode impedance on the radiation at resonances should be investigated in future.

Alternatively, it may be worthwhile to further study the PE line impedance in a variety of application areas, for example, in an urban area or in light industry area, and then adjust the LISN impedance according to the application.

VI. CONCLUSION

An analysis of an imbalanced two- or three-wire VHF LISN was conducted in terms of its mode conversion and termination impedance. It was demonstrated that an imbalanced termination impedance provides a specified degree of conversion from differential to common mode, which can lead to more representative radiated emission test results. To ensure spectral emission control, an imbalanced LISN is needed. An imbalanced two- or three-wire VHF LISN was prototyped. The impedances in the prototype had less than 10% error in magnitude and 30◦ in phase compared to the impedances for an ideal imbalanced LISN, as specified by the working group. A 3-D full-wave simulation was performed to investigate the maximum radiation of a twoor three-wire setups using an imbalanced termination. It was demonstrated that the performance of the prototype leads to less than 3.5-dB error as compared to an ideal imbalanced LISN. In EMC applications, this error threshold is acceptable. It is therefore suggested that the impedance of an imbalanced VHF LISN vary by less than ± 30◦ in phase and ± 10%. For the main cable termination, the standard compliance uncertainty has been considered in CISPR 16-4-1 to be 15.5 dB. This uncertainty has been improved to about 9.5 dB for the proposed prototype. The differential- to common-mode conversion for an imbalanced termination was measured with two power line communication device to be as high as 12 dB considering both current and radiated emissions. Using different power nets inside an anechoic chamber, it was demonstrated that the chamber-tochamber reproducibility will be much better if an imbalanced LISN is used in every chamber.

Posted on

PB2021.10 CDM继电器POGO先接触CDM和CC-TLP脉冲的研究

下载PDF – CDM继电器POGO先接触CDM和CC-TLP脉冲的研究

STUDY OF CDM RELAY POGO-CONTACT FIRST CDM AND CC-TLP PULSES

Abstract – The recently proposed RP-CCDM testing method is tested alongside the more established CDM and CC-TLP methods on two test ICs to assess the RP-CCDM’s efficacy as an alternate test method. High bandwidth analysis of field induced CDM spark events is presented to evaluate higher frequency components of the current.

I. Introduction

A CDM event occurs when the pin of a charged device approaches an external metal object such that the potential difference exceeds the breakdown voltage of the air gap between them. CDM is one of the most common ESD threats in modern manufacturing and usage environments. The current industry standard testing method is the Field Induced CDM (CDM) method governed by the ANSI/ESDA/JEDEC JS-002 standard [1]. Current CDM testers are plagued with repeatability issues due to the variable spark resistance of the air discharge making the practice difficult to standardize [1, 2]. Additionally, decreasing CDM testing voltages increase the pulse-to-pulse variability of the air discharge, causing concern over the ability to meaningfully classify devices at lower voltages [3]. This is becoming increasingly problematic as the necessity for classification at lower levels is becoming greater with advances in IC technology [2]. Several contact-first CDM methods where a CDM current is induced into the pin through a more controllable method, such as the CC-TLP, LICCDM, and RP-CCDM, have been introduced in an attempt to solve the issue of pulse variability [4, 5, 6].

This work presents a correlation study between the CDM, RP-CCDM and CC-TLP testers on two devices with well-known CDM failure levels and failure mechanisms. The devices are subjected to a series of RP-CCDM and CC-TLP tests with multiple risetimes. The study aims to evaluate the efficacy of the RP-CCDM method and gain insight into the correlation of RP-CCDM and CC-TLP to better understand their potential as replacements for CDM susceptibility testing.

II. CDM and CC-TLP Tester Configurations

A. RP-CCDM Tester

The RP-CCDM, or Relay Pogo-Contact First CDM, is a design of the CDM discharge head that allows the use of a repeatable relay discharge while largely preserving the design parameters of the JS-002 standard. Figure 1 shows a cross section of the RP-CCDM head.

As shown in Figure 1, the RP-CCDM uses the field charging method and a similar discharge path to the one specified in the JS-002 standard. To charge the device, the pogo pin of the RP-CCDM ground plane is lowered to contact the DUT pin, then the field plate is brought to the specified charge voltage. To discharge, the reed switch is closed and the current primarily flows up the pogo pin, through a high bandwidth 1 Ω resistor, and returns via the ground to field plate and DUT capacitances. A more detailed testing procedure for the RP-CCDM is presented in [6].

The RP-CCDM prototype head used for stressing devices in this study was found to adhere to the discharge waveform parameters specified in the JS-002 standard. The RP-CCDM prototype was also found to have a strong correlation in peak currents to the peak values measured with a CDM head across a range of coins with varying CDUT values.

B. ACRP-CCDM Test Setup

The RP-CCDM and CDM test are different in two key aspects that could be the source of correlation issues. First, the RP-CCDM spark takes place in a controlled environment free of air. This difference results in a much more reproducible spark environment that reduces the variability of the peak current when compared to air discharge CDM and enables testing below 100 V [6]. The altered spark environment may also influence the risetime and result in less damping of the system due to a smaller series spark resistance value. Second, the geometry of the RP-CCDM head is different from that of the CDM to accommodate the reed switch. Specifically, the pogo structure is no longer uniform in thickness and longer than in CDM, which will affect the inductance of the discharge path. To further investigate the role of these two variables the “Always Closed” RP-CCDM (ACRP-CCDM) test method was implemented. This test method uses the existing RP-CCDM test setup but alters the testing procedure to close the reed switch in the pogo pin prior to descent such that a CDM-like air spark is created. This method removes the reed switch spark variable and reveals differences between CDM and RP-CCDM based on the test head geometry alone.

To evaluate differences in the rising edge, or any other part of the current waveform, RP-CCDM, ACRP-CCDM, and CDM tests were performed using a 23 GHz bandwidth Tektronix MSO72304DX oscilloscope and a low loss measurement chain. The insertion loss of the measurement chain, shown in Figure 2, was less than 2 dB up to the 23 GHz measurement bandwidth of the oscilloscope. The same model of disk resistor was used for the construction of both heads with the resistive sheet facing away from the pogo-pin, this type of disk resistor has been characterized up to 26.5 GHz in [7]. The DC resistance value was used for current measurement scaling.

Figure 3 displays the five highest peak current pulses captured from a set of fifty discharges on a small JS-002 verification module at TC500. These pulses represent the lowest spark impedance discharges for each tester. The initial rising edge of the CDM and RP-CCDM pulses is observed to be similar, although the CDM rising edge reaches a higher peak in the first 50 ps and the RP-CCDM reaches a higher peak in the first 80 ps. The ACRPCCDM current measurement has a rising edge more similar to that of the CDM pulse, possibly indicating a relationship between the rising edge and the air spark event, whereas for the rest of the measurement duration the ACRP-CCDM pulse matches the curve of the RP-CCDM current indicating a relationship with the test head geometry. The risetime of the RP-CCDM does not exhibit any characteristics that indicate a faster risetime than its air spark counterparts. The RP-CCDM slew rate may be faster on average, however, due to degradation in the CDM slew rate during discharges with high series spark resistance. Figure 5 displays the frequency spectrum of each pulse shown in Figure 3.

In [7], it was observed that the high frequency content seen in the CDM and RP-CCDM spectrum is likely related to the pogo pin length and the disk resistor. As shown in Figure 5, the high frequency content observed in the RP-CCDM spectrum is quite similar to the content seen in the ACRP-CCDM spectrum, indicating that the RP-CCDM relay spark does not introduce any unwanted resonances. Whether the current measurements in Figure 3 and the structure resonances seen in Figure 5 are indicating the true current magnitude that is traveling though the IC pin during a CDM stress is not yet fully understood but is currently being investigated. The presence of the high frequency current components that occur in field induced CDM events could be an important factor in determining the efficacy of alternate test methods on sensitive ICs.

C. CC-TLP Test Setup

The CC-TLP method utilizes a VF-TLP pulse into to a single IC pin and a capacitively coupled return path to create a CDM equivalent stress [4]. CC-TLP is a contact-mode tester and as such has the advantage of having much lower pulse to pulse variability than a standard CDM test with an air spark. The CC-TLP method also allows correlation between peak current levels and pulse width settings to CDM stress parameters which can be used to evaluate CDM type failure modes [8, 9]. In this study, two CC-TLP setups were used for testing. The first tester used to perform testing at IFX, uses a circular ground disk with a diameter of 5 cm. The length of the probe tip is adjusted to 0.3 mm [10]. A TLP system with 1 ns pulse width and 100 ps risetime is connected as excitation source. The second CC-TLP tester, manufactured by and used to perform testing at ESDEMC, uses a test head with a square, rather than circular, ground plate the same size as a JS-002 CDM tester’s ground plate. The length of the probe tip is adjusted to 0.5 mm. The bandwidth of both CC-TLP measurement chains were limited by the pick-tee cutoff at approximately 10 GHz. Both testers integrate S-parameter compensation of the measurement chain in software. The same pulse parameters were used for both testers. A “dummy” device was used to determine the charging voltage necessary to achieve the desired peak current on each pin of each device tested.

III. Correlation Study

A. Device Information

Two different test devices are used for the correlation study of RP-CCDM, ACRP-CCDM, CC-TLP and CDM in terms of the failure level. Both devices are designed in 130 nm CMOS technology. Device A is packaged in a TSSOP, device B as eWLB. The expected failure mode is the excess of a critical potential level leading to gate oxide damage at one or more transistors. The failure mechanism of device A is a GOX failure triggered by a cross-domain issue and is located at an internal interface in the core. Device B shows several GOX failures and increased IDDQ currents after the damage occurring at the transistors on the edge of the digital core.

B. Transmission Line Connected Pins

As observed in measurements on the JS-002 verification modules, the peak current of the RP-CCDM and CDM testers was measured to be nearly identical on a reference connected pin of the device as seen in Figure 6. However, this relation was found to not hold across all pins on device B.

The most sensitive pins on device B are high-speed I/O pins connected to the die via impedance controlled, transmission line (TL), traces, such as shown in Figure 7.

In Figure 8 two curves of a TDR measurement in a CC-TLP setup are shown. The probe tip of the CC-TLP test head is connected to the chip, so that the current path to the die can be analyzed such as shown in [11]. Once the current wave reaches the die, the capacitance formed by the package and die to the ground disk of the test head is charged and marks the end of the transmission path. This method enables to measure delay times of single pins. In case of a pin with a corresponding ball in the direct vicinity of the die pad the delay due to the transmission path can be neglected (Fig. 8, green curve). For the second pin the connected transmission line forms a stable impedance for about 120 ps (Fig. 8, blue curve).

The stress observed on these pins is paramount to determining the stress that the device can withstand. However, due to the high variability of air discharge CDM testing, it can be difficult to evaluate the difference between testers on these pins after a typical CDM validation test with only three discharges per polarity.

C. Peak Current Comparison of Pin Types

To evaluate these pins more accurately, a 100-pulse test was performed by stressing a reference connected pin and a TL pin 100 times each. All testers were tested at a 500 V field charge voltage to prevent any spark differences that may occur if the JS-002 voltage factor method was incorporated. The pogo pins and dielectric surface were cleaned with isopropyl alcohol prior to testing and the testing was performed below 10% relative humidity to minimize peak variation due to the air spark. Due to the charge distribution over the whole chip and high current levels with ESD devices operating in the on-state, no difference is expected in the discharge waveforms from before failure to after failure of the device. An additional CDM tester head with a replaceable pogo pin was incorporated to evaluate the influence of various pogo lengths on the observed discharge peak. This new test head was used alongside the RP-CCDM and CDM heads used in all device testing. The CDM head used for device testing is indicated as “large diameter” since it has a diameter of 1.5 mm compared to the new test head’s 0.4 mm pogo diameter. Table 2 displays the maximum peak current measured within the 100-pulse test for each setup and the relative percentage of the TL pin peak current to the reference connected pin peak current.

As can be seen in Table 2, there is a correlation between the length of the pogo pin and the discharge current ratio between the TL connected pin and the GND pin. For a given pre-charge voltage (with voltage factors applied such that the RP-CCDM and CDM peak currents match on JS-002 verification modules) where a CDM stress induces 5 A peak current on the studied TL pin, the RP-CCDM stress will induce a 5.7 A peak current. This additional current can be clearly seen in the measured currents shown in Figure 9, which was taken during a qualification test of device B. The cause of the increased peak current of RPCCDM with respect to CDM for the same pre-charge voltage on TL pins can be explained by the input impedance of the CDM head. Figure 10 displays the input impedance of the CDM heads used in Table 2 as measured in [6], denoted as ZDUT. Due to higher input impedance in the 600 MHz to 2 GHz range, where the majority of the spectral content is contained (Fig. 5), a larger reflection back into the device trace will occur in the case of the RP-CCDM. As discussed in [12, 13], the stress the die experiences is a result of the reflected pulse off this discontinuity. As a result, the stress a TL connected I/O receives will be greater for a CDM head with a higher input impedance, given a matching peak amplitude on a calibration coin.

D. Simulation of Transmission Line Pins using ZDUT

To determine if the measured ZDUT values alone could predict the difference, a simulation using the measured ZDUT data was done in ADS by Keysight. A simplified circuit model, developed in [12], was adopted to represent a CDM event on a TL pin where the current must travel through the impedance-controlled trace and encounter an impedance discontinuity at the pin/pogo-pin interface.

As can be seen in Figure 13, the ADS simulation produces the same relationship in measured current as the measured data. The current measured using the measured RP-CCDM ZDUT to represent the test head structure results in a higher current measurement on the TL connected pin. Figure 14 shows the current measured on the die side of the transmission line and indicates an increased current peak with the RP-CCDM head. Further development with a less simplified model of the TL pin case is necessary to determine the precise stress difference that occurs due to this effect.

IV. Failure Analysis Results

A. Device A Failure Results

Device A was tested using RP-CCDM, CDM, and CC-TLP testers. To test if that the failure levels of device A are risetime dependent, CC-TLP tests were performed using 100 ps and 300 ps risetimes. The determined failure levels of the device A are shown in Table 3 and Table 4. The devices were stressed at increasing test conditions until failure. The recorded withstand current indicates the highest current that all tested devices were able to withstand. Failure analysis on device A was carried out via DC leakage testing.

Table 3 and Table 4 display the failure levels for the device A. The RP-CCDM and CDM were observed to correlate well on this device, inducing failures at TC750. Additionally, CC-TLP setups at ESDEMC and IFX both induced failure at 8 A. Figure 15 displays a comparison of each tester’s discharge waveforms recorded at the failure threshold of device A. As seen in Figure 16, a clear jump in the leakage current is evident for each device stressed at its failure threshold.

B. Device B Failure Results

Device B was tested with the RP-CCDM and ACRP-CCDM at test conditions of 400 V, 500 V, and 625 V. Additionally, tests with CC-TLP setups were performed at 4 A, 5 A, and 6 A with a 100 ps risetime and 6 A, 7 A, and 8 A with a 300 ps risetime.

Failure analysis on device B is carried out via DC leakage testing and verified via IDDQ testing. The failure is expected for pre-charging voltages higher than TC500 on CDM and located on the edge of the digital core. The IDDQ analysis measures the current consumption in the quiescent state on 200 vectors in the digital core.

The quiescent current into VDD for all vectors is below 100 uA in case of an unstressed reference device. Slight deviations in this range are traced back to normal variations. A significant increase of the current compared to the reference device indicates a gate-oxide failure on the edge of the digital core. Significant deviations between vectors in the IDDQ sweep are also an indication of failure on the edge of the digital core.

Table 5 and Table 6 display the failure levels for device B. Figure 17 – Figure 20 display the IDDQ readouts indicating the failure thresholds for each tester.

As shown in Table 5, the RP-CCDM induced failures below the TC500 withstand voltage of the device on a CDM tester. Figure 21 displays the measurement of the largest amplitude stress discharge for the CC-TLP, ACRP-CCDM, and RP-CCDM stress sets at 5 A, TC500, and TC500, respectively.

As shown in Figure 21, the ACRP-CCDM and RP-CCDM have similar pulse shapes and amplitudes on the sensitive I/O pin studied previously and produce failures at the same test condition. The RP-CCDM IDDQ sweep shows a more larger failure, which may be due to the more controlled spark environment and therefore slightly higher peak currents. Both the RP-CCDM and ACRP-CCDM testers produce increased amplitude pulses on TL pins when compared to the CDM tester due to the higher input impedance as discussed in detail in section III. The failure of both the ACRP-CCDM and RP-CCDM to correlate to the CDM at TC500 indicates that the geometry of the test head is likely responsible for the early failures on device B, rather than the spark event in the relay environment. The geometry contributes to a higher stress in the case of ACRP-CCDM and RP-CCDM due to the TL pin effect studied in section III.

As shown in Table 6, the peak current failure thresholds of both CC-TLP testers correlated well with each other by producing repeatable failures at 5 A peak current with a 100 ps risetime pulse and at 8 A with a 300 ps risetime pulse. It was observed during the correlation study that a failure at 5 A could not be reliably achieved until the risetime of the incident TLP pulse at the CC-TLP probe port was slightly decreased and approached 90 ps on the ESDEMC tester. This observation reasserts that the risetime of the stress is a critical stress parameter of device B and that the exact risetime of the incident TLP pulse is an important factor to consider when correlating CC-TLP systems.

V. Conclusions

In this study, the RP-CCDM test method was evaluated in comparison to the CDM and CC-TLP test methods using high bandwidth measurement and spectrum analysis, input impedance measurement and circuit modeling on TL pins, and device failure analysis on two devices.

It was shown that a longer pogo pin can induce a larger amplitude current discharge on a TL pin, given a matched peak current on a reference pin, due to the larger input impedance seen at the pogo-pin/device pin interface. This effect was replicated using a simplified model in ADS.

The RP-CCDM showed perfect correlation to CDM stress tests on one device, but consistently showed failures at a lower threshold on a second device. Although construction and excitation sources of both CC-TLP testers are different, they correlated well with the failures induced by the CDM and were helpful in indicating whether risetime was a critical stress parameter of the test devices.

The RP-CCDM was also used to perform air discharge tests, when the relay in the pogo-pin was closed during the entirely of the test and resulted in failure levels that matched RP-CCDM results. These results indicate that the RP-CCDM structure is likely responsible for the early failures on the second device due to the increased currents induced on TL pins. Analysis of the spectra between CDM (air spark) and RP-CCDM (relay spark) suggest that there is no significant increase in spectral content other than that caused by as more stable, low impedance spark. This observation suggests that the RP-CCDM may represent a “worst-case” air spark, that is the spark that would occur between two very clean surfaces at low relative humidity. More testing and statistical analysis of the RP-CCDM is necessary to make a conclusion about the “worst-case” analogy.

VI. Acknowledgments

The authors would like to thank Dr. Kai Esmark of Infineon Technologies AG for providing the testing devices, for his support regarding the failure analysis and for sharing his wide knowledge of ESD, and in particular, of CDM. The authors would also like to thank Michael Reardon of ESDEMC for his assistance and input during the CC-TLP testing portion of this study.

Posted on

PB2021.08 松散电接触对无源互调干扰的影响机理分析

下载PDF – 松散电接触对无源互调干扰的影响机理分析

摘要 抑制无源互调干扰是确保新一代移动通信系统安全、稳定和经济运行的重要前提,也是推进我国电信基础设施共建共享的重要保证,对无源互调干扰的产生机理进行分析是抑制其干扰产生的最根本性手段。本文综合性地阐述了金属松散电接触对无源互调干扰的影响机理,包括金属电接触表面的微观特征分析、松散电接触等效电路模型建立、松散电接触面电流密度和阻抗等电特征量对互调干扰作用机制等内容。理论建模、软件仿真以及实验测试表明:松散电接触导致增大的面电流密度与接触阻抗是产生无源互调干扰的直接原因。

关键词 无源互调干扰、松散电接触、同轴连接器、接触阻抗、新一代移动通信系统

引言

无源互调干扰 (passive intermodulation, PIM) 是指两个或两个以上的载波信号在通过无源器件时由于无源器件的微弱非线性所导致的一种谐波干扰现象 [1] . 所谓无源器件是指微波电路或通信系 统中的连接器、衰减器、耦合器和馈线等一类无需功率源驱动工作的器件关于无源互调干扰的产生过程可参见如图 1 所示的简化模型在无源器件的输入端施加一双载波信号假设其载波角频率分别为 ω1, ω2, 由于器件的非线性影响在该器件的输出端将产生新的无源互调干扰频率成份其中无源互调的阶数 N 定义为 N = |m| + |n|; 式中 m, n 分别为 ω1, ω2 的系数例如 2ω1 − ω2, 2ω2 − ω1 均表 示三阶无源互调干扰, 3ω1 − 2ω2, 3ω2 − 2ω1 均表示五阶无源互调干扰其他阶数的无源互调定义依次类推.

关于新增无源互调频率成份的具体来由及其量级大小的表述方式可参阅文献 [2], 此处不再详细 描述观察图 1 所示的无源互调产物可以发现三阶互调频率成份距离载波频率 ω1, ω2 不易设计滤波器滤除且其量级高对载波信号干扰最强因此三阶互调成份是抑制无源互调干扰的重点故本文的研究工作也主要围绕三阶无源互调干扰展开.

1.1 无源互调干扰的危害

早些年由于地面移动通信系统的功率和频率密度相对较低因此关于无源互调干扰的报道常 见于远洋船舶、卫星等需要进行大功率甚至超大功率通信的应用场合中[35] . 近年来随着地面移动通信系统的工作功率、通信频带宽度的不断提高以及电信基础设施共建共享水平的不断深入新一 代移动通信系统对无源互调干扰的敏感程度越来越高具体可表现为以下两个方面.

1.1.1 无源互调干扰对电信基础设施共建共享的危害

2013 年中华人民共和国工业和信息化部和国务院国有资产监督管理委员会联合出台了《关于推进电信基础设施共建共享的实施意见》并倡导成立了 “中国铁塔股份有限公司”, 大力推进我国的电信基础设施的共建共享水平 [6] . 电信基础设施的共建共享可带来 3 方面好处可避免电信基础设施的多次重复投资和资源耗损有利于网络资源的合理配置便于施工维护和降低运维成本 [7]; 但不同的电信运营商 (例如中国电信、中国移动、中国联通和不同代通信系统 (例如: 2G/3G/4G/5G) 共享同一电信基础设施将带来严重的多系统间无源互调干扰问题[8] . 此处以中国移动与中国电信、联通两大电信运营商的 2G 通信频段为例进行说明其系统间无源互调干扰如表 1 所示 1 中仅仅列举了中国移动与中国电信、中国移动与中国联通在 2G 频段内相互之间的无源互调干扰忽略了中国电信 与中国联通之间在 2G 频段内的无源互调干扰也忽略了中国移动单个运行商的不同代通信系统之间 的无源互调干扰更是忽略了不同电信运营商多代通信系统之间的无源互调干扰因此在电信基础设施共建共享带来诸多便利的同时各通信系统间的无源互调干扰是亟待解决的难题迫切需要从根本上抑制无源互调干扰的产生.

1.1.2 无源互调干扰对新一代高功率通信系统的危害

第五代移动通信系统的工作功率约为第四代移动通信系统的 3 [9] , 而无源互调干扰的量级 与通信系统的工作功率成正比例关系那么意味着在 2G/3G/4G 等传统移动通信系统中原本相对微 弱、不易被通信设备接收端捕获的无源互调干扰信号其量级在新一代移动通信系统中将成倍数增长本小节以移动通信系统中使用最为广泛的 SMA 同轴连接器为例对其输入功率及其在此输入功率条件下对应产生的三阶无源互调值进行测试其结果如表 2 所示依据表 2 的分析结论当输入功率增加约 4 倍时其对应的三阶无源互调干扰值将增加约 100 换言之同等条件下第五代移动通信系统的无源互调干扰将比第四代移动通信系统增加约 100 此特征亦要求在新一代高功率移动通信系统中必须从根本上抑制无源互调干扰的产生.

综上所述不管是新一代移动通信技术的广泛推广还是电信基础设施共建共享的顺利实施 要求从根本上抑制互调干扰的产生其关键还在于明晰无源互调产生的确切机理.

1.2 松散电接触影响机理分析的现实需求

无源互调现象最早于 20 世纪 60 年代在远洋船舶卫星通信系统中被发现多年的研究积累使得在高空、大功率通信系统 (如卫星通信等国内外有不少成功应用的先例 [10, 11] . 近年来随着地面电信基础设施共建共享的实施以及新一代移动通信系统的功率、频率和元器件集成度的不断提高新一代移动通信系统的无源互调干扰问题成为一个新兴的研究领域例如: 2015  6 首届移动通信无源互调讨论会在西安交通大学举办; 2015  8 在杭州召开了移动通信多系统合路无源互调 ( 统间互调测试的首次研讨会此类研讨会很好地促进了我国移动通信无源互调干扰问题的交流和科 学研究水平但由于此领域研究的开展时间不长仍有较多问题未能涉及松散电接触便是其中之一同时不同于高空卫星通信设备近乎苛刻的生产制造环节和终生免维护性地面移动通信系统在使用 过程中通常需要多次调试和周期性维护因此易造成金属连接器件的疲劳和电接触表面的轻微形变同时空气环境中金属的氧化、硫化与污染现象都使得电连接故障难以完全避免.

此外不同于传统移动通信系统新一代移动通信的频率成倍数增长例如: 2G/3G/4G 等传统通信系统最高工作频率均不足 3 GHz,  5G 通信系统的实验频率为 28 GHz (北美), 那么意味着对信号传输载体器件或电路的电连接情况提出了更加严格的要求传输信号的频率越高金属的趋肤效应会 使信号电流越来越集中在传输载体的表面例如金属铝的趋肤深度与频率关系如表 3 所示当金属铝传输的信号频率从 103 Hz 增加到 109 Hz 实际传输信号在金属铝表面深度从 2.59 mm 降低到 2.59 µm, 对于 5G 移动通信系统常采用的 28 GHz 实验频率金属铝的有效信号传输深度仅为 0.49 µm. 这说明高频率产生的趋肤效应使得信号电流在传输器件的实际有效区域十分狭小那么意味着信号 传输器件的轻微松散电接触对传输信号完整性的影响将是致命性的.

因此本文专门针对松散电接触的无源互调影响机理开展研究具体的组织结构如下 2  先对电接触金属表面的微观特征结构进行分析然后从无源互调的产生角度建立良好 (紧凑电接触 电路模型以第 2 节的分析结论为依据 3 节从宏观和微观两个角度分别建立松散电接触的稳态 和动态模型指明发生松散电接触时金属交界面的电特征量将如何变化 4  5 通过软件仿真与实验测量相互佐证本文所提出的研究结论 6 节对全文进行了总结.

紧凑电接触无源互调影响分析

同轴连接器作为微波电路中使用最为广泛的元器件之一是移动通信系统中产生无源互调干扰的关键原因 [12] . 其应用环境的氧化与硫化现象、工业制造的微小误差、多次重复使用导致连接器交界面的轻微变形以及不恰当连接扭力都会造成同轴连接器发生松散电接触现象因此本文以同轴连 接器为研究对象来分析松散电接触的无源互调干扰产生机理.

2.1 金属电接触表面微观结构特征

参照图 2(a)  (b), 一对同轴连接器通常由母头和公头两部分组成 [13] . 外力通过扭力扳手旋转公头的螺纹控制公头和母头的连接程度当扭力扳手发出 “滴答” 声后表示公头和母头已实现紧凑连接此刻则停止旋转扭力扳手当存在松散电接触时 (如图 2(c)), 同轴连接器的公头和母头不能完全对齐进而导致同轴连接器电连接的真实接触面积小于理论接触面积使同轴连接器交界面的电特征 参数发生改变为明晰松散电接触的电特征量变化与无源互调干扰的内在关联本小节首先对金属电接触表面的微观特性进行分析然后建立金属紧凑电接触等效模型为后继研究铺垫基础.

参照图 3(a), 在微观视觉下同轴连接器的金属表面并不是绝对的光滑而是由许多微小凸起尖峰和凹陷区域组成[14] . 同时同轴连接器曝露在空气环境中其表面会形成一层绝缘膜层 (氧化层、硫化 物等污染物统称). 那么当图 2 所示的连接器公头和母头在外力作用下形成物理连接时金属接触面中一部分高度较高的凸起尖峰会刺穿绝缘膜层形成直接的金属 – 金属 (metal-metal, MM) 型连接 一部分高度适中的凸起尖峰没有刺穿绝缘膜层进而形成金属 – 绝缘膜 – 金属 (metal-insulator-metal, MIM) 型连接最后一部分高度较低的凸起尖峰或凹陷区域没有接触到绝缘膜层对连接器传导情况没有任何影响所以此部分情况不做考虑. MIM 型与 MM 型的接触机理模型如图 3(b) 所示需要注意的是在建立如图 3(b) 所示的接触机理模型时进行了一种等效转化处理将两个粗糙程度近 似相同的金属接触面等效为一个绝对光滑的金属接触面和一个粗糙程度在原来基础上加大两倍的金属接触面 [15] . 那么等效的 MIM 型和 MM 型接触机理模型可用图 3(b)(2) 进行描述.

 3(b) 金属接触表面以及覆盖的绝缘膜层采用弯曲实线表示电流线方向及其路径采用虚线 箭头表示此外 3(b)(1) 也给出了 MM 型接触和 MIM 型接触两种连接类型的电流传导示意图 发生 MM 型接触时微小尖峰刺穿绝缘膜层形成直接的金属与金属之间的连接电流直接由接触表面 A 流向接触表面 B; 当发生 MIM 型接触时微小尖峰没有刺穿绝缘膜层换言之接触表面 A 的电 流是透过绝缘膜层而到达接触表面 B 氧化物和污染物形成的绝缘膜层是一种非线性材料因此 MIM 型接触是导致无源互调干扰的一个重要原因 [16].

2.2 紧凑电接触等效电路模型

综上所述无论是 MIM 型接触还是 MM 型接触在微小尖峰形成的连接结附近处电流线都会 发生收缩现象导致电流线路径变长和电流密度变大将产生收缩电阻假定 MM 型接触产生的收缩 电阻为 Rmm, MIM 型接触产生的收缩电阻为 Rmim. 此外 MIM 型接触中除收缩电阻外绝缘膜层还会有额外的电阻 Rf 和电容 C f . 同时如图 3 所示两金属表面相互连接时还存在较多的未接触区域且该未接触区域为两金属表面绝缘膜层的狭小缝隙根据其电学特性可将未接触区域等效为一 电容 C v. 那么 3(b) 所示的紧凑接触机理模型可用图 4 所示的电路模型进行等效.

 4 参量: Rtf , C tf  Rt−mim 分别表示同轴连接器整个理论接触面积内所有的 MIM 型接 触总的绝缘膜电阻、绝缘膜电容以及收缩电阻, Rt−mm 表示整个理论接触面积内所有的 MM 型接触 总的收缩电阻. I 0, I 1, I v  I 2 分别表示紧凑连接时通过同轴连接器交界面的总电流、通过 MIM 型接触支路电流、通过非接触区域的电流和通过 MM 型接触支路电流同时由于微小尖峰所形成的 导电连接结仅为金属接触表面面积的一小部分因此未接触区域等效电容 C tv 的容抗将远大于 MM 型接触阻抗 Rt−mm  MIM 型接触总阻抗 Zt−mim, 故电流 I v 的大小可以忽略不计那么在图 4 可将 C tv 所在的支路看作断路同时在紧凑连接条件下由于 MM 型接触形成的连接结较多所以 MM 型接触的总接触电阻 Rt−mm 远小于 MIM 型接触的总阻抗 Zt−mim, 那么 4 中电流 I 2 要远大于电流 I 1, 而电流 I 1 为通过绝缘膜层电阻 Rtf (非线性电阻会导致无源互调干扰的电流因此在低功耗、紧凑连接的情况下同轴连接器中由于交界面电接触原因所导致的无源互调干扰的量级几乎可以忽略不计.

松散电接触等效模型

 2 节阐示了金属电接触表面的微观结构特征并在此基础上建立了紧凑电接触的等效电路 释了在低功率、紧凑连接条件下电接触对无源互调干扰影响水平低的内在原因本节将以第 2 节的研究结论为依据并拓展到松散电接触情况下分别建立松散电接触的静态与动态模型为阐示松散电接触情况下两同轴连接器交界面的电特征参量变化提供分析依据.

3.1 松散电接触静态模型

在叙述静态模型之前需要提前声明的是为便于松散电接触程度的可控性本文所选用的同轴连接器没有固有的电连接故障即金属接触表面不存在轻微形变或受力不均匀等情况换言之所有 的松散电接触情况均通过控制连接器公头和母头的松紧连接程度实现同时本文不管是建立松散电接触的静态模型还是动态模型均是以紧凑连接为基础进行论述的因此在详细阐述静态模型之前先简要介绍紧凑电接触情况如图 5(a)(1) 所示红色倒三角形表示紧凑接触位置在实际应用中 以通过扭力扳手实现旋转扭力扳手当扭力扳手发出 “滴答” 声响时即表示此位置为紧凑接触位置对应的紧凑连接理论接触面积如图 5(a)(3) 所示即为两同轴连接器交界面的面积当将图 5(a)(1) 所示的紧凑接触位置逆时针旋转 θ 角时即出现图 5(a)(2) 所示的松散电接触情况根据逆时针旋转 θ角度的不同可实现不同程度的松散连接.

本节所定义的松散电接触静态模型是指同轴连接器处于某种特定程度的松散连接时 (例如: θ = 60所呈现的静止连接状态其关注的重点是特定程度松散连接所处的稳定状态而不是由紧凑连接到松散连接微观表面导电结 ( 3(b) 所示所发生的动态变化 5(a)(2)  (a)(4) 描述了松散连接程度为 θ 时所呈现的电接触情况可知当发生松散电接触时同轴连接器交界面将出现非接触区域且非接触面积随松散电接触旋转角 θ 的增大而增大.

由于同轴连接器的外导体是主要的接触力承受区域因此此处仅图示外导体的松散电接触情况如图 5(a)(4) 所示存在松散电接触时连接器的理论接触面积内会出现非均匀、不连续的接触与非接触区域当电流线由同轴连接器公头通过松散电接触交界面流入到同轴连接器母头时在连接器公头均匀分布的电流线在到达非接触区域时将发生偏折汇聚到接触区域再流入同轴连接器母头 ( 5(b) 所示). 电流路径在非接触区域的偏折、收缩效应会带来 3 方面不利因素首先电流线在接触区域的收缩、汇聚会使接触区域电流密度增大其次接触区域的电流密度增大会加大金属导体对电流的阻碍作用导致接触电阻增加最后电流线偏折现象会使电流路径变长在高频情况下会诱发额外的感抗 (电阻和感抗在后文中将统称为阻抗).

3.2 松散电接触动态模型

松散电接触的静态模型可以方便地解释处于某种特定程度松散电接触时同轴连接器交界面的电流密度、阻抗等电特征参量相对于紧凑连接所发生的整体变化但是该静态模型不能解释发生松散电接触时所发生变化的电特征参量相对于图 4 所描述的电路所处的具体位置不能明确同轴连接器交界面内的 MM 型与 MIM 型微观导电连接结在松散电接触过程中的动态变化情况为此本小节将建立一种松散电接触的动态模型用以描述在发生松散电接触的过程中连接器交界面导电结(MM  MIM 的微观动态变化情况.

在设计动态模型时仍然遵照 2.2 小节的设定将实际粗糙程度近似相同的两个接触面假定 为一个接触面绝对光滑另一个粗糙面的粗糙程度为原来的 2 参照图 6, 当两连接器表面相互接触形成紧凑连接时假定光滑接触面位于直线 (a) 处且位置不变粗糙接触面的平均高度位于直线 (c) 粗糙表面凸起尖峰的平均高度位于直线 (b) 直线 (b) 与直线 (a) 的距离为 d 0, 凸起尖峰与直线 (b) 的距离为 x. 在弹性形变条件下 (扭力扳手控制连接器实现的紧凑接触金属表面仅发生弹性形变), 当尖峰高度 x > d0 凸起尖峰与光滑表面发生 MM 型接触 x = d0 尖峰与光滑表面发  MIM 型接触 x < d0 尖峰与光滑表面不发生接触.

 6 示出了 5 种不同高度的凸起尖峰其中高度 x 1, x 3  x 4  MM 型接触但形成的连接结大小不一致 (尖峰嵌入光滑面的深度不一致); x 5  MIM 型接触即尖峰与光滑面刚好接触但二者之间有一层绝缘膜层; x 2 为未接触尖峰不形成导电结.

假设金属表面的凸起尖峰服从高斯分布那么金属表面此 5 种凸起尖峰的总数应分别相等当发生松散接触时即保持直线 (a) 位置不变直线 (b), (c) 和所有凸起尖峰整体轻微下移那么原来 MIM 型接触尖峰 x 5 将变为未接触尖峰; MM 型接触尖峰 x 1  x 4 的连接结将变小, x 3 将变成 MIM 型接触若进一步下移, x 3 将变为未接触尖峰, x 4 将变为 MIM 型接触依次类推直至两接触面完全 分离在整个分离过程中因为各种尖峰的总数分别相等所以 MIM 型连接结数量不发生改变减少 的仅为 MM 型连接结那么 4 所示的等效电路在松散接触情况下, MIM 接触支路不会发生任何 变化 (两同轴连接器完全分离瞬间除外), MM 型接触部分的阻抗值会随松散电接触程度不断增加即松散电接触导致增加的电阻与感抗应该位于 MM 型电接触支路中.

总之松散电接触的静态模型属于宏观模型解释了相对于紧凑连接松散电接触交界面的电特征参量发生了何种变化而松散电接触的动态模型属于微观模型它对于这种变化的电特征参数量在 等效电路中的位置进行了确定.

松散电接触电特性量分析

 3 节的建模分析可得出两个结论: (1) 松散电接触会使同轴连接器交界面的阻抗增大且增大的阻抗位于 MM 型电接触支路一侧; (2) 松散电接触会使交界面的电流线从非接触区域向接触区域汇 导致接触区域面的电流密度增大本节将在 CST 软件中建立同轴连接器的松散电接触仿真模型对上述结论进行仿真分析与验证.

4.1 松散电接触阻抗分析

如前所述松散电接触将产生不规则的非接触区域且该非接触区域的面积大小与松散电接触程 度正相关本小节将进一步探讨与验证非接触区域面积大小对同轴连接器交界面阻抗的影响机制根据图 2(a)  (b) 的描述本文在 CST 软件微波工作室中建立的 7/16 DIN 型同轴连接器仿真模型如  7 所示仿真模型的总长度为 20 mm, 其内导体的外径与外导体的内径分别为: 7 mm  16 mm; 松散电接触发生在距离右终端 10 mm 位置接触区域填充物为白铜导体材料其电导率为 5.96× 107 S/m, 非接触区域填充材料为空气其厚度为 0.3 mm.

种不同的松散电接触情况如图 7 所示情况 (1): 为紧凑连接即电接触面积为理论连接表面积情况 (2): 将电接触面积减少为理论连接表面积的一半情况 (3): 将电接触面积减少为理论连接表面 积的 1/3. 3 种情况下同轴连接器的阻抗仿真结果如图 8(a) 所示当紧凑连接时 7/16 同轴连接器交界面的阻抗仿真为 49.6 Ω (略小于理论计算值 50 Ω); 当接触区域面积分别减少为紧凑连接交界面 总面积的 1/2 同轴连接器交界面的阻抗值增加至 50.07 Ω; 当接触区域面积减少为紧凑连接交界面 面积的 1/3 同轴连接器交界面的阻抗值进一步增加至 51.48 Ω. 此仿真结果可进一步证实松散电接触交界面的阻抗值随松散接触程度增加而增加.

4.2 松散电接触面电流密度分析

关于松散电接触面电流密度的仿真分析仍采用如图 7 所示的仿真模型和对应的 3 种不同的松散电接触程度情形其仿真结果如图 8(b) 所示当同轴连接器紧凑连接时交界面接触区域的面电流密度与同轴连接器交界面以外区域的面电流密度一致 (如图 8(b) 的黑色双点虚线所示), 保持  3.15 A/m2 左右当接触区域面积减少为紧凑连接交界面的一半时交界面接触区域面电流密度增加至 3.29 A/m2 左右交界面以外区域面电流密度仍保持不变 (如图 8(b) 的红色点虚线所示); 当接触区域面积进一步减少为 1/3 交界面接触区域的面电流密度增加至 3.48 A/m2 左右交界面以外区域面电流密度仍保持不变 (如图 8(b) 的蓝色虚线所示). 从上述仿真分析结论可知发生松散电接触 同轴连接器交界面以外区域的面电流密度不受影响但随着松散电接触程度增加 (交界面非接触区域也随之增加), 电流会不断汇聚到交界面的接触区域中换言之松散电接触程度越高同轴连接器交界面接触区域的面电流密度越大.

4.3 松散电接触等效电路模型

通过上述对松散电接触的建模与仿真分析可以证实当两相互连接的金属存在松散电接触时 金属交界面会出现额外的阻抗且该额外的阻抗包含增加的电阻阻抗和电感感抗两部分增加的电阻是由于电流在交界面接触区域的汇聚作用导致电流线汇聚使电流密度增加那么金属对电流的阻碍作用也将增强进而导致额外的电阻阻抗增加的感抗是由于电流线在交界面非接触区域的偏折导致电流线发生偏折使电流路径变长高频情况下产生额外的感抗此外虽然同轴连接器交界面接触区域的面电流密度会随松散电接触程度增加而增大但因为交界面非接触区域没有电流通过所以在发生松散接触时交界面的总电流并未发生变换因此相对图 4 所示的紧凑电接触等效电路松散电接触的等效电路模型可用图 9 进行描述.

在同轴连接器紧凑接触的条件下, C tv 的容抗远大于 Zt−mim  Rt−mm, 因此电流 I tv 的值远小  I mim  I mm, 所以电路 可以当做开路当同轴连接器存在松散连接时非接触区域面积进一步 增大且电路  C tv 的容抗增加速度远大于电路 中阻抗 ∆Z 的增加速度 (不管紧凑或者松散连接金属交界面未接触区域占绝大多数). 因此在松散连接情况下电路 仍可视做开路在松散电接触情况下, MIM 型接触的绝缘膜电阻 Rtf 及其所在电路 没有发生任何变化但是 MM 型接触 支路 9 所示的电路 会增加额外的阻抗 ∆Z, 此阻抗 ∆Z 会使通过电路 的电流 I mim 增加进而导致 Rtf 消耗的功率增加易知: Rtf 是绝缘膜层电阻呈现非线性特性其消耗的功率增加必将会恶化电接触金属的无源互调干扰水平.

此外虽然松散电接触会使电流 I mim 增加但是电流 I mm 仍然占据总电流 I 0 的绝大部分这是因为金属表面电流必须依靠遂穿效应透过绝缘膜层才能形成遂穿电流 I mim, 遂穿效应是一种十分微弱的物理现象换言之松散电接触一方面使 MM 型接触支路的阻抗明显增加 (见阻抗仿真结果),  一方面总电流 I o  MM 型接触支路汇聚因此在松散电接触条件下, MM 型接触支路将产生明显的自热现象在高功率微波电路中将更为明显热现象会改变金属的温度敏感参量例如电阻率当接 触金属的电阻率发生变化时又会反向作用于接触面的自热现象如此双向作用的电热耦合效应使得金属的电阻率不再是一线性电阻它是恶化电接触金属无源互调水平的另一方面原因关于绝缘膜层电阻 Rtf (电子遂穿效应 MM 型接触支路电热耦合效应所导致无源互调干扰的定量描述关系 参阅本课题组前期已报道的文献 [17, 18].

本文目的在于概述松散电接触无源互调影响机理的内在各种作用因素阐示松散电接触导致无源 互调干扰的特点使得本领域的研究和工程人员能够在实践应用中快速定性地判定与定位微波电路或系统的无源互调干扰是否由电接触故障所导致并不是为了建立松散电接触定量的无源互调预测模型来预测不同松散电接触情况下的无源互调干扰值因此本文所采取的实验验证手段也是定性而非定量的方式.

实验测试

通过前述部分的分析可以知道松散电接触对连接金属交界面的电特征参数带来两方面影响: (1) 松散电接触会使连接金属交界面的阻抗值随松散接触程度增加而增加; (2) 松散电接触会使连接金属交界面接触区域的面电流密度随松散接触程度增加而增加因此本部分所设计实验也围绕此两方 面开展针对增加的阻抗对无源互调干扰水平的影响本文通过同种尺寸、不同制作材料的同轴连接器的方式进行验证针对增加的面电流密度对无源互调干扰水平的影响本文通过增大输入激励电流的方式进行验证.

5.1 测试装置

本文所搭建的实验测试装置如图 10 所示该验证平台由 3 部分组成反射式无源互调测试仪 ( 10 中编号 部分)、松散电接触被测试装置 ( 10 中编号 部分以及低反射无源互调终端负  ( 10 中编号 部分). 用无源互调测试仪产生双音激励信号到被测试装置并显示由被测试装置反射的无源互调测试结果整个回路的传输功率最终被低互调终端负载吸收由于采用的是反射式无源互调测试方法所以被测试装置以外的设备必须具有较低的无源互调反射值因此所选用的同轴 线缆、终端负载等都具有低反射无源互调特性.

本文采用的无源互调测试仪为美国通信器件公司 (Communication Components Inc., CCI)  PiMPro 1921 型产品且选用该无源互调测试仪的 PCS1900 频段其上行与下行带宽分别为 1930 1990 MHz  18501910 MHz, PCS 1900 的上行频带即为无源互调干扰可测试频段换言之被测器件 (device under test, DUT) 工作于 19301990 MHz 之间均可利用该型测试仪对被测器件的三阶与五阶无源互调值进行测试实践测试过程中发现当双载波输入频率 f1 = 1935 MHz, f2 = 1985 MHz 此时该无源互调测试仪产生的底噪最低因此本文的测试实验都选用此两个频率作为输入频率 么对应产生的三阶互调频率为 fPIM3 = 1885 MHz. 其中较高的三阶互调频率 2035 MHz 未落入其接收频段故测试时不作考虑.

5.2 测试结果分析

为实现同轴连接器不同程度的松散连接如图 10 所示在被测试装置 的左侧支架上设计一松 散角度标识器首先使用扭力扳手顺时针旋转同轴连接器的公头 (对应连接器的母头已被固定在铝合金支架上), 当扭力扳手发出 “滴答” 声之后表示连接器公头与母头已实现紧凑连接并将此处标识为紧凑接触或者松散连接角为 “0” 的位置然后利用扭力扳手逆时针旋转连接器公头的螺帽 (按松散角度标识器中蓝色箭头所示角度标识器的步进 (精度 10 ), 便可以实现不同角度的松散连接.

(1) 阻抗对无源互调干扰的影响测试. 3 种不同材料制作的 7/16 DIN 型同轴连接器 1 种是白 铜材料制作 (电导率: σ = 5.12 × 107 S/m, 此处电导率指室温 20的测量值);  2 种也为白铜材料制作但是在同轴连接器的交界面电镀了一层 10 µm  (电导率: σ = 3.76 × 107 S/m), 实际上相当于 铝制同轴连接器连接 3 种同样为白铜材料制作但是在同轴连接器的交界面电镀了一层 10 µm  (电导率: σ = 6.30 × 107 S/m), 实际上相当于银制同轴连接器连接测试时, 3  7/16 DIN 同轴连接器除接触面材料不同以外其余实验条件如同轴连接器尺寸、激励信号功率以及测试环境均保持一 利用图 10 所描述的无源互调测试平台, 3 种同尺寸、不同交界面材料 7/16 DIN 型同轴连接器的三阶无源互调值如图 11 所示 11 正方形、六边形和三角形符号分别表示铝制、铜制和银制同 轴连接器的三阶无源互调测量结果为便于分析结论对上述测量值进行数值拟合其拟合结果如图 11 中虚线所示.

从图 11 的测量结果可以得出两个结论首先三阶无源互调干扰值随松散电接触程度的增加而增 其次同等松散电接触条件下交界面为铝材质的同轴连接器的三阶互调值最高白铜材质的同轴 连接器次之银材质的同轴连接器的三阶无源互调值最低此三者的差异仅仅在于材料电导率的不同该实验结果表明电导率越高的材料其无源互调干扰值越小金属电导率与阻抗成反比也就是说电镀铝的同轴连接器交界面的阻抗最大、白铜材质的同轴连接器次之、电镀银的同轴连接器无源互调值最低此测试结果定性地证明了无源互调干扰值随同轴连接器交界的阻抗增加而增加与第 3 节的分析结论一致.

(2) 面电流密度对无源互调干扰的影响测试由于互调测试仪输出电压可保持恒定所以改变被测试同轴连接器的面电流密度可以通过输入不同激励功率实现参照图 12, 35 dBm, 30 dBm  25 dBm 3 种不同测试功率分别由无源互调测试仪施加到被测试电路中由于电压保持不变那么输入功率为 35 dBm 的面电流密度最大, 30 dBm 的面电流密度次之, 25 dBm 的最小其对应观测到的三阶无源互 调测试结果在图 12 中分别用三角形、圆形和正方形符号表示红色虚线表示相应测量结果的数学拟合值 (方便观察实验统计结果). 从图 12 所示的测量结果也可得出两个结论首先无源互调水平随输 入激励功率 (面电流密度增加而增加且输入激励功率越高产生的无源互调水平越高一致性也越 其次测试的三阶互调值并未像输入功率一样成 5 dBm 增长进一步体现无源互调干扰的非线性特点.

结束语

本文从金属电接触表面的微观特征结构入手对金属松散电接触的互调干扰现象进行理论建模、 软件仿真以及定性的实验测量分析结论指出松散电接触对无源互调干扰的影响机理存在两方面因素首先松散电接触现象使得通过非线性绝缘膜电阻的电流值增加进而恶化接触金属的无源互调水平其次松散电接触现象使金属交界面的阻抗增加和电流汇聚到接触区域进而在交界面产生明显的自热现象使接触金属的电阻率动态变化最终导致接触电阻呈现非线性特征进一步恶化接触金属的无源互调水平.

Posted on

PB2021.02 一种评估多载波倍增放电频谱的分析方法

下载PDF – 一种评估多载波倍增放电频谱的分析方法

AN ANALYTICAL METHOD TO EVALUATE THE SPECTRUM OF MULTICARRIER MULTIPACTOR DISCHARGE

 Abstract—Radio frequency (RF) noise can severely degrade the performance of electronic circuits and wireless systems. This article proposes an analytical method to evaluate the spectrum of RF noise caused by multicarrier multipactordischarge.First, a simplified model is developed to analyze the electric current characteristics of the resonant multicarrier multipactor discharge. Then, an analytical formula for the spectrum of the resonant multicarrier multipactor discharge is derived. Finally, the theoretical method is evaluated for dual-carrier operation inside a silver plated rectangular waveguide. Simulation results coincided well with theoretical findings show that the proposed method is encouraging.

Index Terms—Multicarrier, multipactor discharge, parallel plate model, rectangular waveguide, RF noise

关键词:多载波、倍增放电、平行板模型、矩形波导、射频噪声

I. INTRODUCTION

Multipactor is a nonlinear phenomenon which is caused by the interaction between the charged particles and the applied RF fields [1], [2]. Multipactors are generally classified into two types on the basis of the carriers of the applied RF fields, namely, single-carrier and multicarrier multipactor discharge. The main effort of this work is focused on the multicarrier mutipactor cases; the theoretical analysis and the resulting equations developed in this article are valid only for monoenergetic secondary emission.

As is well known, when there is an electric field between two small parallel plates, the initial electrons of the parallel plate region will be accelerated by the electric field and then impact against the surface of the plate. One or more electrons are released after impact. If some of the electrons synchronize with the electric field, such process as aforementioned is repeated until a steady state is reached (the growth of multipactor electrons ceases to continue) [3]. Multipactor discharge causes a number of negative influences such as the RF noise, passive intermodulation, impedance mismatch, and signal distortion, which can severely degrade the performance of microwave circuits [4]–[6].

In the past decades, various models and analytical methods were proposed to suppress or predict multicarrier multipactor breakdown in microwave devices [7]–[11]. For example, in [7], a new quasi-stationary (QS) prediction method for multipactor breakdown determination in multicarrier signals has been presented; the experimental results show that the QS prediction method offers better predictions than that the popular 20-gap-crossing rule. In [8], the performance of the most popular multipactor breakdown prediction method, i.e., the 20-gap-crossing rule, for multicarrier signals, has been checked by experiments. In [9], the Monte Carlo method has been proposed to find the thresholds and the global “worst case” waveforms of both single-event and long-term multipactors. However, in practical situations, it is almost impossible to completely suppress multipactor discharge for all cases. Therefore, it is necessary to understand the spectrum characteristics of multipactor discharge, as it is useful for designing the noise compression components and filters to eliminate the RF noise generated by multipactor discharge.

The spectrum characteristics of the single-carrier multipactor discharge have been well investigated by some works [12]–[15]. For example, Sorolla et al. [12] presented a model to evaluate the power spectrum of a single-carrier multipactor discharge. Semenov et al. [13] analyzed the amplitude spectrum of the multipacting electrons in rectangular waveguide with single carrier signal. Jimenez et al. [14] measured the power spectrum of the multipactor event excited in a single-carrier microwave circuit based on rectangular waveguides. However, a specific theory, which is used to analyze the spectrum characteristics of multicarrier multipactor discharge, attracts little attentions to the best of the authors’ knowledge [15].

In this article, a theoretical analysis method is presented to analyze the spectrum characteristics of the multicarrier multipactor discharge. It should be noted that the multipactor electrons are considered to resonate with the fundamental RF carrier. This article is organized as follows: Section II analyzes the frequency characteristics of the multicarrier RF field briefly; it will be used to find the period, harmonics, and subharmonics of the resonant multicarrier multipactor discharge in later Sections. In Section III, a simplified model of the multipactor electrons is stated first, and then a numerical expression for evaluating the spectrum of multicarrier multipactor discharge is derived. In Section IV, simulations are conducted to demonstrate the effectiveness of the proposed theories. Section V draws a conclusion of this article.

II. FREQUENCY OF MULTICARRIER RF FIELD

In this section, the frequency characteristics of multicarrier signals are proposed. A multicarrier signal u(t) (RF field) is composed of k carriers with frequencies ωi , angular phases ϕi , and amplitudes Ui , mathematically

where ωi = 2π fi , i are integers, and I = 1, 2…k. Furthermore, as detailed in [16], if fi are integers, the frequency f of the multicarrier signal u(t) is the greatest common divisor of the set carrier frequencies fi , mathematically

In practical microwave circuits, the precision of fi is usually limited to decimals; thus, the integer frequencies can be obtained by normalizing fi . For example, when f1 is equal to 2.33 GHz, the normalized integer frequency of f1 will be written as 2330 MHz.

Three cases (A, B, and C), when ϕi = 0, Ui = 1, and the carrier numbers are 2, 2, and 3, are shown in Table I to explain the analytical results in (2). As illustrate in Table I, the frequencies of cases A, B, and C are 0.5, 0.6, and 0.05 GHz, respectively. These demonstrated results will be used to analyze the period, harmonics, and subharmonics of the multicarrier multipactor discharge.

III. NUMERICAL ANALYSIS METHOD

In this section, the analytic model and mathematical expression are developed to analyze the spectrum characteristics of the resonant multicarrier multipactor discharge.

A. Analytical Model

As shown in Fig. 1, a parallel plate model is adopted to investigate the spectrum characteristics of the resonant multicarrier multipactor discharge. The length, height, and width for the parallel plate model are defined as d, h, and w, respectively. As shown in Fig. 1(a), the electrons resonate with the applied electric field and grow exponentially. The parallel plate model will be filled with the resonant electrons after a few nanoseconds, and the current of those resonant electrons is directly related to the multipactor noise [12]. Therefore, the cruces of eliminating the multipactor noise are the analysis on the spectrum characteristics of the resonant electron current.

B. Mathematical Expressions of the Spectrum Characteristic

As shown in Fig. 1(b), we assume that all resonant electrons are localized in a thin sheet L, and L is located at zL . Here, the bottom and top plates of parallel plate model are located at z = 0 and z = h, respectively. The distance between the thin sheet L and the bottom plate is |zL |. Because the resonant electrons are driven by the RF field u(t), the motion of the thin sheet L is repeated with the period of the RF field u(t). Furthermore, the direction of this thin sheet L orients only in the z-axis, when d L and w L are assumed; the theoretical model of this article is developed in Fig. 1(c). Therefore, the current density of the thin sheet L can be calculated as [13]

where v(t) is the instantaneous velocity of the thin sheet L, in the units of meter per second (m·s−1);


z is the motion direction of the thin sheet L (does not carry units); ρ is the volume charge density, measured in coulombs per cubic meter (C·m−3), and ρ can be further measured with putting a positive probe in the multipacting components [14]. Since the thin sheet L is directly derived by the RF field u(t), according to the Newton–Lorentz force law, the relationship between the instantaneous velocity v(t) and the RF field u(t) can be written as

where m and e are the electronic mass and the electronic charge, respectively. As Ui = U0 and ϕi = 0 are first assumed in (1), and then integrating (4), the instantaneous velocity v(t) can be expressed as

where t0 and v0 are the initial time and the initial velocity of the thin sheet L, respectively, and v(t0) = v0. T is the period of the RF field u(t). N is the multipactor discharge resonance order, and N = 1, 3, 5, 7, … odd.

Equation (5) consists of two parts, which are the oscillation velocity vosc(t) and the constant velocity vcon(t). As shown in (6), vosc(t) changes continuously with time t and thus contributes only to the basic carrier frequencies of the current density J [14]. vcon(t) represents an antisymmetric square-wave function with period NT, which changes in a step-like way after each impact against the surface of the parallel plate; the instantaneous jump of vcon(t) will lead to distortion of the carrier signals. Therefore, the harmonics and subharmonics of the current density J are completely determined by vcon(t).

As also shown in (6), vcon(t) is an antisymmetric step function with the period of NT. Therefore, vcon(t) can be expanded by Fourier series; the Fourier series is an expansion of a periodic function in terms of an infinite sum of harmonically related sinusoids [17]. Specially, the Fourier series of vcon(t) can be rewritten as

Furthermore, the Fourier coefficients a0, an, and bn of vcon(t) can be calculated as

Substituting (8) into (7), vcon_FS(t) can be rewritten as

where n is the orders of harmonics and subharmonics, and s belongs to positive integers. Since vcon_FS(t) is an expansion of vcon(t), vcon_FS(t) is equal to vcon(t), then v(t) = vosc(t) + vcon_FS(t).

When taking both vcon(t) and vosc(t) into considerations and ignoring the motion direction


z, the current density J can be rewritten as

Equation (10) shows an analytical expression to evaluate the spectrum of the current density of multicarrier multipactor discharge. The following conclusions can be drawn from (10): 1) in the first-order multipacting resonance N = 1, the odd harmonics ( f , 3 f , 5 f,…, and f = 1/T ) of the RF field u(t) are generated. For example, the harmonics are determined by the last term in (10) and expressed in
∞ n=2s−1 sin[2πn/T (t − t0)], where s belongs to positive integers, and n = 2s − 1; therefore, the harmonic components are 1/T , 3/T , 5/T,··· , n/T (i.e., f , 3 f , 5 f , ··· , nf, f = 1/T ). 2) in the higher order multipacting resonance N ≥ 3, the subharmonics are generated and can be described by 2πnf/N. It means that the frequencies of the subharmonics are directly related to the order of multipacting resonance N and the frequency f of the RF field u(t). 3) the magnitude of the multicarrier multipactor noise, including harmonics and subharmonics, decreases with the order n. For example, in (10), the amplitudes of harmonics and subharmonics are expressed in
∞ n=2s−1[v0 − (U0e)/(hmωi)
k i=1 sin(ωi t0)]4/(nπ ), and thus for a particular case of multicarrier multipactor discharge (i.e., the coefficients of v0, U0, k, h, and ωi are fixed), the amplitudes are only affected by n and decrease with it.

Two cases, which are used to further illustrate the frequency components calculated by (10), are shown in Fig. 2. The data employed to analyze the frequency components in the above two cases are set as follows: k = 2, t0 = 0, U0 = 30 V, v0 = 6.68 eV. Form the example, we see that the third, fifth, harmonics (3 f , 5 f ) and the seventh, eleventh, thirteenth subharmonics (7 f /3, 11 f /3, and 13 f /3) are very close to carrier frequencies and need to be addressed carefully.

IV. SIMULATIONS

In this section, a dual-carrier multipactor discharge, which occurs in a rectangular waveguide, is designed to demonstrate the proposed theories in Section III. The length and width of the rectangular waveguide are 10 and 8 mm, respectively. The height of the waveguide covers two different sizes, 0.6 and 2.4 mm, in order to provide the multipactor orders of 1 and 3. Silver-plated waveguide surfaces have been assumed; thus, the standard silver parameters in ECSS [18] are used as follows. δmax = 2.22, Emax = 165 eV, E1 = 30 eV, and taking v0 = 6.68 eV, SEY at low energies of 0.5.

The multipactor noises are investigated in the time domain and the frequency domain, respectively. A conformal time domain finite integration theorem (TDFIT) and particle in cell (PIC) hybrid method are used to simulate the dual-carrier multipactor discharge in the time domain [19]–[22]. Furthermore, two separate simulations, electromagnetic (EM) simulation and dual-carrier multipactor, are conducted in this work. Except for the difference of seed electrons, other simulation conditions such as RF fields, SEY, and material parameters are the same in both cases. In the dual-carrier multipactor simulation, the number of seed electrons is set as 600, which is employed to analyze the multipactor noise. In the EM simulation, the number of seed electrons is set as 0, which is employed as a controlled experiment to confirm that the RF noise only relates to the multipactor discharge.

The simulation results are shown in Figs. 3 and 4, where Fig. 3 illustrates the changes of the total electrons in the silverplated rectangular waveguide. It is easy to see that there is a significant increase in the number of the resonant electrons after 6 ns, which means the multipacting resonance occurs at t > 6 ns

Fig. 4 shows the results of the EM simulation (no multipactor) and dual-carrier multipactor discharge simulation in a silver-plated rectangular waveguide. The red dashed line represents the simulation result of the EM simulation, where the multipactor discharge is not presented due to the absence of seed electrons. The blue dashed dotted line represents the simulation result of the dual-carrier multipactor discharge. It is important to notice that a time-varying convection current is generated in the dual-carrier multipactor discharge simulation. This convection current is caused by the resonant electrons and always treated as multipactor noise because they can affect the integrity of the propagating signals [23], [24]. Comparing the results between Figs. 3 and 4, it is easy to see that the intensity of multipactor noise increases with the total number of the multipactor electrons.

In order to study the spectrum characteristics of the dualcarrier multipactor discharge, the simulation results in Fig. 4 are further analyzed in the frequency domain using a standard Fourier transform algorithm, and the corresponding results are shown in Fig. 5. The blue dashed dotted line and the red dashed line represent the power spectrum of the dual-carrier multipactor simulation and EM simulation, respectively. We can clearly see that the odd harmonics ( f , 3 f , 5 f , …) and subharmonics ( f /3, f , 5 f /3, …) emerge and decrease with the frequency ft, and ft is the frequencydomain variable of time t. As also shown in Fig. 5, a good agreement between the simulation results and the theoretical analysis results (i.e., the cyan open circles) is observed.

V. CONCLUSION

Although it is well known that the RF noise could be caused by the multicarrier multipactor, the frequency components of the multicarrier multipactor noise have not been sufficiently investigated. In this article, an analytical method of evaluating the spectrum characteristics of the muticarrier multipactor has been proposed. According to our investigation, the frequencies of the multipactor noise can be described by 2πnf/N, which are directly related to the multipactor discharge resonance order N and the frequency of the RF field. This conclusion is useful for designing the noise compression components or filters to eliminate the RF noise caused by multicarrier multipactor discharge.

ACKNOWLEDGMENT

The authors would like to thank prof. V. E. Semenov, Institute of Applied Physics, Nizhny Novgorod, Russia, for his helpful discussions in the theoretical analysis. The authors would also like to thank Dr. Yiming Zhang, Maritime Institute, Nanyang Technological University, Singapore, for his helps in the simulations and in the proofreading of this article.

Posted on

PB2020.11 一种提高重复性的继电器放电FICDM方法

下载PDF – 一种提高重复性的继电器放电FICDM方法

A RELAY DISCHARGED FICDM METHOD FOR IMPROVED REPEATABILITY

Abstract – A new design for CDM testing is proposed that retains the field charging DDT method while providing a consistent discharge inside of a reed switch. The method is shown to adhere to the current JS-002 standard and to perform at low voltages, but JS-002 failures could not be exactly replicated.

I. Introduction

A CDM event occurs when the pin of a charged device approaches an external metal object such that the potential difference exceeds the breakdown voltage of the air gap between them. The device generally becomes charged by either E-field charging, in which electric fields near the device cause the potential of the device to change without changing its net charge, or Tribo-charging, in which a static charge is generated when the device slides on another surface [1]. The field induced CDM method (FICDM) is one of the best methods to simulate a true CDM event. In this method, the device is placed on a dielectric sheet, under which a plate of varying voltage levels changes the potential of the device, thereby emulating the E-field charging method. However, current FICDM testers are plagued with repeatability issues due to the variable spark resistance of the air discharge making the practice difficult to standardize [1 ][2]. As CDM testing voltages decrease, the variability of the air discharge increases, causing concern over the ability to meaningfully classify devices at lower voltages [3]. This is becoming increasingly problematic as the necessity for classification at lower levels is becoming greater with advances in IC technology [1].

This work presents a CDM tester that incorporates a relay into the pogo pin structure and maintains adherence to the Joint CDM Standard ANSIIESDA/JEDEC JS-002 [2] for FICDM testing. The use of a mercury wetted reed switch in the pogo pin allows for a more consistent spark resistance during low voltage pulses when compared to discharges in air. The method also preserves the field induced charging method which closely replicates the real world CDM charging mechanism. This method may produce failures that cannot be exactly replicated by other contact first CDM testers [4]. The new CDM tester is evaluated in comparison to a standard FICDM system through discharge waveform comparisons on calibration modules and device failure analysis.

II. RP-CCDM Tester

A. Discharge Circuit

The RP-CCDM [5], or Relay Pogo-Contact First CDM is a design of the CDM discharge head that allows for the use of a repeatable relay discharge while largely preserving the design parameters of the JS-002 standard. Figure 1 shows a cross section of the RP-CCDM head.

As shown in Figures 1 and 2, the RP-CCDM uses the field charging method as well as a similar discharge path to the one specified in the JS-002 standard. To charge the device, the pogo pin of the RP-CCDM ground plane is lowered to contact the DDT pin, then the field plate is brought to the specified charge voltage. At discharge, the reed switch is closed and the current flows up the pogo pin, through a high bandwidth In resistor, and to ground. The voltage is measured across the In resistor from which the discharge current waveform is then calculated.

B. RP-CCDM Testing Procedure

The RP-CCDM charges the DDT after the pogo-pin has contacted the pin to be tested. This is to ensure failures due to non-measured currents passed through the capacitance between the lower pogo and the ground plane or through the capacitance inside the reed switch like the currents observed in [6][7], do not occur when the non-charged pogo tip touches the DDT. By contacting the pin ofthe DDT first, the potential of the lower portion of the pogo-pin is slowly increased concurrently with the potential of the device. Thus, no high frequency transient can pass through the capacitances as might occur if the neutral pogo tip touched a higher potential pin on the DDT. The single and double discharge methods specified in the JS-002 standard can still be used for pulsing in the RP-CCDM depending on when the discharge relay is closed. The process for the single discharge method, which was used for all tests in this work, is as follows:

Single Discharge Method

1) Test starts with reed switch open; field plate grounded

2) Descend and touch DUT

3) Switch field plate relay to HV at specified TC voltage x voltage ratio

4) Wait for DDT to charge

5) Close reed switch, measure the CDM current

6) Switch field plate to ground

7) Open reed switch

8) Rise and move to next pin

C. Reed Switch

The reed switch used in the pogo pin structure was chosen specifically for its small form factor. The switch was soldered directly to the center of the In current sensing resistor. A small 3mm pogo pin was soldered directly to the bottom lead of the reed switch to keep the length of the pogo structure as small as possible such that the inductance of the structure would not increase drastically. To analyze the impact the new structure would have on the capacitance and inductance of the RLC discharge circuit, a ZDUT measurement was taken of the system. This measurement setup can be seen in Figure 3. The outer rim of a SMA connector was soldered into a cutout on the center of a copper plated FR4 sheet, which is much larger than the CDM head ground plane, approximately 30 cm x 20 cm, and connected to Port 1 of the VNA. The CDM head to be analyzed was attached to Port 2. The pogo pin of the CDM head was placed on the center pin of the Port 1 SMA with the ground planes parallel and the S11 measurement was extracted from which the ZDUT was extracted. Figure 4 shows the ZDUT measurements of a standard FICDM and the RP-CCDM discharge heads. The measurement displays three clear regions where each of the components in the circuit dominate. The first positIve slope represents the frequency range where the inductance of the VNA ground loop dominates, the negative sloping region represents where the capacitance between the plates dominates, and the third region represents where the inductance of the pogo structure dominates [8].

The values of the capacitance between the plates and the inductance of the pogo structure were estimated by fitting the impedance curves of capacitance and inductance values to the ZDUT measurement. This was done by finding a linear best fit line between the peak and trough of the ZDUT and matching the capacitance or inductance value to the center frequency of the best fit line. The fitted lines provide rough estimates but allow for a general assessment of the differences between the discharge heads. This method yielded a significant increase in the inductance from approximately 4.5nH in the CDM pogo structure to approximately 8.9nH in the RP-CCDM pogo structure. Little difference was noted between the capacitance created by the RP-CCDM and standard FICDM head.

D. Charge Stored in the Pogo Tip

The tip of the RP-CCDM pogo structure is electrically isolated from the upper portion of the structure and the ground plane. As a result, there is a small charge that is stored in the tip when the DDT is charged. When the relay is closed the small amount of charge travels through the 10 current measurement resistor with the true stress current. To measure the extent to which this would be a factor in the discharge, the large verification module was charged at a field plate voltage of 500V with the pogo touching. After the module was fully charged, the head was raised up and the relay was closed. Figure 5 shows the discharge waveform measured from repeating this procedure ten times compared with the discharge from a JS-002 small verification module. The current measured is most likely negligible if the DDT is large. However, this could be of significance when testing a small DDT since the current produced from this extra charge is independent of DUT size. The possible effect on failure levels of small devices has not yet been evaluated.

The charge transferred during one discharge of the tip was compared to the charge transferred during one discharge of the small JS-002 module as a reference of the impact the additional charge could have, this is shown in Figure 6. Over 10 pulses the average charge transferred in a discharge of the pogo tip was 0.029 nC, whereas the charge transferred in a discharge of the small module was 2.593 nC on average. Thus, the charge stored in the tip represents approximately 1.14% of charge discharged from small verification module.

III. RP-CCDM vs FICDM Discharge Characteristics

A. Comparison of Standard Test Conditions

To test the discharge characteristics produced by the RP-CCDM head, it was tested using the small and large verification modules defined by the JS-002 standard [2]. The comparison data was collected using a standard FICDM head, also manufactured by ESDEMC Technology. The modules and pogo tips were cleaned with isopropyl alcohol before testing as well as the field plate dielectric surface. The humidity of the test environment was lowered to below 10% RH during testing of the standard FICDM head using a desiccant and compressed air system. As per the JS-002 standard a voltage factor was used to correlate the charge voltage with the desired discharge current. The voltage factor used for the RP-CCDM was 1.08 and the voltage factor for the standard FICDM was 1.02. The true 10 current measurement resistor values were 1.026 and 1.030 for the standard FICDM and RP-CCDM heads, respectively. All waveforms were measured using a 6GHz Bandwidth Oscilloscope.

A full test of both setups verified that they complied with the JS-002 standard measurements. The pulse width of the RP-CCDM was considerably longer than that of the standard FICDM head, especially with the larger module. This can be attributed to the increased inductance of the pogo pin. However, the RP-CCDM head easily fits into the pulse width specification in the JS-002 standard. Some distortion in the peak area is also seen across both modules. It is not clear yet whether this distortion has any impact on the failure levels of devices.

B. Linearity of Discharge Current

The main advantage of the RP-CCDM is the ability to produce a repeatable discharge inside of the reed switch portion of the pogo pin. Figures 9 and 10 were created by normalizing the current and voltage relationship of the TC125 test to 1, for both the standard FICDM and the RP-CCDM. A value of 1 represents a perfectly linear relationship. The highlighted region around the centerline represents where the highest and lowest pulses fell at each test level. To illustrate the repeatability benefits.

In addition to a more repeatable discharge, Figures 7 and 8 show the RP-CCDM is also able to produce a peak current that is more linear with respect to increasing voltage. The much lower pulse to pulse variation of the RP-CCDM would make it easier to standardize the failure levels of devices, which has been a large issue with standard FICDM testing [1].

C. Low Voltage Performance

Since the peak current variation is less in RP-CCDM configuration, this will provide better repeatability at low voltage levels. Table 4 and Figure 11 show the results of 100 discharges performed with a field plate charge voltage of 75V using the JS-002 small verification module for both the standard FICDM head and the RP-CCDM head.

As shown in Figure 12, the RP-CCDM can produce repeatable pulses within a +/- 5% window of the peak current even at voltages well below the lowest test condition used for classification.

Further, the RP-CCDM was tested at lower voltages to find where it could no longer produce repeatable pulses (at these voltages the standard FICDM was too unstable to trigger properly). The RP-CCDM tests were run in two ways: first, with the pogo pin sitting on the small verification module, charging and discharging without moving, and second, with the standard single discharge procedure. These results, tabulated and shown in Table 5 and Figure 12, showed that the pulse was less repeatable when the pogo pin re-contacted the disk every pulse. This difference is most likely due to small differences in contact resistance between pulses and highlights the impact contact resistance can have at very low voltages.

At 10V, over the course of 100 pulses there were many extraneous pulses for both stationary and moving tests, likely making the RP-CCDM pulse unclassifiable at this level. These results are tabulated and shown in Table 6 and Figure 13.

IV. Device Failure Analysis

Test ICs were used to investigate the failure correlation between the standard FICDM and the RP-CCDM test setups. Pre-charging voltage values are 500 V, 625 V and 750 V, while two devices are tested per each method using three discharges per polarity. The chip offers several power and 10 domains that are all stressed either in the FICDM test or RP-CCDM test, respectively.

The device failure analysis of the correlation study between FICDM and RP-CCDM is carried out via IDDQ testing. The failure is expected for pre-charging voltages higher than 500 V and located on the edge of the digital core. The IDDQ analysis measures the current consumption in the quiescent state on 200 vectors in the digital core.

The quiescent current into VDD for all vectors is below 100/lA, in case of an unstressed reference device. Slight deviations in this range are traced back to normal variations. A significant increase of the current compared to the reference device indicates a gate-oxide failure on the edge of the digital core.

The device stressed at 500V using FICDM method shows a current consumption below 100 /lA, indicating the device can withstand the stress. The device stressed at 625 V using FICDM method, shows an increased current consumption up to 180 /lA, which indicates a failure. The failure analysis of the devices stressed at 500V using RP-CCDM method, showed an increased current consumption between 210 /lA and 250 /lA, indicating failures. The device stressed using RP-CCDM method at 625 V, the measured current level is higher compared to the reference, and higher than the IDDQ values of the devices tested at 500 V using RP-CCDM method. Both failure analysis results for RP-CCDM method are interpreted as a device failure.

By comparing the IDDQ measurements for the failing devices, analyses show a very similar change for the same vectors. This is a strong indication that both test methods trigger the same failure mechanism. In order to get a deeper understanding of the failure mechanism and find out the pass level, a new device is tested with RP-CCDM at 400 V. The IDDQ analysis shows that the device can withstand this stress level. The IDDQ analysis is shown in Figure 14.

The discharge waveforms of a sensitive 10 pin are plotted for FICDM and RP-CCDM in Figure 15 and Figure 16, respectively. FICDM waveforms are recorded with 23 GHz bandwidth, RP-CCDM waveforms with 12 GHz bandwidth (different bandwidth is simply due to the RP-CCDM test being run at a later date with a different oscilloscope). The discharge waveforms are symmetric regarding the polarity, therefore, for simplification, only the positive waveforms are plotted. By comparing the peak currents of the discharges on the 10 pin, a dependency of the failure level on the peak current can be determined. The peak currents of each stress corresponding to the shown waveforms are listed in Table 7. The IDDQ analysis and the peak current values lead to the conclusion that the failure is triggered from exceeding the maximum peak current the device can withstand. According to the peak current values, the failure threshold is located between 4.1 A and 4.7 A.

The failures are reproducible for all tests with a statistic of four devices each, while all pins of the device are stressed.

Even if the waveforms for RP-CCDM are characterized by a longer pulse width and a slightly increased peak current, the total exchanged charge during the discharge event does not offer a significant difference between the different pins and testing methods. This is visualized with a box plot for twelve positive discharges on two devices and various pins in Figure 17. Further, the box plot shows that the RP-CCDM method produces less variation.

The EMMI scan for a failing FICDM and RP-CCDM device indicate that the spot of the failure is located in the core at the same place, meaning both methods trigger the same failure mechanism. Pictures of the failure signature are shown in Figure 18.

The failure level is further investigated by using Capacitively Coupled TLP (CC-TLP). This method allows correlating peak current levels or different pulse width settings to CDM stress parameters and can be applied to investigate CDM type failure modes [7, 9]. For the test device used in this study, the failure can be reproduced at about 5 A, using CC-TLP. FICDM and RP-CCDM failure levels are slightly different concerning the pre-charging voltage, but the CC-TLP test result supports that the failure mechanism is the excess of a certain peak current value.

The increased peak current of the RP-CCDM compared to the standard FICDM test could be adjusted with the test condition according to JS-002 in the future. RP-CCDM waveforms are very stable and the variation between several discharges is negligible, which is a benefit compared to FICDM.

Variations between standard FICDM discharges can be referred to the statistical influence of the spark that again varies with multiple parameters, such as the charging voltage or physical dimensions of package pins or balls. The spark limits the peak current and the oscillation, because of the resistive characteristic, which is considered as a series resistor and inductor in a circuit simulation [8]. Further, a slightly higher effective device capacitance could be assumed in the case of the RP-CCDM test, since the pogo pin is already touching the device before the discharge. This increase in capacitance is due to the fact that field plate and ground plate are closer together. The interaction between the device capacitance and tester capacitances are material for further investigations, including the altered resistance and inductance relationships.

V. Conclusion and Further Investigations

The RP-CCDM demonstrates that it can produce CDM pulses that closely match the pulses produced by a standard FICDM head within the testing framework of the JS-002 standard. However, device failure levels produced by the RP-CCDM head did not directly correlate to failure levels produced by the standard FICDM head. In the case study, the gap between failure levels at 500 V and 625 V can be referred to as a slightly higher peak current in the case of the RPCCDM waveforms. Further investigations into the current that could flow from the capacitance between the pogo pin and the ground plane or within the reed switch when the uncharged pogo tip contacts a charged DDT are needed. Full-wave simulations of the RPCCDM system are planned in order to better understand the effects any unmeasured currents may have on the test results.

VI. Acknowledgements

We would like to thank Dr. Kai Esmark from Infineon Technologies AG for providing the testing devices, for his support regarding the failure analysis and for sharing his wide knowledge of ESD, and in particular, of CDM.

Posted on

PB2020.09 射频信号对ESD保护二极管触发电压的影响

下载PDF – 射频信号对ESD保护二极管触发电压的影响

EFFECT OF RF SIGNALS ON TVS DIODE TRIGGER VOLTAGE FOR ESD PROTECTION

Abstract— Discrete transient voltage suppressor are used in addtion to the on-chIp ESD protection to protect the ICs from ESD damage. In applications involving snapback TVS devices, the trigger voltage is selected to be higher than the desired signals on the net. The presence of RF on the net affects the TVS behavior, even the RF levels are less than the snapback trigger voltage. Known affects are RF intermodulation and harmonic generation, which diminish HNR. This work describes the other effect on the TVS diodes, the observed reduction of the snapback trigger voltage, monotonically dependent on the amplitude of the RF signal. This translates into snapback triggering at low stress levels than specified in the datasheet or expected by the design engineer. TLP testing was performed using a 100 ns pulse with RF signal from 100 MHz to 2 GHz present at the diode terminals. The result show that the higher frequencies have a weaker impact on the reduction of snapback trigger voltage, and the phase of the RF signal impact the amount of reduction in the trigger voltage. It is also observed that certain TVS diodes recover from snapback even when the RFamplitude is higher than the holding voltage of the diode.

Keywords— Electrostatic discharge(ESD); radio frequency(RF) signals; snapback devices; transmission line pulse(TLP); TVS.

关键词:静电放电(ESD)、射频(RF)信号、滞回设备、传输线脉冲(TLP)、瞬态抑制二极管

I.INTRODUCTION

ICs are designed with internal protection elements to protect them for component level electrostatic discharge (ESD) stress events. In addition to the component level protection circuits, external transient voltage suppressor (TVS) devices are necessary at system-level to provide sufficient ESD robustness to a device [1]. Based on the signal interface type, appropriate TVS device are selected based on various TVS parameters and the signal interface design requirements. In [2], various TVS devices such as diodes, varistors, spark gaps, and polymers were analyzed using a custom designed board and the pros and cons were discussed for different use cases. The PIN limiter diodes which are typically used for power limiting applications, were analyzed in [3] to quantify their ESD robustness on RF paths and compared against the protection capability of a TVS diode. In [2]-[3], methods for characterization of protection devices were evaluated. ESD simulator, 100 ns TLP and VF-TLP are common measurement approaches to evaluate various devices for component-level ESD characterization. VNA measurement is used to evaluate impact of the protection device on signal integrity.

In [4], the harmonic generation of the diodes is characterized to understand their RF large signal behavior. RF was applied, but no TLP pulses have been applied at the same time. The authors of [5] propose a system that combines TLP and RF, but not simultaneously. It subjects the device under test (DUT) to TLP pulses, then followed by RF measurement (S-parameters, IIP3, noise figure, etc.) to characterize the DUT. The work presented in [6] characterizes the RF devices before and after ESD event. It was shown that the performance of RF circuits and devices can degrade at ESD stress levels below the failure levels proposed by the commercial human body model (HBM) testers. However, none of these works address the possibility of RF signals being present at the time of the ESD pulse.

In this paper, the ESD protection capability of the TVS diodes was experimentally characterized during the presence of RF signals at the diode. The goal is to quantify the change in the TVS behavior. Two types of TVS diodes were investigated: the non-snapback and the snapback type. The snapback type diodes are designed to have a holding voltage Vh lower than the trigger voltage Vt1. An example of snapback behavior in the I-V curve is illustrated in Fig. 1.

It is shown that non-snapback diodes are largely unaffected, but snapback device Vt1 is changed by the RF. At 100 MHz it is observed that Vt1 reduces proportionally to RF amplitude. The effect decreases with increasing RF frequency. A new measurement method was proposed which applies both the RF and the TLP pulse at the DUT simultaneously. The transient voltage and current, and the quasi-static I-V curve are analyzed. Based on the experimental results, an additional consideration is proposed for the TVS diode selection on RF interfaces.

II.MEASUREMENT SETUP

A. Traditional TLP characterization process

The industry-defined standard [7]-[8] 100 ns TLP setup consists of five main parts: a pulse generator, a voltage probe, a current probe, an oscilloscope, and a DUT – e.g., an ESD protection TVS diode. The simplified block diagram is shown in Fig. 2. The quasi-static I-V characteristic of the TVS diode under test is extracted from 70-90% window of the transient V(t) and I(t) waveforms captured by two channels of an oscilloscope.

The typical testing approach is to perform a sweep of the TLP charge voltage, and establish several characteristics: a) diode breakdown voltage Vbr, b) diode dynamic resistance Rdyn; in case of snapback TVS diodes: c) holding voltage Vh, d) snapback trigger voltage Vt1. In addition, device self-heating effect and physical failure levels can be observed.

The very fast TLP (VF-TLP) variation [9] of the characterization setup is often used for evaluating transient behavior of the protection devices (e.g. switching speed) for shorter pulses (1-10 ns) and shorter rise times (100-600 ps). This work, however, focuses on the 100 ns TLP test configuration.

B. RF+TLP characterization process

The 100 ns TLP setup allows for a wide variety of test results, but assumes no RF signal present across the diode terminals. A novel testing method is proposed; it allows to force RF signal on the DUT during characterization. ESD protection devices are evaluated in this scenario and the effect of RF on their performance is observed.

The RF+TLP test setup modifies the 100 ns TLP measurement system by ESDEMC [10]. The simplified block diagram is given in Fig. 2. The signal generator RF Source output is amplified to 15 W using AMP1. The 20 dB attenuator ATTEN1 reduces the stress seen by AMP1 output terminal, as TLP pulse is injected via a T-junction TEE1. As the pulse is injected, part of it propagates towards the amplifier and is subsequently dissipated and absorbed, while the other part is forced on the DUT.

Oscilloscope Channel 3 with a CT1 probe is used to determine the current that is forced into the DUT. Oscilloscope channel 4 with attenuator ATTEN2 measures the voltage at the DUT terminal. The original voltage pick-off tee and the CT1 probe on oscilloscope channels 1 and 2 respectively measure total injected current and voltage close to the injection point. Captured VDUT(t) and IDUT(t) are processed in the same way as the standard TLP in order to produce quasi-static I-V curves.

 

III.RESULTS

Four TVS devices are evaluated in this work, as mentioned in Table I.

A. Effect of RF on non-snapback TVS diode I-V characteristic

TVS1 is a non-snapback diode with Vbr = 9 V and Rdyn = 2.1 Ω. The effect of RF at 100 MHz, 1 GHz, and 2 GHz on this non-snapback diode is negligible. As an example, the effect of 100 MHz on the I-V curve is depicted in Fig. 3.

Figs. 4 and 5 illustrate the time-domain voltage and current waveforms during the presence of RF signals. To obtain the quasi-static I-V curve, the 70-90% window is applied to the time-domain waveforms. The voltage and current values during the 70 ns to 90 ns time are averaged to obtain the I-V curve plot. For a 100 MHz RF signal, the period is about 10 ns, which covers 2 cycles within the 20 ns long averaging window. Similarly, the period for 1 GHz RF signal is 1 ns and about 20 cycles are superimposed on the TLP signal in the averaging window. Lastly for a 2 GHz RF signal, the period is about 0.5 ns and about 40 cycles are overlapping in the I-V curve averaging window. Therefore, for each RF signal a full number of periods fall in the averaging window, thus the effect of added RF voltage is zero in average. In case of other frequencies, incomplete cycles within the 70-90% averaging window may affect the I-V curve values depending upon the phase of the RF signal and the TLP pulse. Furthermore, it is expected that lower frequencies may introduce more change in the I-V curve. In this case, the cycle is wider, resulting in stronger contribution to the average value calculation, as opposed to a narrower incomplete cycle (i.e. of a higher frequency signal).

B. Effect of RF on snapback TVS diode I-V characteristic

TVS2 is a deep snapback diode with Vt1 = 18.1 V and Vh = 2.6 V. The effect of RF with varied Vpp at 100 MHz on this snapback diode is depicted in Fig. 6. The effect on I-V curve is not strongly observed at 1 GHz and 2 GHz RF. Contrary to the non-snapback TVS diodes, the snapback diodes do exhibit reduction in their snapback trigger voltage Vt1 in the presence of RF signals. The reduction in the Vt1 also reduces with the frequency of the RF signal. At 3 Vp 100 MHz RF signal, a maximum reduction of 2.8 V is measured on the Vt1 of TVS2. TABLE II gives a summary of the effect for TVS2 snapback trigger voltage.

A deep snapback device showed reduction in the snapback trigger voltage, though a non-snapback TVS diode did not exhibit any change in its clamping behavior. To investigate this unique snapback TVS behavior, additional snapback TVS diodes are measured. TVS3 is a shallow snapback diode with Vt1 = 4.6 V and Vh = 2 V. The effect of RF with varied Vp at 100 MHz, 1 GHz, and 2 GHz on this snapback diode is depicted in Fig. 7. TABLE III gives a summary of the effect for TVS3 snapback trigger voltage.

 

The time-domain voltage and current waveforms of TVS3 during the presence of 100 MHz RF signal are plotted with and without RF. Fig. 8 illustrates the voltage and current waveforms prior to the snapback trigger. Fig. 9 illustrates the waveforms after snapback occurs. Contrary to the voltage time-domain waveforms in Figs. 4 and 5 for a non-snapback device, the voltage waveforms in a snapback device exhibit two key differences in their response. Consider the TLP waveform from 0 to 100 ns as the reference. For non-snapback TVS, the Vpp cycles are superimposed equally above and below the TLP pulse. However, for snapback type devices, the RF signal is not superimposed equally on the TLP pulse. Secondly, the Vpp swing on the non-snapback during the TLP pulse is not the same as the Vpp prior to the application of the TLP pulse. These two observations suggest why the two types of devices respond differently to the same RF signal.

The effect at lower frequencies is due to superposition of the voltage waveforms, so that the diode snapback triggers as , thus snapback occurs at lower TLP stress than nominally. At higher frequencies, the effect is weaker and does not follow this rule. A negative monotonic relationship between the RF frequency and reduction in Vt1 is observed.

When each measurement is repeated multiple times, another effect on Vt1 is observed: the voltage varies with the phase of the RF at the moment of the rising edge of the TLP pulse. The effect is illustrated in Fig. 10, and summarized for TVS4 for 100 MHz RF and swept RF amplitude. The figure shows positive monotonic relationship between reduction in Vt1 and RF amplitude. However, the trend does not follow the expected linear reduction of Vt1 with amplitude increase, caused by superposition of RF and the TLP pulse.

C. TVS device appears to not recover from snapback

TVS4 is a shallow snapback diode with Vt1 = 4 V and Vh = 1 V. The effect of RF with 1-7 Vpp at 100 MHz on the diode is depicted in Fig. 11. In this case, the TVS4 was only measured at 100 MHz, as maximal reduction in other snapback TVS diodes was observed at this frequency. The Vpp was increased to observe the trend in the reduction of the snapback trigger voltage. At 5 Vpp and higher, the TVS diode appears to not recover from snapback, but rather appears to stay in that regime for all consecutive pulses as long as RF is present on the net. Normally, this happens if Vdc > Vh and leads to diode damage. While a detailed understanding requires knowledge on the type and implementation of the snapback structure within the TVS a preliminary explanation is suggested. The RF voltage causes currents for two reasons:

Conduction current: if the peak amplitude of the RF current is large enough before diode turn-on, carriers are injected into the base regions (assuming SCR snapback TVS). Thus, even a weak excitation can trigger the snapback. Fig. 12 (b) compares transient voltages and describes the diode triggering and switching to low-impedance regime (i.e. snapback). It is evident from the curve corresponding to 5 Vpp RF, that triggering happens at a much lower voltage than in nominal conditions (i.e. “No RF”). Although not fully understood, it is reasonable to assume that the time needed to flush out charge carriers will influence the severity of this effect.

Displacement current: the RF voltage will cause a current in the parasitic capacitive paths within the TVS. This current may also inhibit the return from snapback.

TVS2 and TVS3 were tested for similar effect, but only reduction in Vt1 was observed. This suggests that specificity of die layout defines whether the appearance of snapback latch-up will occur.

IV.DISCUSSION

In the process of interface protection design, it is important to account for the reduction in the trigger voltage of snapback TVS diode due to the presence of the desired RF signals. The following difficulties can be anticipated and avoided if the diode is well characterized:

As observed in Fig. 12 (a) the current through the diode at RF Vpp = 5V is much higher than Vpp = 4 V prior to the arrival of the TLP pulse. Thus, the RF signal voltage will drop across the diode and reduce SNR at the receiver.

The increased current at higher RF Vpp = 5 V is only observed after the snapback device is triggered once by the transient event. The device remains in this state (conducting current) at large RF Vpp as long as the RF signal stays across the device.

Various non-linear effects of a TVS diode (e.g. voltage- dependent capacitance, etc.) cause intermodulation distortion (IMD) and harmonic generation [11], which degrade receiver performance. It is likely that a diode that behaves like TVS4 will cause stronger harmonics, leading to antenna desense. This behavior is an avenue for further investigation.

As RF Vpp increases, the snapback diode behaves effectively like a non-snapback TVS as observed in the I-V curve in Fig. 11. The figure shows an effective trigger voltage of Vbr < Vh. From the quasi-static behavior of the device, it appears that the TVS does not recover from snapback for the cases where Vpp = 5 V, 6 V, and 7 V. However, the time-domain waveforms in Fig. 12 depicts that the TVS goes into snapback at Vdiode << Vt1. It should be noted that the RF signal was constantly applied at the TVS device throughout the testing. This behavior was only observed for consecutive TLP pulses.

The root cause of the RF frequency dependence on device behavior is not well understood and needs further investigation. Device transient behavior simulation using SPICE-based models [12], [13] and TCAD are a possible tools to further analyze the reduction in trigger voltage due to presence of RF signals. Particularly for the lower frequency RF signal such as 100 MHz, the phase alignment of the RF pulse with the TLP pulse affects the reduction in the trigger voltage.

V.CONCLUSION

While selecting a snapback TVS diode for providing ESD protection on RF interfaces, the effect of RF signals on the trigger voltage of the diodes must be taken into consideration. Based on the proposed TLP + RF characterization setup, it was observed that in presence of RF signals, the TLP voltage that is needed to trigger snapback is reduced. The sample size of 4 diodes is limited and no generalizations can be made, however the trends show the following: 1) the effect of Vt1 reduction is positively dependent on RF amplitude, 2) reduction in Vt1 shows negative dependency on RF frequency, 3) non-snapback TVS diodes are largely unaffected by the RF signal.

For one of the investigated TVS diodes a sufficiently large RF signal makes the TVS appear to not recover from snapback. Due to the presence of RF, even weaker ESD stress can easily trigger the TVS diode into snapback. This effect is expected to take place when Vp > Vh, but the results suggest that this is not necessarily the case for all diodes. Each protection device should be evaluated separately. The system designer must account for a lowered trigger voltage for the snapback TVS diodes. A typical data sheet of a protection device does not provide information about the change of protection characteristics under various operating conditions. Including the effects observed in this work would lead to a more accurate understanding of the devices.

ACKNOWLEDGEMENT

This paper is based upon work supported partially by the National Science Foundation under Grant No. IIP-1916535.

 

Posted on

PB2019.08 基于VF-TLP表征的管脚限制二极管对ESD事件的鲁棒性

下载PDF – 基于VF-TLP表征的管脚限制二极管对ESD事件的鲁棒性

ROBUSTNESS OF PIN LIMITER DIODES TO AN ESD EVENT BASED ON VF-TLP CHARACTERIZATION

Abstract—PIN limiter diodes are primarily used for protection from excess RF power in RF circuits. These diodes are positioned onboard at the I/O lines of the RF circuits. If an ESD event occurs, the first line of protection is offered by the PIN limiter diode. The main questions addressed in this letter are: Can the PIN limiter diode protect the RF circuit against ESD? If yes, then what is their ESD robustness? How do they compare against the standard ESD protection TVS diodes? This knowledge can guide the reader to understand whether or not the PIN limiter diode can help prevent ESD damage. The robustness of the diodes is investigated experimentally using a very fast transmission line pulse tester with a 10 ns pulse width and about 300-400 ps rise time. These diodes are tested for their withstand current, turn-on time at 1 A current, turn-on voltage, voltage clamp at 1 A current, capacitance, signal bandwidth, and effective package inductance. These diode parameters are essential in quantifying the component-level response of a device under test. This letter shows that the PIN limiter diodes are not a suitable replacement for the TVS diodes as an intentional ESD protection device. In case an ESD event occurs, these diodes are robust to ESD current levels up to 2.5-9 A and offer limited protection. They may effectively complement the TVS protection by offering a fast turn-on time and protection up to a certain ESD level, after which the (slower) TVS takes over.

Index Terms—ESD, PIN limiter diodes, TVS, vector network analyzer (VNA), very fast transmission line pulse (VF-TLP).

关键词:静电放电、管脚限制二极管、瞬态抑制二极管、矢量网络分析仪(VNA)、超快传输线脉冲(VF-TLP)

I. INTRODUCTION

Electrostatic discharge (ESD) protection has become a necessary design element in high-speed RF and microwave circuits. However, introducing ESD protection elements on RF circuits may cause RF performance degradation [1]. To prevent RF performance degradation, devices with low capacitance are designed and implemented [2]. Protection elements can be designed and implemented internally to the high-speed RF ICs, or they can be implemented using onboard external devices such as TVS components [3]. Onboard protection methods involve the use of primary and secondary protection devices [4]. The ESD protection device is placed before the component/part to be protected from ESD as shown in Fig. 1. Here, the primary onboard protection is placed near the source of the ESD stress, and the secondary protection diode (on-chip) is inside the protected device.

Under normal operating conditions, the protection devices offer high impedance and behave as a capacitance to the signal path. When an ESD event occurs, the onboard primary protection device is intended to carry a majority of the ESD-induced current while the secondary protection device carries the remaining current. During the event, the protection device turns on and clamps to its clamping voltage. At this clamped state, the impedance of the device is low, and it diverts the ESD current from signal trace to the ground. As a result, the device is protected from the ESD event.

PIN diodes are used in various applications such as switches, attenuators and phase shifters [5]. PIN limiters differ from the PIN diodes based on the doping of gold atoms in the I layer (middle layer) of the diode. The gold doping in the I layer reduces the minority carrier lifetime. The time the diode takes to recover from the low impedance state back to high impedance state (after the application of RF input signal bursts) is proportional to the minority carrier lifetime. Therefore, a lower minority carrier lifetime represents a faster diode recovery time [6]. A protection device from Keysight [7] known as an integrated diode limiter, consists of two limiters which can provide both power limiting and ESD protection; i.e., utilizing limiters for an ESD protection application. The ESD robustness of PIN limiters has not been reported in the literature. The PIN limiters may also provide ESD protection, even though they are typically used as power limiters.

In this letter, the ESD protection robustness was experimentally investigated for the PIN limiter diodes with low capacitance and surface mount style packages. The diodes were tested using a VF-TLP tester with a 10 ns pulse width, and about 300-400 ps rise time. This setup has a faster rise time and a shorter pulse width than the 100 ns standard TLP waveform. The IEC 61000-4-2 specification [8] stipulates that an I/O trace of interest on the PCB or an RF-circuit will not be subjected to a direct ESD discharge. The IEC pulse is expected to occur at a different location in the system. A regular TLP pulse has a rise time of approximately 10 ns. More important parameter than the pulse width is the rise time to assess the voltage overshoot during an ESD generator discharge. A VFTLP pulse [9] has a much faster rise time, typically 0.6 ns. A TLP waveform with a 100 ns pulse width and a rise time of 0.6 ns could be used, but it would not be possible to distinguish between two potential failure mechanisms, over-voltage due to the fast rise time and thermal damage due to the long pulse width. Thus, a narrow fast rising pulse is considered a better match than 100 ns TLP or IEC pulse.

II. ESD PROTECTION COMPONENTS

A. PIN Limiter Diodes

Fig. 2 (a) depicts a typical power limiter application using the PIN limiter diodes. These diodes are soldered from trace to ground, which is similar to the implementation to the ESD protection implementation shown in Fig. 1. PIN limiter diodes from different vendors such as Macom/Aeroflex, Skyworks, and Microsemi were investigated.

B. TVS Diodes

TVS diodes are specifically designed to protect devices against damage from ESD events. PIN diodes can be a part of the internal structure of a low capacitance TVS diode [10] as shown in Fig. 2 (b). In this TVS configuration, PIN 1 and 2 would typically be designed such that ESD robustness for both polarities is approximately equal.

The TVS diodes are one of the most effective ESD protection devices amongst the other TVS components [3] such as varistors, spark gaps, and non-linear polymers. The focus of this letter is to investigate the robustness of various PIN limiter diodes to an ESD event and compare it against a TVS diode [11].

III. VF-TLP TEST SETUP

The device under test (DUT) I-V curve was measured using an ESDEMC VF-TLP tester [12] illustrated in Fig. 3. The I-V curve was used to extract diode parameters described in detail in Section IV. To evaluate the performance of the diodes, a grounded coplanar waveguide (GCPW) prototyping PCB board was used. The VF-TLP measurement setup details are as follows:

Non-overlapping time domain reflectometry method was used to measure the DUT current and direct voltage measurement method to measure the DUT voltage [13].

A VF-TLP pulse width of approximately 10 ns was applied to the DUT, to evaluate the first few nanoseconds response.

An oscilloscope with 20 GSa/s sampling rate and 6 GHz bandwidth was used. The rise time of the VF-TLP pulse measured at the oscilloscope was approximately in the range of 300 to 400 ps.

To determine the quasi-static I-V curve, the measurement window was set at 70% to 90% of the pulse width. The measurement window setting was applied to the flat region of the waveform. A measurement window is the range of time within the pulse width where the voltage or current of the pulse is measured to calculate the DUT voltage or current in response to the applied VF-TLP pulse [14].

• VF-TLP pulse polarity: An ESD event can have both positive and negative polarities. Emphasis was placed on the reversed bias diode clamping and its ESD current carrying capacity. In reversed bias orientation, the turn-on voltage is higher than the forward biased (p-n junction) turnon voltages approximately in the range of 0.7 to 0.8 V. It should be noted that the forward biased polarity is much more robust than the reverse biased polarity. This argument is based on the lower power dissipation of the forward biased orientation against the reverse biased orientation. For example, for the same TLP clamp current, the forward bias diode clamp voltage is lower than the reversed bias voltage and their turn-on voltages are different. In addition, this is strictly true if the current for the forward and reverse polarity are flowing through the same device (internal to the package).

The source measure unit (SMU) measured the leakage current of the DUT when 1 V was applied to the reverse polarity of the DUT after each TLP pulse.

IV. DIODE PARAMETERS AND MEASUREMENT RESULTS

The measurement results are shown for one PIN limiter diode Microsemi 4701-206 [15].

A. Capacitance

The capacitance is determined to be 0.25 pF at 50 MHz. The frequency point is determined from the 20 dB per decade region of the Z21 vs. frequency plot shown in Fig. 4 (a).

B. Frequency Bandwidth and Effective Package Inductance

A 3 dB cutoff point is chosen as the usable frequency bandwidth of the diode. The dotted line in Fig. 4 (b) represents the diode’s frequency bandwidth (approximately 14 GHz). The dotted two-sided arrow is a visual representation of the 3 dB insertion loss of the diode in excess of the trace insertion loss. The diode is modeled as a series RLC circuit in the passive (non-conducting) state. The LC resonance of the diode (approximately 19 GHz) is used to calculate the effective package inductance (0.27 nH) given by the formula:

C. Turn-On Time, I-V Curve, and Leakage Current

1) Turn-On Time: Using the VF-TLP tester setup, the diode time-domain voltage and current waveforms were measured for each VF-TLP source excitation voltage. In general, the DUT voltage waveforms can have inductive overshoot, snap back behavior or the non-inductive overshoot [16] for the very first nanoseconds and then followed by a relatively flat voltageclamping region. The non-inductive overshoot is caused due to the conductivity modulation in the silicon [17]. The qualitative illustration for the overshoot and the non-overshoot response of a diode is shown in Fig. 5. The diode clamp current is determined from the diode current waveform by applying the measurement window setting. The measurement window of 70% to 90% was applied to the diode voltage waveform, and the time-averaged voltage value was determined (VDUT). Vtrack refers to the voltage amplitude 30% above in case of an overshoot response and 30% below in case of non-overshoot response in the measured diode voltage waveform. The time associated with Vtrack voltage is called t2. The difference between the two times t2 and t1 is calculated as the turnon time. It should be noted that if a different % criteria is used for Vtrack, the turn-on time values for different diodes would change, but the overall trend and conclusions will not be affected. The diode current of 1 A is chosen as a comparison unit for the turn-on time parameter. A current of 1 A through the diode is typically used by TVS vendors for determining the diode clamp voltage [11]. In Fig. 6 (a) the vertical dotted lines represent the two time values that result in the turn-on time of 2.16 ns for the TVS diode and 0.21 ns for the PIN limiter diode. It should be noted that for the PIN limiter diode at 1 A current, the waveform was considered as a non-overshoot waveform to determine the turn-on time parameter. It was observed that the TVS diode [11] voltage waveform has an overshoot response in the initial nanoseconds followed by the flat clamping region.

2) I-V Curve Plotted for a Measurement Window of 70% to 90%: The VF-TLP pulses are applied to the DUT. Each pulse generates a diode current and diode voltage waveform. The measurement window is applied to the diode voltage and current waveforms to determine the average voltage (VDUT) and current (IDUT) values. The VF-TLP currents are in the range of 10 mA to 20 A. In this measurement range, the instrument applies about 50 pulses to the DUT. This generates an array of 50 voltage and current values, which are represented in the form of an I-V curve plot as shown in Fig. 6 (b).

3) Withstand Current: The VF-TLP pulse voltage at which the leakage current increases 10x to 100x from the initial leakage current value of the diode is chosen as a selection voltage. A VF-TLP pulse voltage lower than the selection voltage is chosen as the maximum withstand voltage. At this particular VF-TLP pulse voltage (maximum withstand voltage) the current at DUT (diode) is determined as the maximum withstand current the diode can handle. It should be noted that the SMU measures the diode leakage current after the application of every VF-TLP pulse. A withstand current (IDUT) of 3.7 A (using a 10 ns VF-TLP pulse width) is determined for the diode shown in Fig. 6 (b).

4) Turn-On Voltage: The voltage at which the diode current is in the range of 1-10 mA is determined as the diode turn-on voltage. Using this definition, a value of 21.8 V is obtained from the I-V curve plot shown in Fig. 6 (b). Here, the turn-on voltage refers to the quasi-static voltage measured at 70% to 90% of the pulse width, and not to the maximum dynamic voltage.

5) Voltage Clamp at 1 A: The voltage corresponding to a diode current of 1 A is used to determine this parameter. It is a parameter provided in TVS datasheet [11] to quantify the clamping behavior of the diode. The voltage clamp for different current levels can be determined from the complete diode I-V curve shown in Fig. 6 (b). Using this parameter definition at 1 A diode current, a voltage of 28.8 V is obtained from the I-V curve plot. This voltage value indicates that for a 1 A current through the diode, this diode will clamp at a voltage of 28.8 V.

V. DISCUSSION AND CONCLUSION

Table I summarizes the different diodes tested, and their performance based on critical parameters. The diode capacitance, inductance, and frequency bandwidth parameters are essential to quantify the influence of the diode on signal integrity while the diode is in a passive state (during a non-ESD event). ESD withstand currents of about 2.5 A to 9 A have been observed, as well as turn-on voltages in the range of 20 V to 50 V. A frequency bandwidth of 6 GHz to 16 GHz is achievable, based on the different diodes tested in this letter. Diodes having smaller packages may offer larger bandwidths, due to the lower capacitance and inductance. The PIN limiter diode data was compared with an industry standard ESD TVS protection diode. Although most of the PIN limiter diodes that are shown in Table I may have faster performance for the turn-on time parameter than the ESD TVS diode, the ESD TVS diode has better performance in all other ESD diode parameters. Still, a PIN limiter diode may be part of a circuit design to protect against accidentally coupled high RF power. In this scenario, the PIN limiter diode will offer a moderate level of ESD protection.

Considering a system level ESD requirement for PIN limiter diodes, based on the faster turn-on time parameter, they can complement the TVS diode for the initial low-current ESD event. However, the TVS diode needs to turn on before the current through the PIN limiter crosses the withstand current. It should be noted that the turn-on voltage of the PIN limiter diodes are higher than that of the TVS which may limit the applicability of the PIN limiter and TVS combination. Thus, a system efficient ESD design (SEED) [4] will be needed further to evaluate a specific PIN Limiter and TVS diode combination for ESD protection application on a desired I/O trace.

Posted on

PB2019.08 可调速自控ESD模拟器空气放电稳定性分析及实验验证

下载PDF – 可调速自控ESD模拟器空气放电稳定性分析及实验验证

摘要:空气放电是最常见的静电放电(ESD)形式,但由于其重复性低,相关标准中没有给出其放电电流的标准 波形,这直接影响了对空气放电抗扰度实验的研究。ESD模拟器放电电极的接近速度是影响空气放电的电流波形 重复性的主要原因之一。利用研制的带垂直导轨可调速ESD模拟器空气式静电放电实验平台,能够对ESD模拟器放电电极驱近速度进行精确控制。利用该平台与人手持ESD模拟器分别对电流靶和受试设备(EUT)进行了空气放电实验研究,结果表明,研制的实验平台由于实现了放电电极接近速度的精确控制,能够使放电电流波形达到 较好的一致性。该装置将为电子设备静电放电抗扰度实验中空气放电实验的重复性提供一种解决方案。 

关键词:静电放电;空气放电;放电电流;抗扰度测试;接近速度

引言

静电放电(electrostatic dischargeESD)是常见的近场电磁危害源,会通过传导或辐射干扰对电子产品产生干扰或损坏。为了研究电子设备或系统抗静电干扰的能力,人们制定了相关标准,规定了静电放电抗扰度实验测试平台、测试方法等。在静电放电抗扰度实验中,是利用 ESD 模拟器模拟实际中的静电放电。而 ESD 模拟器的放电形式有接触式放电和空气放电。在现行的静电放电测试标准 IEC 61000-4-2 标准中,直接放电以接触式放电为首选方 法,在不能使用接触式放电的情况下,才考虑用空气放电进行测试。标准中的间接放电是对金属耦合板进行放电,首选的实验方式也是接触式放电。此外,虽然标准中保留了空气放电实验方式,但它只给出了针对接触式放电的校准电流波形,没有针对空气放电的校准电流波形。

由于空气放电的放电机理复杂,放电电流波形受到很多因素的影响。除了温度、湿度、压强等环境因素外,放电电极接近待测设备的速度、放电电 压大小等都会对空气放电的电流波形造成影响[1-5] 因此,空气放电的可重复性较差。

针对电子设备的系统级 ESD 测试[6-9]及仿真研 [10-13],基本是选择可重复性较好的接触式放电。 但在实际生产和生活中,空气放电是最常见的放电形式,也是对电子设备造成干扰和损害的主要原因。 在缺乏空气放电的标准放电电流波形的情况下,通过研究和改善测试平台和测试方法[14-17],获得重复 性、稳定性较好的放电电流波形十分重要。

研究人员先期研制了一种通过步进电机控制 ESD 模拟器放电电极使其以固定速度对电流靶进行空气放电的装置,但该装置是控制放电电极水平移动接近电流靶的[18-19]。为了解决某些电子产品需 要水平放置以方便对其进行静电放电实验(例如本  2.3 节所介绍的液晶显示触摸屏)的问题,本文进 一步研制了带有垂直导轨的可调速自控 ESD 模拟器空气放电实验平台,该平台不仅可使 ESD 模拟器的放电电极从竖直方向接近电流靶或受试设备 (equipment under testEUT)放电,而且由于采用了 更好的步进电机控制设计和整体结构的力学稳定性 设计,能精确控制 ESD 模拟器驱近速度,使得空气 放电的稳定性大大提高。通过将该装置与人手持 ESD 模拟器进行放电的结果进行比较,可调速自控 ESD 模拟器空气放电实验平台的放电电流波形的 一致性有显著提高。

带垂直导轨的自控 ESD 模拟器空气放电 实验平台

1.1 装置介绍

可调速自控 ESD 模拟器空气放电实验平台由 空气放电控制监测仪、装配有 ESD 模拟器夹具(托架)的垂直导轨和计算机组成,完整的实验平台装置见图 1ESD 模拟器的夹具固定在垂直铝制导轨上,该夹具采用 3D 打印机设计并打印,具有可调节孔径,以适合不同型号的 ESD 模拟器,垂直导轨可使 ESD 模拟器放电尖端垂直向下移动放电。导轨依托于三角形支架,并与 1 块水平放置的大铝板固定, 从而实现了整个系统的力学结构稳定性。测试时, 可将水平铝板接地,形成接地金属平面,EUT(本文为液晶显示触摸屏)放置于大铝板上,可方便移动和更改放电位置。空气放电实验平台的装置结构框图 见图 2。电极接近速度控制系统的简图见图 3,置于 托架上的 ESD 模拟器可在顶部限位开关和底部限位开关之间的导轨上垂直移动。

该测试平台使用了优质步进电机,通过控制总 线与计算机相连,并通过控制硬件和软件编程控制 步进电机的移动。通过步进电机的转速,准确计算出 ESD 模拟器在垂直导轨上的移动速度,其速度控制范围为 5~500 mm/s,误差绝对值< 5%。该实验平台兼具对环境温度、湿度、压强的监测。

1.2 实验方法

电子设备的起电源(人体等)通常是在接近电子设备的过程中发生静电放电,因此放电模式为空气放电。在研究静电放电对电子设备的影响时,必须对放电因素进行考虑,并在实验过程中对各因素加 以监测和控制。通过利用自控式平台,能够实现对影响因素之一的电极接近速度的精准控制。

如图 4 所示,ESD 模拟器被放置在 ESD 模拟器托架中,设置好移动速度,按下启动按钮后,ESD 模拟器托架会带着 ESD 模拟器以设定的速度沿导轨垂直向下运动,直到到达底部限位开关为止。在 这个过程中,放电电极以一定的放电间隙对 EUT 进行空气放电。但在实际应用中,ESD 模拟器可以 不用到达底部限位开关,其向下运动的终止位置可根据 EUT 的高度不同进行调整。通过几次上下移动,确定移动的起始位置和移动的距离,然后在控制软件中设置移动的距离,这样能够防止 ESD 模拟器放电电极在接近速度较大的情况下撞击到 EUT 造成硬件损伤。

EUT 进行空气放电之前,需要对实验平台稳定性进行初步验证。实验平台初步稳定性的验证中, 将首先使用电流靶作为受测对象,连接到电流靶的示波器用来记录流过电流靶的放电电流。实验平台稳定性得到初步验证后,将利用该平台对 EUT 进行空气放电,使用电流钳及示波器记录放电电流波形, 通过对比同一接近速度下的电流波形的稳定性进一 步验证该平台的稳定性。在测试中,示波器均通过 衰减器连接到电流靶或电流钳,以避免瞬时大信号对示波器的损坏,同时,示波器被置入法拉第笼内, 以减小辐射场的干扰。

稳定性验证

2.1 ESD 模拟器放电电流校验

在验证实验平台空气放电的稳定性前,需对 ESD 模拟器的放电电流进行校验。由于 IEC 标准中只规定了接触式放电的标准放电电流波形,因此需选择接触式放电模式,对通过 20 dB 衰减器连接到示波器的电流靶进行放电。放电电压±4 kV ±8 kV 下获得的放电电流分别见图 5 和图 6

根据 IEC 61000-4-2 规定的标准放电电流波形和相关参数,该 ESD 模拟器产生的放电电流波形符合标准规定的放电电流。

2.2 对电流靶进行放电

通过比较人手持 ESD 模拟器和平台控制 ESD 模拟器对电流靶进行空气放电时的放电电流波形一 致性,对该测试平台的稳定性进行初步验证。放电电压为±8 kV,接近速度选取为慢速(平台电极接近 速度为 0.1 m/s)和中速(平台电极接近速度为 0.3 m/s)。每种情况测量 3~5 次。图 7 为测量结果,图中的 Ipeak为电流峰值,下标数字分别对应实验序号。 ±8 kV 放电电压下,空气放电电流波形主要有 2 种,一是放电电流第 1 个峰的上升沿陡峭,接近于 接触放电电流,此时 Ipeak表示放电电流第 1 个峰的 峰值;二是第 1 个峰的上升时间明显增大,第 1  峰不明显,此时 Ipeak表示放电电流第 2 个峰的峰值, 如图 7(c)所示。

由图 7 可以看出,在放电电压极性为正时,种控制方式下的波形稳定性、一致性没有明显的差 异。但相较于人手持 ESD 模拟器放电,平台控制下的放电电流的第 1 个波峰的峰值大于第 2 个波峰, 场分量较大。在放电电压极性为负的情况下,人手  ESD 模拟器放电时的放电电流波形一致性则明显差于平台控制下的放电电流波形。在温度、湿度以及放电电压和极性相同的情况下,为了尽可能得到稳定性好的空气放电电流波形,电极接近速度的控制成为关键。人控制的慢速和中速具有很大的随 机性,且无法保证是匀速接近电流靶。相比较之下, 能够精确控制放电电极以某一速度匀速接近电流靶 的实验平台测得的波形一致性比较好。此外,放电点位置的准确性也是影响波形稳定性的因素之一。

平台控制和人手持 ESD 模拟器进行空气放电时的电流峰值见表 1

由表 1 可知,在同一放电电压和接近速度下, 自控式平台测得的电流峰值均大于人控制 ESD  拟器放电时的电流峰值,其放电电流的能量较大。 随着接近速度的增加,平台测得的电流峰值和手动 测得的电流峰值有所增大。但由于接近速度偏小, 增加的幅度不是很大,在 1~4 A 左右,这与文献[2] 中的结论是符合的。

 8 为平台控制电极快速(0.5 m/s)接近电流靶放电时的放电电流,放电电压选取为±4 kV  ±8 kV。考虑到电流靶放电点接触面积较小,人手  ESD 模拟器快速接近电流靶时,可能会造成放电点偏离正确位置,影响放电电流。这里没有进行人手持 ESD 模拟器进行放电的测试。

由图 8 可知,在±4 kV 的放电电压下,电流波形重合度高,稳定性较好。比较而言±8 kV 放电电压下的电流波形稳定性较差。放电电压对电弧结构 的影响可能是造成电流稳定性差异的原因。

综合比较可得,在温度、湿度、电压和极性可控的条件下,对电极接近速度进行控制能够得到稳 定性较好的空气放电电流。该实验平台进行空气放电时放电电流的一致性得到初步验证。

2.3 对触摸屏进行放电

在实际的静电放电抗扰度测试中,受测对象不是电流靶,而是某一电子设备。注入电子设备的放电电流的一致性将直接影响到测试结果的可信度。

目前带有液晶显示(liquid crystal displayLCD) 触摸屏的智能手机、平板是人们日常生活中使用率最高的便携式电子设备。人体是最常见的静电携带 源,触摸屏使用的频繁性以及由大量感应元件组成 的触摸屏本身高灵敏度的特性都大大增加了触摸屏受到静电放电干扰的可能性。因此,本文将选取智 能手机、平板等作为待测对象,基于该实验平台进行空气放电测试,研究注入到触摸屏上的放电电流 波形的稳定性。这里需要注意的是,由于屏幕四周有绝缘结构,火花难以穿透屏幕,因此对 LCD  摸屏的空气放电一般是无火花放电[20-21]

随机选取 3 种市面上常见品牌的智能手机、平板作为待测设备,使其良好接地,屏幕均用酒精擦拭干净,避免屏幕上积累的静电荷或灰尘、油脂对测试结果的影响。进行+8 kV 空气放电,放电位置为触摸屏中心,放电速度分别为慢速(0.1 m/s)、中速(0.3 m/s) 和快速(0.5 m/s)。使用通过 20 dB 衰减器连接到示波 器通道的F65电流钳测量对屏幕进行空气放电时的放电电流。其中,示波器被放置在法拉第笼内以防止辐 射电磁场的干扰。测试结构框图见图 9

 10 为利用 3 种接近速度分别对 3 个触摸屏进行放电时的放电电流波形测量结果。

从图 10 中可以看出,放电电流波形和接近速度有明显的相关性。由于空气放电本身的可重复性问题以及不同电子产品的特性不同,会使得同一接近速度下的放电电流有所不同。但显然,同一接近 速度下不同触摸屏的放电电流波形一致性较高,峰值、上升时间等参数相似度较好,这再次论证了前面对实验平台稳定性的验证。在研究空气放电对电子设备的影响时,对放电电极的移动速度进行准确的控制能够很好地提高测试的可重复性和测试结果的稳定性。

结论

1)由于空气放电的机理复杂性,其放电电流 很难达到类似于接触式放电下放电电流的波形稳定性。通过对电极接近速度的准确控制,和人手持 ESD 模拟器相比,可调速自控空气静电放电实验平 台得到的空气放电电流波形达到了更好的一致性。

2)对触摸屏的空气放电测试表明,同一接近 速度下的放电电流波形具有较好的相似度。这表明, 在电极速度可控的情况下,电子设备的空气放电测试具有一定的可重复性。

3)研制的可调速自控空气静电放电实验平台总体上能够获取重复性较高的放电电流。这为完善电子产品的空气放电抗扰度测试、提升测试结果的可信度提供了参考。但目前,该实验平台控制的电 极移动速度最高只能达到 0.5 m/s,无法进行高接近 速度(> 0.8 m/s)下的空气放电实验,这是后续研究可以进行完善的地方。

Posted on

PB2019.06 显示屏表面空气式静电放电实验特性

下载PDF – 显示屏表面空气式静电放电实验特性

摘要:显示屏是人机交互的重要部件,当人体静电放电发生在显示屏表面时,有可能导致软硬故障。 为了研究显示屏空气式静电放电实验特性,通过一个自制的装置对显示屏空气式静电放电电流和通过显示屏的位移电流进行了实验测量。研究发现:放电电流峰值随接近速度的增加而增加,上升时间随接近速度的增加 而减小。在±10~±12kV电压范围,受电弧长度的影响,上升时间增大,电流峰值变小。随着测量点与放电 点之间距离的增大,位移电流波形峰值减小、上升时间增大,正极性放电峰值更大且扩散范围更广,而负极性放 电上升时间增大更加明显。由位移电流波形及其分布可以计算出电荷密度。电荷密度随距离放电位置距离的增大而减小。与正极性相比,尽管负极性放电电流峰值较低,但电荷密度较高,说明负极性放电具有造成更高等级损伤风险的危害。

关键词:静电放电;空气放电;电流峰值;上升时间;位移电流;电荷密度

显示屏是现代电子设备的重要组成部分,是实现人机交互的重要平台,随着新技术的发展,显示屏的应用和使用越来越广泛,其需求不断增长[1]。触摸屏是通过手指触摸的方式进行操作,很容易遇到人体静电放电 (ESD)问题。静电放电可以导致显示屏和触摸屏软硬故障,目前针对显示屏静电放电的研究有:使用F65电流钳测量不同类型显示屏瞬态放电电流及其比较[2];利用铜片对显示屏各个位置的静电放电电流的测量[3];显示 屏静电放电电流全波模型的建立[4];移动显示驱动芯片的系统级 ESD 软硬故障研究[5];液晶显示器(LCD)面 板驱动芯片的失效研究[6];移动设备液晶显示器的静电放电扰乱模型的建立[7];静电放电软故障诊断方法研究[8];使用2.5DEM 工具对 ESD软故障进行调试和近场仿真[9]。

静电放电火花不能穿透玻璃,然而,静电放电和显示屏及其驱动电路之间存在着各种各样的通道和耦合路 径[3]。如果显示屏没有良好的隔热结构,放电火花就可能会到达连接显示屏和主板的柔性电缆。如果表面玻璃与显示层之间边缘封装结构受到电击穿,火花就可以进入显示屏。放电火花还可以到达其他金属结构,如系统框架[4]。特别是当火花到达柔性电缆或玻璃层之间的封装电路中时,会损坏或扰乱显示屏。然而,许多显示屏设计都由绝缘结构包围显示屏,这样静电放电就不能直接放电到接地结构。对于设计完好的显示屏,ESD 测试人员如果在空气放电模式下使用 ESD发生器进行放电,将不会观察到任何火花。未观察到火花往往会误以为没有电流。ESD发生器放电尖端靠近显示屏表面时将引起表面充电,在<1ns上升时间内达到10A  流[2]。显示屏上的非火花放电电流会在显示屏表面玻璃上向各个方向扩散,并以位移电流的形式通过玻璃层, 进入显示屏内部。放电火花还可以在显示屏边缘的表面传播,到达柔性电缆或穿透用来连接显示屏不同结构单元的胶水,到达显示器的内部结构,并破坏这些结构。在设计完好的系统中,绝缘屏障良好,火花不能在显示器的边缘传播。因此,最可能扰乱或损坏显示屏的路径是通过玻璃的位移电流。

无火花放电在显示屏表面玻璃产生的电荷可以用 Lichtenberg粉尘图法可视化。正极性电压放电的粉尘 图为分支扩展结构;负极性电压放电的粉尘图为密度更大的圆形结构,而不是分支结构[10]。虽然粉尘图能够 在放电后使电荷分布可视化,但却不能分析电极周围的瞬态位移电流。为了测量电荷密度随时间的变化与分布,Mueller设计了一种利用分段地平面来测量局部电流的装置[11]。基于相同的概念,同时为了使测量速度更快,本文工作中使用了类似的分段地平面来捕捉位移电流和电荷分布。

本文主要对显示屏进行空气式静电放电实验,通过一个自制装置捕获通过显示屏表面玻璃的位移电流,研究了放电电流、位移电流和电荷密度及其分布的主要特性,同时研究了不同放电电压、不同放电极性以及不同 ESD发生器接近速度对放电电流和位移电流的影响。

 实验装置与测试方案设计

实验分为两部分,显示屏空气式静电放电放电电流与表面玻璃位移电流的测量,测量系统如图1所示。测量系统主要包括:ESD模拟器、ESD空气式静电放电速度控制器、采样率5GS/s和带宽2GHz示波器、20dB 衰减器、法拉第笼。空气式静电放电速度控制器由空气放电控制监测仪和导轨组成。ESD 模拟器由特制的夹具固定于导轨上,由空气放电控制监测仪控制上下移动,速度0.05~0.5m/s可调。F-65电流钳置于 ESD 模拟器夹具之中,位于 ESD模拟器放电尖端处。测量系统整体放置在标准静电放电抗扰度测试平台上。法拉第 笼、示波器接地。图1(a)为放电电流测量系统,放电电流使用 F-65电流钳测量,显示屏放置于铝板上。图1 (b)为位移电流测量系统,为了测量通过表面玻璃的位移电流,设计了一块PCB板。

在玻璃表面上扩散的放电电流会导致玻璃表面电位的快速变化。这种快速的电位变化将使位移电流通过电容扩散到显示器的内部结构,例如触摸层或显示层。无火花的电流路径如图 2所示。此外,火花还可能发生在 ESD 发生器的放电尖端与显示器的内部结构之间,例如柔性电缆。在设计完好的系统中,显示屏边缘的绝缘屏障可以防止出现这种类型的火花。

ESD模拟器对显示屏放电后,显示屏表面的静电放电电流从放电点沿着显示屏表面玻璃向四周扩散,形成位移电 流通过玻璃到达下一层。为了测量通过表面玻璃的位移电流,设计了一块PCB板,如图3所示。PCB板的正面有8个排成一排的贴片天线,尺寸为3 mm ×3mm。贴片天线的周围为参考地平面。每个贴片天线通过中间位置一个尺寸很小的过孔与 PCB板背 面的微带线相连。测量位移电流时,将显示屏表面玻璃层紧紧按压在 PCB板的正面,使玻璃与 PCB板之间的缝隙尽量小。ESD模拟器对表面玻璃放电后,放电电流在玻璃表面向四周扩散,形成位移电流通过玻璃,PCB 板上的贴片天线感应到位移电流。然后经过导线、衰减器连接到示波器通道,实现位移电流的采集。

实验之前先校准 ESD模拟器、电流钳和衰减器,实验时湿度为40%,温度为25 。ESD模拟器选择人体金属模型和空气式放电模式,在不同放电电压水平、极性(±4kV,±6kV,±8kV,±10kV ±12kV)以及 不同放电电极接近速度(慢速:0.1m/s,中速:0.3m/s,快速:0.5m/s)条件下分别进行放电实验,记录放电电流波形和位移电流的特征值并通过示波器保存波形数据。

 实验结果与讨论

2.1 放电电流

有大量学者研究了空气式静电放电特性,实验中通常是采用 ESD 模拟器对电流靶进行放电,其实验结果 表明,不同放电电压、不同极性、不同接近速度条件下,放电电流峰值和上升时间差距较大[12-13]。本文中,研究  ESD模拟器对显示屏放电时,不同放电电压、不同放电极性以及不同 ESD模拟器接近速度对放电结果的影响。

图4给出的是ESD模拟器对显示屏表面的放电电流,ESD模拟器接近速度为0.3m/s。在放电电压为± kV 时,电流钳没有捕捉到电流波形,所以图中放电电压从±4kV 开始。显然,放电电流峰值并不总是随放电电压的增大而增大,上升时间也不总是在小范围内波动。为了研究不同放电电压、不同放电极性和不同接近速 度对放电电流波形的影响,在不同条件下进行放电实验。图5、图6分别为不同放电电压、不同放电极性和不 同接近速度的放电电流波形的电流峰值与上升时间。放电电流峰值随接近速度的增加而增加,上升时间随接近速度的增加而减小。在±4~±8kV,电流峰值随放电电压的增加而增加,而在±10~±12kV,电流峰值随放电电压的增加而减小;上升时间随放电电压的增加而增大。

上述现象出现原因是电弧长度的影响。放电电压较低时,电弧长度很短,而在放电电压较高时电弧长度较长[12]。放电电压相同时,放电能量相同,当电弧长度较长时,上升时间增加,能量在更长时间释放,则电流峰值 减小;同时电晕也会造成部分能量的损耗,导致放电电流波形总能量减少,电流峰值随之减小。接近速度会影响统计时间延迟,进而会影响到电弧长度[13],放电电压一定时,接近速度越快,在相同时间延迟内电极移动距 离越长,电弧长度越短,放电能量释放越集中,则放电电流峰值越大,上升时间越小。

2.2 位移电流

在设计完好的显示系统中,绝缘屏障良好,火花不能在显示器的边缘传播。因此,最可能扰乱或损坏显示屏的路径是通过玻璃的位移电流。为了捕捉电流分布,设计了一个 PCB板,其中包含8个3mm×3mm 的贴 片天线,贴片天线的周围为参考地平面,如图3所示。PCB板安装在玻璃背面。

将一块显示屏表层玻璃紧紧贴在位移电流测量 PCB板上,调整 ESD模拟器放电尖端位置,使放电尖端与 PCB板上的贴片天线#1的中心位置重合。静电放电发生器的电压设置为±8kV,该值是 ESD测试典型的电 压等级。相对湿度控制在40%左右,位于 ESD 测试要求的范围(30%~60%)内。为获得位移电流风险评估的上限,ESD模拟器的接近速度设为快速0.5m/s,如图7所示。由2.1小节可知,在±10-±12kV 放电电压, 电流峰值随放电电压的增大而减小,于是列出了放电电压±12kV、接近速度0.5m/s的位移电流,如图8。

为了更直观的了解位移电流,从各贴片捕获的位移电流波形中提取出电流峰值与上升时间,如表1、表2 所示。由表1可知,位移电流波形的峰值随测量点与放电点之间距离的增大而减小,相对于负极性放电,正极性位移电流峰值更大且扩散范围更广。由表2可知,位移电流上升时间随测量点与放电点之间距离的增大而 增大,负极性位移电流上升时间增大更加明显。由于玻璃是绝缘体,ESD 模拟器对显示屏表面玻璃放电后,电荷在玻璃表面向四周扩散,并残留在玻璃表面,同时随着扩散距离的增加,扩散面积增大,电荷分散,因此位移电流峰值随距离的增加而减小。

2.3 电荷密度

 2.2小节中的结果显示,相同放电电压的正、负极性放电电流峰值差异较大,负极性放电时电流峰值和放电能量虽然较小,但其影响的范围也更小。因此,仅考虑放电电流是不妥当的。通过2.2小节中测量的位移电流,对静电放电的电荷密度进行分析计算。电荷密度与位移电流有关,是一种测量 局部干扰触点或显示层风险的方法,比放电电流更能说明静 电放电对显示屏局部区域的损伤风险。由文献[10]可知,粉尘图的形状以放电点为中心呈对称形状,因此根据粉尘图的 对称特性,可以认为与放电点距离相等的圆环上,放电电荷密 度近似相等。因此可以通过贴片上测量的位移电流和贴片相 关的环面区域来计算电荷密度,测量图形如图9所示。放电 点位于贴片天线#1中心的正上方,对应图9中编号为1的方格。以贴片天线的边长为环径,将放电区域划分 为1,2,3,4,5五个区域,1区域为贴片天线#1所处的圆,圆半径为1.5mm。2~5区域为环径为3mm(大小 为贴片天线尺寸)的同心圆环,环心为放电点。

各区域电荷密度计算公式为

式中:I 为各区域对应的贴片天线所测位移电流;r 为圆环外半径。例如,对于区域2,r  4.5mm。由式(1) 结合图7、图8所示的位移电流测量波形,分别计算放电电压为±8kV,±12kV 时显示屏各区域的放电电荷 密度,结果见表3。

电荷密度的这种计算方法是基于位移电流的测量结果而得,比放电电流更能说明静电放电对显示屏局部 区域的损伤风险。从表3的结果中可以看出,静电放电的电荷密度随着距放电点位置的增大而减小。在相同 放电条件下,虽然正极性的放电电流峰值比负极性大(+8kV,+12kV 时分别为5.57A,5.40A,-8kV,-12 kV 时分别为-2.43A,-1.35A),但是负极性放电在放电点处的电荷密度比正极性的结果高。从结果中还可以看出,负极性放电的电荷密度消减速度比正极性要快得多。这说明负极性放电具有造成更高等级损伤风险的危害。虽然±12kV 时放电电流峰值小于±8kV,但是电流密度更大,因此危害更大。

  

 本文通过自主设计的装置测量了对显示屏表面玻璃空气式静电放电的放电电流和通过显示屏的位移电 流,研究了不同放电电压、不同放电极性和不同 ESD模拟器接近速度对放电结果的影响;基于位移电流的测量结果,计算出显示屏上非火花放电的电荷密度。

放电电流峰值随接近速度的增加而增加,上升时间随接近速度的增加而减小。在±10~±12kV 放电电压,电流峰值随放电电压的增加而减小;上升时间随放电电压的增加而增大。其原因是电弧长度的影响。放电 电压较低时,电弧长度很短,而在放电电压较高时,电弧长度较长。接近速度会影响电弧长度,接近速度越快, 电弧长度越短。当电弧长度较长时,上升时间增加,电流峰值减小。

位移电流与放电电流有关,位移电流波形的峰值随测量点与放电点之间距离的增大而减小;位移电流波形 的上升时间随测量点与放电点之间距离的增大而增大。正极性位移电流峰值更大且扩散范围更广,而负极性位移电流上升沿时间增大更加明显。

电荷密度比放电电流更能说明静电放电对显示屏局部区域的损伤风险。电荷密度随着距放电点位置的增 大而减小。与正极性放电相比,尽管负极性放电电流峰值较低,但电荷密度较高,说明负极性放电具有造成更 高等级损伤风险的危害。同样的,虽然±12kV 时放电电流峰值小于±8kV,但是电流密度更大,因此危害更大。

Posted on

PB2019.04 对地空气式静电放电特性试验

下载PDF – 对地空气式静电放电特性试验

摘要:为充分了解电子设备空气式静电放电(ESD)放电电流的特点,利用研制的带垂直导轨 可调速ESD模拟器空气式ESD试验平台,在不同放电电压、不同放电极性和模拟器不同接近 速度,针对对地空气式ESD进行了试验研究。 试验结果表明,在一定电压范围内,放电电流峰 值随放电电压的升高减小,同时上升时间随放电电压的升高而增大;模拟器接近速度越大, 放电电流峰值越大,上升时间越小;在某些放电电压下出现多次波形。对地空气式ESD可与电子设备空气式ESD试验结果相互印证,为电子设备ESD损伤机制提供试验和理论基础。 

关键词:空气式静电放电;放电电流波形;放电电流峰值;上升时间;多次波形

静电放电 ESD 具有高电位和大瞬时电流[1] ,会对电子设备造成损伤或干扰。 近年来,随着微电子 技术和器件工艺的迅猛发展,各种微电子器件的集 成度大幅度提高,使得电子设备的电磁抗扰度降低 且抗过压能力下降。 ESD 严重威胁着现代信息化电 子设备和武器系统,尤其对电子设备的潜在性失效威胁更为严重且难以预测[2-3]

ESD 可分为 2 类,电流注入放电和空气击穿放 [1]。由于空气式 ESD 涉及到外部火花通道的形成过 程,温度、湿度、放电电压的大小与极性、模拟器放电电极接近被测物体的速度等因素都会引起放  过程的显著变化,因此该方式的放电重复性极差[4]。然而,空气式 ESD 是实际工程技术和生活环境中出 现概率最大的放电现象,也是对电子器件和设备造 成损伤或干扰的最主要方式之一,成为电子工业迫 切需要解决的一个重要问题[3-5] 因此对空气式 ESD 的试验研究及其规律的研究刻不容缓。

在前期,原青云、贺其元等 人进行了关 于电流 靶的空气式 ESD 试验[46] ,但在实际 ESD 抗扰度测试中,受测对象不是电流靶而是某一电子设备。 为了能够使电流靶的空气式 ESD 与具体电子设备的 空气式 ESD 的试验结果相互印证, 在相同环境、相同位置进行了不同放电电压、不同极性、不同放电电极接近速度等条件下对地空气式 ESD 试验研究。

1试验装置与试验方法

对地 ESD 放电电流波形测量系统如图 1 所示。 该系统包括 ESD 模拟器、1 GHz 带宽 F65 电流钳、 ESD 空气式静电放电速度控制器、采样率 5 GS/s  带宽 2 GHz 的示波器、20 dB 衰减器、法拉第笼。

空气式 ESD 速度控制器由空气放电控制监测 仪、导轨、铝板 3 部分组成。 ESD 模拟器由特制的夹具固定于导轨上,由空气放电控制监测仪控制上下 移动,速度 0.050.5 m/s 可调。 F65 电流钳置于 ESD 模拟器夹具之中,位于 ESD 模拟器放电尖端处。 铝板放置在标准 ESD 抗扰度测试平台上。 法拉第笼、 示波器、铝板接地。

试验前,校准 ESD 模拟器和电流钳,环境湿度 30%,温度 22 °C。试验时,ESD 模拟器选择人体金属模型和空气式放电模式, 在不同放电电压水平、放 电极性(±2±4±6±8±10±12 kV)以及 不同放电 电极接近速度(0.10.30.5 m/s)的条件下,分别进行对地空气式 ESD 试验,记录放电电流波形的特征值并保存波形数据,每种试验条件重复 6 次。

试验结果与分析

2.1 放电电压对空气式 ESD 的影响

试验研究发现,放电电极接近速度一定时,随着放电电压的增加,无论正极性还是负极性的放电,放 电电流波形均发生极大变化,如图 2 所示。  2 为模拟器接近速度为 0.3 m/s 时,不同放电电压 U 的放电电流波形主波形。  2a 和图 2c 为放电的完整主波形,图 2b 和图 2d 为对应主波形第一峰的放大图。

IEC 61000-4-2 标准[7]中,给出的 ESD 模拟器接 触式放电电流波形的典型参数,放电电流峰值 Ip 与放电电压成正比,上升时间 tr  0.71 ns 文献[46] 中对电流靶的空气式 ESD 实际测量值表明:放电电 流峰值大小在±20 kV 以下大体上随放电电压线性增加,与接触式放电情况一致;上升时间随放电电压的增加而增加,但呈非线性,即电流波形的前沿 逐渐变得平坦,这在±12 kV 及以下放电电压时是极其明显的。

对地空气式 ESD 试验中,±2±4±6 kV 放电电压的放电电流峰值及变化趋势与 IEC 61000-4-2 标准一致,上升时间趋近相同;但在±8±10±12 kV 放电电流峰值随放电电压的增大而减小,上升时间 随放电电压的增大而增大,如图 3 和图 4 所示。  3,图 4 分别为模拟器接近速度为 0.3 m/s 时,不同电压放电的放电电流峰值和上升时间。

为在同一试验条件下记录不同放电电压、 极性的峰值放电电流与上升时间,接近速度0.3 m/s 试验条件改变时,放电电流峰值与上升时间同时发生变化:随着放电电压的升高,放电电流峰值变小 的同时,上升时间增加。 在图中表现为放电电流波形第一峰高度变小的同时变平缓, -8 kV 时尤为明显,第二峰高度随放电电压增加不断增大;而在 81012 kV 时第一峰高度不断变小,±12 kV 时第二峰的高度甚至超过了第一峰。

上升时间随放电电压的增加而增加,但呈非线性, 即放电电流波形前沿逐渐变得平坦的现象,出 现的原因是放电电压较低时电弧长度很短,而在放电电压较高时电弧长度较长[2] 放电电压相同时,放电能量相同,当电弧长度较长时,上升时间会增加, 能量在更长时间释放,则电流峰值减小。 同时,电晕也会造成部分能量的损耗,导致放电电流波形总能量减少,电流峰值随之减小。

2.2 接近速度对空气式 ESD 的影响

不同接近速度、不同放电电压时放电电流峰值和上升时间分别如图 6,图 7 所示。 由于放电电流峰值的异变从±8 kV 开始,而放电电压小于±8 kV 时,上升时间趋近相同,因此图中仅列出±8±10±12 kV 时的放电电流峰值和上升时间。

由图 6 可见,模拟器接近速度越大,放电 电流峰值越大,与放电电压极性无关。 由图 7 可见,模拟器接近速度越大,上升时间越小,与放电电压极性无关;随着放电电压的增大,上升时间随之变大, 在放电电压极性为正时尤为明显。 在接近速度为 0.5 m/s 时,上升时间变化极其微小。

接近速度会影响到统计时间延迟,进而影响到电弧长度[4] 放电电压一定时,接近速度越快,在相 同时间延迟内电极移动距离越长, 电弧长度越短, 放电能量释放越集中,则放电电流峰值越大,上升时间越快。

2.3 放电电流波形出现多次波形

试验发现,放电电流波形 出现了二次、三次甚至四次波形。 放电电压为-12 kV,接近速度为 0.3 m/s 时完整的放电电流波形如图 8 所示。

不同放电电压、不同极性单次放电下产生的完整放电电流波形如图 9 所示。 为方便制图与观察, 将多次波形的时间轴前移,使各次波形处于同一起 点。 模拟器接近速度为 0.3 m/s,各图中横轴坐标的 范围相同,纵轴分度不同,大小不能直接比较。 由图 9 可知,多次波形分别在+2 kV -8 kV 初次显现。

记录多次波形参数以及 单次放电的 多次波形之间时间间隔 ti 由于多次波形个数即使在试验条件完全相同时也不尽然相同,所以仅列出主波形与 二次波形之间的时间间隔,如图 10 所示。

 10 为不同放电电压、 不同极性单次放电产生的完整放电电流波形的主波形与二次波形的时 间间隔。 由图可见,随着模拟器接近速度的增加,主波形与二次波形之间的时间间隔减小。  10 结果 表明,时间间隔随放电电压的增大而增大,随接近速度的增大而增大。

对多次波形产生原因的分析是电容的充放电作用,即 ESD 抗扰度试验平台的结构,如图 11 所示。铝板、水平参考平面、接地参考平面通过接地线构成 3 层电容结构,ESD 模拟器放电尖端携带静电荷,铝板、 水平参考平面感应出静电荷,放电尖端击穿空气放电后,由于水平参考平面与大地之间连接 2 470 kΩ 电阻,电荷倾泄较慢,反之对 ESD 模拟器放电尖端产生感应,使放电尖端再次携带静电荷。与此同时,ESD 模拟器在自动速度控制器的控制下继续向下移动, 直到放电尖端携带的静电荷再次击穿空气对铝板放电产生多次波形,这同时也解释了随着模拟器接近速度的增加,主波形与二次波形之间的时间间隔减 小。 如图 8 和图 9 所示,二次波形的形状与主波形 一致,上升时间与主波形相近,二次波形电流峰值 达到 13.8 A,可能对设备造成二次损伤或累积效应。

结语

对地空气式 ESD 试验中,±2±4±6 kV 放电电 压的放电电流峰值及变化趋势与 IEC 61000-4-2 标准一致,上升时间趋于相同;但在±8±10±12 kV 放电电流峰值随放电电压的增大而减小,上升时间 随放电电压的增大而增大。

试验过程由于受激光传感器的限制,与传感器不在同一平面的障碍物无法检测。 对此,可以通过调整传感器高度,重复扫描环境以建立更准确的地图。

结语

所提出的基于图优化的 移动机器人 同步定位与地图构建算法,在仿真环境和实际环境中对算法 进行了验证。 传统粒子滤波优化方法需要维护全局地图中的所有粒子,随着地图范围的增大,需要维 护的粒子数增多, 对计算机的性能有较高的要求。 而图优化方法不需要地图中每一个粒子的信息,减少了累积误差,提高了有效性和鲁棒性。

Posted on

PB2018.10 使用全自动设置的管脚特定ESD软失效特性

下载PDF – 使用全自动设置的管脚特定ESD软失效特性

PIN SPECIFIC ESD SOFT FAILURE CHARACTERIZATION USING A FULLY AUTOMATED SET-UP

Abstract – A fully automated system is developed for the systematic characterization of soft failure robustness for a DUT. The methodology is founded on software-based detection methods and applied to a USB3 interface. The approach is extendable to other interfaces and measurement-based failure detection methods.

I. Introduction

In order to mitigate ESD-induced soft failures (SF) of a system, its robustness must first be evaluated. In light of the various parameters that influence the response of the system, it is best to use an automated characterization process. The outcome helps system-level and IC designers, and firmware developers.

The world of soft failures is diverse and has been studied in [1]-[8]. In this work, the device under test (DUT) is an Intel Joule 570x Internet of Things (IoT) platform. The USB3.0 interface was selected for characterization. USB3 related SFs were studied in [7]. Several disturbance methods were evaluated: system-level IEC, magnetic loop probe, conductive TLP injection, and directional injection. Soft failures were correlated to the stress parameters: the pulse rise time didn’t seem to affect the failure threshold, while pulse width was found to be inverse proportional to it. The authors found no correlation between CPU stress and failure modes, but no other DUT load was explored. Furthermore, the root-cause analysis of more severe modes were performed and a strategy for SF-SEED was proposed. This work confirms some of the earlier findings and extends others. The main idea is to develop a software-based method for an automated and systematic pinspecific characterization, and to explore methods for such data processing that can extract useful information.

The automated system is able to provide quantitative information on the dependence of different failure thresholds on the injected pulse level, polarity, rise time, system load and state, pin-to-pin variation, etc. Eight failure types across four severity levels were identified for the given system and failure dependence on various system loads was established.

II. Characterization Process

The TLP injection system by ESDEMC [9] was used to deliver repeatable pulses to the DUT. The TLP system combined with an oscilloscope allowed the injected currents and consequential voltages to be measured. The TLP was controlled through GPIB and COM interfaces to the “Control PC”, as shown in Figure 1.

Additional in-house software on the “Control PC” handled:

The detection and recognition of failure modes,

Sweeping of injected stress levels and polarities,

Controlling the DUT over secure shell (SSH) protocol through the network (either through cable – LAN, or WiFi – WLAN), and

Controlling other peripheral hardware (MCU).

A microcontroller unit (MCU), controlled over a serial interface, was used to switch two power relays: one for power cycling the DUT, another for tripping the power of the USB3 client device plugged into the host DUT port (interface under test).

A. Set-up description

1. Measurement set-up

The Intel Joule system consists of two separate parts – an expansion board and a compute module, as shown in Figure 2. The compute module contains all the key ICs (CPU, RAM, eMMC, Bluetooth, WiFi, etc.), while the expansion board provides power and fan-out to various interfaces (HDMI, microSD, USB3, USB-C, GPIO) with respective ESD protection devices. The compute module plugs into the expansion board through a 100-pin HiRose (HRS) surface-mount SF40 interconnect. In order to isolate the effects of the IC itself, rather than the effect of external ESD protection, an interposer board was developed. It was placed between the expansion board and the compute module, allowing injection of TLP pulses into the running (i.e., “hot”) USB3 interface data lines of the DUT, without significant loading of the USB3 signals. This was achieved by using lowcapacitance TVS diodes, an injection technique developed in [8]. The circuit is shown in Figure 3 and the board is shown in Figure 4.

In the current work, three pulse lengths were used in the robustness evaluation: 100 ns, 6 ns, and 2 ns. The injection and measurement setup for the 100 ns pulse is presented in Figure 5. Figure 6 shows the setup for the 6 ns and 2 ns injections.

For the 100 ns injected pulse width, a current probe and deconvolution code was used to capture the injected current; for short pulses, a pick-off T combined with a delay line were used to separate the incident and reflected pulses (vf-TLP method). The DUT and the peripheral hardware layout are depicted in Figure 7. The USB3 client device was a USB3.0 SanDisk memory stick. It is reasonable to expect that client-to-client variation will be minimal if TLP injection directionality is sufficiently high (i.e. the largest portion of the stress is injected towards the DUT, while the plugged in client experiences minimal stress).

2. Test Procedure for One Pulse

After calibrating the TLP injection and measurement system, the characterization procedure starts. For each injection level the following steps are taken:

1. Set the desired TLP voltage level;

2. Confirm that the DUT is in the “nominal” state (i.e. idle running and reporting);

3. Confirm that the interface under test is in the “nominal” state;

4. Inject a TLP pulse into the target pin;

5. Measure the waveforms and extract quasistatic voltage and current points;

6. Acquire kernel logs from the DUT;

7. Check if logs contain error messages;

8. Check if the interface under test is still in the “nominal” state;

9. If any abnormality is detected, classify and log the signature;

10. Detect soft failure mode;

11. Reset the USB interface to the nominal state (re-plug and check interface state);

12. If needed, reset the system to the nominal state;

13. Repeat for the next pulse level.

Each of the listed steps contains several sub-steps which complicate the characterization process. The full algorithm is discussed in the subsequent sections.

B. Automation Algorithm

The algorithm flow is almost fully depicted in Figure 8. The whole automated characterization process is run mostly from the “Control PC” by two separate software programs, along with an additional software program running on the DUT. One is the TLP software, and another is an inhouse Python script. Voltage level, polarity, number of pulses, and number of injections for each level are set in the TLP graphical user interface. The TLP GUI also controls each injection and measurement, calibration, and current deconvolution. Upon a successful TLP injection, the GUI reports measured data to the Python script via an interface ASCII file, and proceeds to wait until the next injection is initiated. A “successful TLP injection” means that the current and voltage waveforms were measured without oscilloscope clipping and triggering problems. If clipping occurs, the TLP has to fire again in order for the scope to retrigger. This may cause system upsets without a proper V-I measurement. However, this happens only when the system transitions to a new stress injection level. Since each pulse is repeated ~100 times, sufficient information is collected to measure enough points for a quasi-static IV curve. Upon receiving the data from the TLP software, the Python script pulls the kernel logs from the DUT via the SSH interface. The DUT runs Ubuntu GNU/Linux operating system, so by running the dmesg command [15] and filtering for USB-related events with grep command, the algorithm is able to establish whether a USB-related SF has occurred or not.

Some difficulty in the algorthm arises in three areas:

1. Bringing the DUT and the interface under test into the “nominal” state at every pulse;

2. Making sure that connections to the DUT and peripheral hardware are correctly opened and closed.

3. Differentiating between certain failure types based on the recovery method when the log message is unclear (e.g., failures that have similar signatures, but one requires a reboot, while the other – a power cycle).

These complications are caused by the SF and often manifest in the following ways:

a disrupted connection to the DUT;

causing a lost connection to the DUT due to a reboot;

a need to reboot or power cycle the DUT to overcome the failure;

a SF occurs, but no kernel message appears in the logs; the USB client device must be replugged to re-establish connection and reevaluate the state of the DUT USB interface.

Obscurity of kernel messages can cause the algorithm to branch out and spend time “Detecting Soft Failure Type”, as depicted in Figure 9. The detection is rather simple: for each failure mode, there is a condition that needs to be satisfied. In the overall structure, there is a hierarchy of conditions that stack up from less severe to most severe. The left brach detects USB2 fallback-related failures, the right one detects USB3-related ones.

Because SF behavior varies somewhat randomly, each test is performed up to 100 times. The data points (TLP voltage, injected current, voltage, polarity, state of the system, SF type) from each test are recorded in a *.csv file and later processed by a Python script using Pandas (code library used for big data analysis) [13]. The multi-dimensional data analysis is aided by constructing pivot charts grouped by the desired characteristic (e.g., injected current, pulse width, rise time, etc.) and calculating how often an SF type has occurred for each variation.

III. Results

A. ESD Gun testing

The Intel Joule development system was mounted inside an enclosure and a series of ESD gun tests were carried out. The purpose of the tests is to establish the range of soft failures when systemlevel stress is applied to different parts of the DUT: a) shield of USB3 port, and b) DUT chassis. An ESD Gun, Noiseken ESS-2000 TC-815R, was used to inject impulses in the range between 1 kV and 9kV, in contact discharge mode. The DUT and the injection points are shown in Figure 10. Each injection was repeated 100 times, while the operator monitored and logged occurring soft failures. Discharging into the DUT chassis (point 1 in Figure 10) was relatively robust, causing the HDMI screen to flicker several times at higher discharge voltages, but having no reported USB failures. Screen flicker is a kind of SF within the system, but unrelated to the USB3 interface, so it is not discussed in detail.

The results of the ESD gun testing for system-level stress injected into the USB3 shield are shown in the Figure 11. Most of the soft failures are related to the HDMI screen (flickering, tinting with colors, screen turning off until HDMI cable replug). USB3 soft failures occur after 6kV, with a likelihood of

B. Soft Failure Classification

Observed soft failures can be categorized sufficiently well by Table 1 from [7], repeated here as Table 1. Category “A” is the least severe – the user does not notice the effect of failure and no intervention is required on their side. Category “B” is noticeable, but the system recovers without intervention (data transfer speed drops, the system reconnects to the client device, etc.). Category “C” is most severe and encompasses a varied family of failures, which may require as little as re-plugging the client device and as much as completely power cycling the DUT.

The failure modes observed for the DUT mostly fall in the most severe category C. The full list and corresponding descriptions are in Table 2.

The most common SF is “USB3 re-enumeration” (Mode 2), which means that the DUT has reestablished the connection with the client device without user intervention; in this case, USB3 functionality is preserved and no further action is required. Sometimes this failure mode is accompanied by a GUI error message which requires user interaction, making this variation a Category C failure. The next failure mode variation is “fallback to USB2” (Mode 3). It occurs as a result of negative current injection and requires user intervention. The milder case requires a mere re-plugging of the client device; a more serious case requires system reboot or power cycling. These take much longer than a re-plug: 60-90 seconds to reboot vs 5 seconds to re-plug, which may be a major inconvenience to the operator. In case of positive high-current injections, a rare failure occurs that disables the USB interface and requires re-plugging, rebooting or power cycling (Mode 4). Occasionally, Wi-Fi functionality is lost (Mode 5), but no correlation between injection level and its occurrence has been established.

The worst case for modern hand-held and wearable devices is the soft failure that requires physically disconnecting the power. For portable devices that would mean taking out and re-placing the battery or flipping a physical switch. Neither of these are an option for different design and policy reasons (waterproofing, warranty, security, etc.). This makes the requirements for such failures to be more stringent than less severe failure modes.

C. Variation of Pulse Length

The results for the Sandisk USB client for 2, 6, and 100 ns pulse width stresses are shown in Figures 12-14 respectively. The pulse levels are swept from -70 V to +170 V. The assymetry is explained by the high risk of hard failure if the negative stress is pushed to higher levels (at least for longpulse case). The vertical axis is the likelihood of soft failure occurrence in percent; i.e., how often a particular SF has occurred out of all injected pulses for each particular pulse level and width.

The horizontal axis is the TLP charge voltage. As expected, at lower injection levels, no failures occur. For all cases, there seems to be a threshold, beyond which SF probability jumps from 0% to a substantial amount (between 50% and 80%). For lower duration pulses, this threshold is higher due to lower amount of energy delivered into the system. There seems to be little to no occurrence of serious soft failures for positive injections across the board. For positive current injections, only USB3 re-enumeration errors were observed. This is consistent across DUTs and other configurations. Only one case for the 100 ns injection had a somewhat severe fail – fallback to USB2, requiring the client to be re-plugged.

Negative current injections have a lower threshold and a richer variety of severe failure modes. USB enumeration failure rates are very small for short pulses, but increase to 53% from 0% at -50V TLP injection for 100 ns disturbance. However, the most interesting observation is that enumeration errors fall in frequency

D. Variation of DUT System State

One of the parameters of interest is soft failure occurrence under different system load conditions. There is prior evidence that the CPU load doesn’t have a significant influence on the likelihood of failure [7]. In this work, additional load conditions are explored by using a package stress-ng [14]. The package fully loads a 4-core CPU by using FFT function, reading and writing to RAM and eMMC. This load increases noise within the system, causing it to draw ~2x higher current and increasing overall system temperature. Hence, there is reasonable expectation that soft failures become more frequent, or more severe overall.

Ideally, one would repeat the full parametric sweep for each load condition. That increases characterization time many fold and is largely unnecessary, as baseline tests already show that no failures occur at lower injection levels. Therefore, in the interest of time conservation, only the threshold region for the positive injection sweep is selected for characterization under various load conditions. The results are shown in Figure 15.

The failure threshold stress current is the same for all cases and the occurrence levels vary between approximately 50% and 80%. Marginal variation from load to load is observed (within 10%). This confirms that the CPU load has only a weak influence on soft failure occurrence. RAM and eMMC loading shows similar results.

It must be noted that the DUT load condition sweep was not automated in this case, but automation is possible with reasonably small effort. For this, during the stage “Set DUT State” in Figure 8, the operator defines several Linux command-line interface commands to be swept (one for each test condition) and one overarching loop is added that re-runs the algorithm for different load conditions.

IV. Discussion

The scope of this work is in automating the characterization flow and in expanding the knowledge about soft failure occurrence in complex systems. The root cause of specific soft failures is still being actively researched [3-6]. Specifically, with USB3 [7] [8] it has been found that more severe failures (fallback to USB2, etc.) occur due to power domain disturbances, while errors in data transmission are overwhelmingly consistent with lower-level pulses, where stress waveforms increase the signal peak-to-peak voltage.

One can draw practical conclusions from the obtained characterization data. From the expected ESD levels and the coupling paths, the designer can estimate the safe current waveforms and levels. These can be compared to the failure probability data from the IC characterization.

The system developer may establish a probability threshold for each failure mode and use the method for a “pass/fail” evaluation. Depending on the product purpose, 20% failure rate may be acceptable for SF not requiring operator intervention

If soft failures are grouped, an envelope may be used to check the satisfaction of the passing criteria, e.g. “Max Envelope” on Figures 12-14.

A drawback of continuous, extensive TLP testing (especially with longer pulses) is the risk of “wearing out” the interface under test. This means introducing latent hardware failures by applying numerous pulses that under normal circumstances would not cause physical harm to the DUT.

Once the DUT is well characterized, the system designer can use that information to “get it right the first time” and/or reduce the number of product development iterations:

1.Make system design changes to mitigate some SF (system-, circuit-, and IC-level). This is especially beneficial in the early design stages of a product, when a designer is able to introduce additional protection, filtering, shielding, etc.

2.Make firmware or software improvements that would reduce severity or frequency of specific failure modes.

In cases that require inclusion of a measurement-based method (e.g. spike in current consumption of the interface) [4] [11] [12], at first it should be tested independently to establish the reliability and efficacy of the measurement method. Once the clear detection criteria are established, a function within “Detect SF Type” in Figure 9 can check if the criterion for detecting the SF has been satisfied. In order to adapt this characterization method to a different interface, at first exploratory work must be done to establish the variety of soft failure modes. Then hardware and software efforts are carried out. In terms of hardware – auxiliary boards may need to be designed to facilitate replugging, power cycling the interface of interest, etc. In terms of software – a function set within “Detect SF Type” must be written. These functions inquire and establish whether the criteria for SF detection have been met. In addition, interface initialization functions may require change. The rest of the algorithm largely remains the same.

V. Conclusion

An automated system for SF robustness characterization was developed and applied to a USB3 interface of an existing development platform for a number of stress pulse lengths and system load conditions. Test results were processed and soft failure occurrence likelihood statistics were obtained for various levels of TLP injections, and both polarities. In the scope of this work, software-based detection methods were utilized, but the methodology is extendable to other interfaces and measurement-based failure detection methods as well.

The methodology has a wide application range, but is possibly most useful for high-reliability systems that could not tolerate soft failures. One of the directions for further research is a deeper investigation into SF occurrence depending on system states (CPU load, GPU load, etc.) and a wider range of disturbances. Characterization and data processing methods are well established and may be extended for further study.

Acknowledgements

The material is based upon work supported by the National Science Foundation, Grant IIP-1440110. The authors would like to thank Nicholas Erickson of Missouri S&T EMC Laboratory for constructive criticism of the manuscript.

Posted on

PB2018.06 磁饱和网络变压器非线性模型建立

下载PDF – 磁饱和网络变压器非线性模型建立

摘要: 为了研究外界信号经过变压器后的输入输出特性,基于变压器的高频特性和磁饱和特性,提出了一种变压器的非线性电路模型建立方法,并进行了验证。变压器的高频特性表现为电路模型的寄生参数,构成变压器模型的线性部分。磁饱和特性表现为电路模型的可饱和磁芯参数,构成变压器模型的非线性部分。变压器模型的线性参数和非线性参数可通过实验测量的方法获取。该模型能够预判网络变压器在电缆放电等非正常大信号注入时的输入输出特性。 

关键词: 网络变压器;高频等效模型;磁饱和;B-H曲线

0引言

网络变压器作为网络接口的重要部件,其作用是将物理层传递的信号与网络接口传递的信号进行电隔离,防止内外干扰,提高传输的可靠性,并且可以滤除噪声,抑制共模干扰。在变压器的选取上,不仅要保证信号传输的完整性,还要考虑在受到外界干扰例如静电放电时,其输入输出特性对设备造成的影响。文献[1]发现网络接口终端物理层集成电路( integrated circuitIC) 的失效等级与磁组件的结构有密切关系。文献[2]发现变压器的饱和能够抑制传递到物理层 IC 端的总能量。文献[3]在研究变压器饱和对交直流电网直流电流分布的影响时,发现变压器的饱和特性对变压器中性点直流电流有助增作用。

目前,部分文献已经对变压器高频等效模型的建立进行了研究,用于分析变压器的趋肤效应、杂散电容等因素对信号传输的影响[ 6]。这些模型虽然考虑了变压器的阻抗特性随传输信号频率的变化,以及绕组漏电感和绕组间电容等因素对传输特性的影响,但是却忽略了变压器磁芯的饱和特性。

文献[7]利用最小二乘法拟合磁化曲线,并通过不同激磁电流下各次谐波的叠加来表征变压器的非线性,但由于谐波在进行叠加时存在一定的误差,因此,该模型并不能准确地反映变压器的饱和特性。 文献[8]忽略激磁电阻,通过代表激磁电流的诺顿等效电流源与非线性元件并联,对变压器励磁回路的 饱和进行表征,但是其对磁化曲线进行拟合的计算过程十分繁琐,且会出现不收敛的问题。文献[9]采用Jiles-Atherton( J-A) 理论模拟磁滞回线,通过确定磁芯材料的相关参数,求解材料磁化密度随外场变 化的关系来反映变压器的磁芯饱和。该数学方法非常适合数值计算,广泛应用于电路模拟,但是其计算 过程中的参数不易获得。Spice 软件的磁芯元件库采用了 J-A 模型,通过对磁心模型磁化曲线 ( magnetization curveB-H 曲线进行修改得到所需 B-H 曲线,通过参数提取就可以得到 J-A 模型参数。 因此,在 Spice 软件的 Model Editor 模块中直接输入测量的 B-H 曲线数据和其他参数,即可对变压器的磁芯进行定义。

本文建立了一种基于高频特性和磁饱和特性的变压器非线性电路模型。根据变压器的物理特性, 通过矢量网络分析仪( vector network analyzerVNA) 、数字电桥等仪器设备,测量变压器的高频特性参数及磁芯的 B-H 曲线,对变压器可饱和电路模型的建立进行了研究。对比 VNA 测量和电路模型仿真结果,进行了模型的频域验证。使用传输线脉冲( transmission line pulseTLP) 注入的方法,对模型进行了时域验证。

变压器高频等效参数提取

结合变压器低频等效模型,并考虑漏电感、磁芯损耗和分布电容等寄生参数的影响,建立了 N 1 变压器的高频等效电路模型,如图 1 所示。图 1 : 1为输入端; 2为输出端; L 为初级绕组电感; C1 C2分别为初级绕组电容和次级绕组电容; C 为绕组间电容; Rc为磁芯损耗电阻; R1 R2分别为初级绕组  1 N 1 变压器的高频等效电路模型 损耗电阻和次级绕组损耗电阻; L1 L2分别为初级漏电感和次级漏电感; N 1 为原线圈和副线圈的匝数比。

文献[10  11]对变压器线性模型的建立方法做了说明。 本文基于电路中两端口网络理论,通过 VNA 和电感电容电 ( inductancecapacitanceresistanceLCR) 数字电桥实验提 取高频等效模型中的参数。由于在本文研究的 1  1 变压器 中,导线在磁芯上的绕组方式为在相同的起止位置共同绕 组,因此,可认为变压器的初级绕组结构和次级绕组结构具有对称性。变压器高频等效参数的测量 集中在初级绕组电感 L、初级绕组电容 C1、磁芯损耗电阻 Rc、初级漏电感 L1、绕组间电容 C 和初级绕 组损耗电阻 R1。变压器线性参数测量装置如图 2 所示。装置 a 可以对参数 LC1RcL1进行测量,见  2a; 装置 b 可以对参数 C 进行测量,见图 2b; 装置 c 可以对参数 R1进行测量,见图 2c

1 1 装置 a 中各参数的测量方法

将变压器初级绕组的两个端口分别焊接在微带线端口处和 SMA 接地脚上,保持其他端口和中心抽头处于开路状态,测量变压器端口 1 和端口 3 之间的参数S11,将测量的 S11 参数转换为 Z11 参数,如  3 所示。图 3a  Z11 参数虚部,图 3b  Z11 参数相位。

使用 Z11 参数计算初级绕组电感 L、初级绕组电容 C1和磁芯损耗电阻 Rc,计算公式[2]为:

选择 Z11 的相位为 90°的频段( 100  300 kHz) ,将计算出的电感取平均值,即为初级绕组电感 L 选择 Z11 的相位为  90°的频段( 10  100 MHz) ,将计算出的电容取平均值,即为初级绕组电容 C1。选  Z11 的相位为 0°的频率点( 2 65 MHz) ,计算值即为磁芯损耗电阻 Rc。计算结果显示: L = 0 001 H C1 = 4 5 pFRc = 21 000 Ω。将变压器的次级绕组短路,重新测量 S11 参数,使用 L 的计算公式,即可得 到初级漏电感 L1 = 0 04 mH

1 2 装置 b 中各参数的测量方法

将变压器的次级绕组端口全部在微带线截断处的一侧短路,次级绕组端口全部在微带线截断处的另一侧短路,测量两端口的 S21 参数。通过 S21 参数计算绕组间电容的公式[2]为:

选择频段 1  10 MHz 计算电容,结果显示绕组间电容 C = 17 pF

1 3 装置 c 中各参数的测量方法

 LCR 数字电桥测量参数调为 R,测量夹具的两个夹子分别接变压器初级绕组的两个端口,保持变压器其他端口及中心抽头的开路状态,读取电桥上的测量数据。结果显示变压器的初级绕组损耗电  R1 = 2 Ω

可饱和磁芯的 B-H 曲线获取

磁性材料磁特性的外部表现是材料的磁感应强度 B 和磁场强度 H 的关系。磁感应强度反映了运 动电荷被引入磁场中受到磁场力作用的性质。对于在磁场中运动的电荷,根据洛伦兹力计算公式可知 磁场对其的作用力。磁场强度沿场中任意闭合路径的线积分只与产生磁场的传导电流有关,与场中介质 无关。对于各项同性的磁介质,磁感应强度和磁场强度满足媒介的本构关系,磁导率用来表征磁性材料的 导磁能力。对于绕有通电导线的磁芯而言,当通过导线的电流增大时,磁场强度 H 增大,磁感应强度 B  随之增大,当 B 增大到某一较高数值后,其随 H 增大的幅度很小,即磁芯达到了饱和状态。

变压器的饱和非线性特性可以通过测量磁 芯的 B-H 曲线[12]进行表征。磁芯 B-H 曲线的测 量装置如图 4 所示。测量方法与图 2a 的方法类 似,不同的是,该装置给 VNA 增加了一个外部直流电源。直流电源与 20 Ω 的电阻串联,加载到 VNA 的直流输入端口,并用万用表测量加载到 VNA 的直流电流,这个直流电流经过 VNA 的输 出端口,作用到被测量的变压器上。当变压器的 初级绕组线圈上有电流流过时,会使原本不显磁 的磁芯产生感应磁场。在一定范围内,从 0 V 逐步增大外部直流电源的输出电压,使变压器初级绕组线圈上的通电电流增大,就能够观测到磁饱和现象。

 1 1 变压器为例,改变直流电源的输出大小,使万用表的电流读数从  496 mA 逐步增大到 496 mA,记录万用表的电流读数和 VNA 对应的 S 参数,计算每一个直流电流读数对应的变压器初级绕组电感L( Idc ) 

根据安培定律可知,对于被测的变压器,有:

其中: N 为变压器磁环上导线缠绕的匝数; Idc为加载的直流电流; leff为有限环路长度,且满足

磁感应强度从数值上可以看成是通过与该点磁力线垂直的小面积内单位面积的磁通量。对于均匀磁场,有:

其中: Aeff为有效磁通面积,满足

对于被测的 1 1 变压器,代入变压器磁芯尺寸: D 为外直径,为内直径,为高度,为绕组匝数。 对于每一个直流电流,有:

将初始电感与直流偏置的关系代入式( 7) ,即可获得 B-H 曲线。

再通过式( 8) 计算变压器磁芯的初始磁导率:

将测量的 B-H 曲线数据、有效磁通面积、有效环路面 积和初始磁导率输入到 Spice 软件中,对磁芯进行自定 义。变压器磁芯 B-H 曲线如图 5 所示。

由于软件中 B-H 曲线的模拟是采用直接输入数据的 方式,所以模拟的 B-H 曲线与实测计算出的曲线一致性 良好。

变压器非线性模型的建立与验证

最终获得的变压器非线性模型如图 6 所示。图 6 : K 为非线性磁芯模型; L1  L4 为绕组电感; “13”不再是所测量的电感 值,而是导线绕组的匝数。

通过还原测试电路的方式,将变压器 的输入阻抗以及传输线脉冲作为干扰源 时,对变压器输入输出响应进行对比,对电 路模型分别进行了频域验证和时域验证。

3 1 频域验证

对图 6 中变压器的电路模型初级绕组 侧的端口 1 和端口 3 之间加载一个交流源 Aac,次级绕组和中心抽头与参考信号地之间分别串联 1 TΩ 电阻,相当于开路状态。将仿真模拟和测量 计算的 Z11 参数进行对比,如图 7 所示。图 7 的对比结果显示: 100  300 MHz 时,仿真值和测量值基本匹配,但是波形在高频范围内有所差异,主要是由于测 量计算的线性参数范围都在 300 MHz 以内。

3 2 时域验证

使用传输线脉冲作为信号源,在时域验证变压器非线性电路模型的正确性。图 8 为磁组件的时域测量装置结构图。CT2 电流探头连接示波器测量变压器输入端的电流波形,变压器输出端一个端口连接示波器通道,测量输出端的电压波形。磁组件的时域验证结果波形对比如图 9 所示。

9a 为变压器输出端电压波形,图 9b  600 V TLP 信号源输入时的电流波形。当 TLP 信号源的输入端电压较低时,变压器表现为线性,将 TLP 信号源输 入变压器的矩形波脉冲传递到变压器的输出端,并且不改变波形的形状。由于测试装置中高倍数衰减 器的使用,导致示波器各通道噪声变大,使测量波形中的毛刺较大。随着信号源电压等级的升高,电压 和电流波形出现变化,变压器开始出现饱和现象。当变压器出现饱和时,磁组件输入端的电流迅速增 大,而输出电压迅速降低。随着信号源电压的增大,电压和电流波形出现突变的时间越来越早,变压器发生饱和的现象越来越明显。

由图 9 可看出测量和仿真的电流和电压波形对比结果显示出较好的一致性,特别是在上升沿、电 压电流波形峰值和饱和起始时间 3 个参数方面。但在饱和现象发生后,电压波形的下降沿和电流波形 的上升沿方面,测量和仿真的结果有所差别,主要是由于变压器的一些高频分量模拟的缺失和 B-H  线的测量与模拟的差异性。即使对于同一变压器而言,如果磁芯上导线绕组存在差异,潜在性地破坏了变压器绕组方式的对称性,这也是引起实际测量和高对称性等效电路的模拟结果存在差异的原因。

结论

当幅值较大、脉冲时间较长的传输线脉冲放电电流通过变压器的绕线时,由于变压器的磁芯导磁能 力有限,磁芯会发生饱和现象,变压器会出现暂态过电压、过电流,引起变压器输入输出两端电压电流剧 烈变化。当变压器出现饱和效应时,变压器输入端的电流迅速增大,而输出电压迅速降低。随着信号源电压的增大,饱和出现的时间越来越早。

Posted on

PB2017.12 基于阶跃响应的空气放电模式静电放电发生器校准方法

下载PDF – 基于阶跃响应的空气放电模式静电放电发生器校准方法

STEP-RESPONSE-BASED CALIBRATION METHOD FOR ESD GENERATORS IN THE AIR-DISCHARGE MODE

Abstract—The current IEC 61000-4-2 (2008) standard does not provide calibration specifications for electrostatic discharge (ESD) generators in the air-discharge mode. This is largely due to the well-known fact of poor repeatability in air-discharge measurements. This complicates identifying an acceptable tolerance range of a reference waveform for air discharge. The variability of the discharge waveforms is caused by variations in the spark length. A novel air-discharge calibration method is proposed, which avoids sparking. The method is based on measuring the step response of an ESD generator in the air-discharge mode using a mercurywetted relay. Possible nonlinear effects are identified during the contact-mode ESD simulator calibration at higher voltages; thus, in combination, an air-discharge calibration method is provided. This letter explains the method and shows excellent repeatability.

Index Terms—Air discharge, electrostatic discharge (ESD) generator calibration, ESD gun, step response.

关键词:空气放电、静电放电(ESD)发生器校准、静电放电枪、阶跃响应

I. INTRODUCTION

Electronic products must comply with IEC [1] and/or ISO [2] electrostatic discharge (ESD) immunity standards before entering markets. Contact discharge and air discharge are considered in these standards and have been analyzed in [3]– [6]. During contact-discharge measurement, the ESD generator (also known as “ESD gun”) tip contacts directly with the device under test (DUT). The discharge occurs when the internal relay of the ESD generator closes. In the air-discharge measurement, the internal relay is kept closed as the charged ESD generator approaches the DUT. The discharge in the air gap between the ESD generator tip and the DUT can occur when the distance reaches a certain length. The current-carrying charge carriers within the spark can either originate from surface processes or a result of gas discharge processes [7].

For contact discharge, the discharge current waveforms are highly repeatable because the high-voltage spark only occurs inside the ESD generator’s internal relay. Thus, it is possible to specify a standard waveform for the contact-discharge measurement. On the other hand, for ESD air-discharge measurements, it is well known that the current waveforms repeat poorly due to the variations of the spark resistance, which results from the variation of the spark length. The variations of the arc length are a result of the approach speed and the statistical time lag. The statistical time lag is affected by speed of approach, humidity, surface conditions, voltage, etc. [8]. Thus, it is difficult to define a reference current waveform for the air-discharge calibration.

To produce better repeatability in the air-discharge mode discharge current, two approaches exist.

1) Discharge at a spark length given by the Paschen equation [8]–[12]. This can be realized by slowly approaching the ESD generator, possibly combined with methods that reduce the statistical time lag. Here, strong ultraviolet light, high humidity, and graphite layers on the electrodes can be used. If this method is selected, the discharge waveforms will repeat well, especially above 5 kV. However, the current rise will be rather slow (e.g., 3 ns at 10 kV), as the long arc length leads to a slow drop in the arc resistance. The current rate of changes will be for voltages above 3 kV in the range of a few amperes per meter. Thus, the arc is stabilized at a low threat level. Most fine structure of the step response of the ESD generator and high-frequency components of the current waveform and fields will be suppressed by the slow drop of the arc resistance. Thus, the test is more determining the selection of the main RC components of the ESD generator. In addition, Ishida et al. proposed an air-discharge calibration method based on fixed-gap discharge [13]. The idea is to use a fixed gap to replace the varying distance between the ESD gun tip and the ESD target of the typical air-discharge measurement. The process used spark gaps from Paschen length down to one-third of Paschen length. The shorter strongly overvoltage gaps lead to fast rise times and high peak currents. As the spark length is fixed, the waveforms are repeatable. However, they are still influenced by the time-varying spark resistance. Another condition for this method to work is that the voltage rise, which is initiated by closing the internal relay, is much faster than the statistical time lag. Otherwise, it could happen that the discharge already occurs while the voltage is rising.

2) If a low voltage is used and the ESD generator approaches the ESD target fast, the arc resistance may approach an ideal step function. One would hope that its resistance changes from infinite to nearly zero in picoseconds. Achieving this would allow capturing the step response of the ESD generator. The problem is that the spark gap formed between the ESD target and the ESD generator tip does not act as an ideal switch even at fast approach speeds. Here, the method suggested in this letter improves this concept by using a mercury-wetted relay that approaches an ideal switch much better.

The approach presented in this letter avoids testing ESD generators in the actual air-discharge mode that have a spark at the tip. The proposed method measures the step response of the ESD generator in the air-discharge mode using a mercury-wetted relay. The details of the structure and the measurement setup are explained in the following sections. Human body discharge step response was also measured using the same mercury relay setup. In this measurement, the tester is first charged to certain voltage (1 kV) and then discharges with the mercury relay. The measured human body discharge waveform can serve as a reference for the air-discharge mode waveform for the air-discharge calibration.

II. STEP RESPONSE METHOD

A. Mercury-Wetted Relay

To measure a good approximation of the step response of the ESD generator, a mercury-wetted relay is mounted between the tip and the ESD current target. The additional structure has a length of 16.4 mm. It substitutes the actual spark (see Fig. 1). ESD current targets have a discharge pad at their center [1]. In this measurement, the discharge pad is replaced with the mercury relay, which is enclosed into an epoxy filled tube to ensure mechanical stability. The relay is activated once a permanent magnet is brought into its proximity.

B. Step Response Measurement for the ESD Gun

The mercury relay tube is screwed onto the center of the ESD target (see Fig. 2). The selected relay cannot withstand voltage higher than 2 kV, so measurements were performed at 1 kV.

An Agilent DSO81304A Oscilloscope was used in the measurement. Three ESD generators from different manufacturers were tested. They will be labeled as “ESDGUN1,” “ESDGUN2,” and “ESDGUN3” in the measurement results section.

C. Step Response Measurement for Human Metal Discharge

The event of human discharging via a hand-held metal (human metal model, HMM) forms the reference event for the IEC 61000-4-2 standard, and it can be tested how similar the step response of the air-discharge mode generators is to the HMM events. As shown in Fig. 3, the person is standing on an insulator and is connected to a high-voltage supply. The tester holds the air-discharge tip against the mercury relay when the step response is measured. The discharge current and transient field of two testers were measured; the text refers to them as “Person1” and “Person2.”

D. Transient Field Measurement

Previous research has shown that the transient fields of ESD generators in the contact mode differ strongly, especially in the higher frequency region [14]. The variation in the transient field often causes different equipment under test failure levels when using different ESD generators. Thus, the transient fields during a step response excitation were captured. Fig. 4 shows the setup of the transient field measurement. A shielded loop probe having a loop diameter of 1 cm is used for H-field measurement. The E-field sensor, which was shown in [15], is used in the measurement. The E-field sensor has a flat response from 2 MHz to 2 GHz. On the other hand, waveform deconvolution [16] is needed for the H-field data as the sensitivity of the loop probe drops at lower frequencies by 20 dB/dec. The H-field probe is good for up to 2 GHz. The transient fields at 10 and 40 cm distance from the ESD target center were measured. The discharge current, E-field, and H-field are recorded simultaneously. It should be noted that the transient field of the ESD generator discharge event is not rotationally symmetric [14]. The E/H fields in this setup were measured at different locations (see Fig. 4).

III. EXPERIMENT RESULTS

A. Repeatability

Achieving repeatability is the main challenge for every airdischarge calibration method. The mercury-wetted relay is the best possible approximation of an ideal switch; thus, it has achieved excellent repeatability in both human metal and ESD generator discharges. Fig. 5 illustrates the repeatability of the current measurement. The variation in the peak values are within ±1% with respect to the average peak value.

B. Discharge Current

The data shown in Fig. 6 compare ESD generators and discharges from people holding the air-discharge tip in their hand. The waveforms represent the step responses and the initial rise of all waveforms is similar. The rise time is determined by the “ideal switch” formed by the mercury relay, and it is also limited by the bandwidth of the oscilloscope. Since the ESD target shows ideal impedance up to 5 GHz, the measured discharge current data will be filtered by a 5-GHz first-order low-pass filter. The discharge current of ESDGUN1 in the contact-discharge mode (black dotted line) is also shown in Fig. 6.

Core findings from the discharge current comparison in Fig. 6 are the following.

1) The measurement method gives repeatable step response information that allows characterization of the ESD generators in the air-discharge mode without having any effect of an arc.

2) The peak values of these three generators varied between 6.4 and 7.8 A, which are well within ±15% of the average measured ESD generator peak values for a charge voltage of 1 kV (a larger sample size of ESD generators may show higher variations between ESD generators).

3) Comparing the 1 kV ESDGUN1 air-discharge step response (yellow solid line) to the contact-mode discharge (black dotted line) reveals a 2.6 A larger peak current value, which is partially explained by the difference in rise time. There is also significantly more charge in the initial peak of the step response. This agrees with the observation in [9]. The authors reported that the total charge of the air discharge is higher than the contact discharge in the same level. This can be explained by the fact that all metal parts downstream of the relay are not charged in the contact mode, but in the air-discharge mode, they are charged to the set voltage. The later parts of waveforms (after 10 ns) almost overlap. This results from having the same RC network for the contact mode and the step response.

4) The human metal ESD (“Person1” and “Person2”) showed larger current values of 7–8.2 A. This is caused by the local capacitance of the hand that is close to the grounded wall. This structure is bulkier than the tip region of most of the ESD generators leading to a higher current in the step response (see Fig. 3). The total charge of the human metal ESD was less than the total charge of the ESD generators. This is to be expected as in most of the cases, the capacitance of a human to ground is less than the 150 pF as specified in the ESD standard. Human-toground capacitances can be as low as 70 pF in a wood frame house [17]. For a given tribo charge value, the voltage on a human may reach double the value in a wooden frame house relative to the human standing (insulated) on a conductive floor.

5) All air-discharge ESD generators showed some ringing; each shows ringing at a different frequency. The human metal ESD does not show the double peak structure, which is (for historical reasons) part of the IEC standard’s reference waveform. It is known and has been reported many times that the human metal ESD only rarely shows the clear double-peak structure [18].

C. Transient Field Results

The setup of the field measurement is shown in Fig. 4. The following conclusions can be drawn from Fig. 7.

1) The peak field strength at 10 cm is between 4.5 and 5.5 kV/m at a 1 kV charge voltage. In a real air-discharge situation, one could not expect that the field strength increases linearly with voltage, as the rise time would typically increase with voltage.

2) The human metal ESD shows a much larger electric field in the later time of the waveform as a result of having a charged body. The ESD generators store the energy of the charged body in a discrete capacitor. Thus, these fields are not visible outside the ESD generator. Furthermore, the ground return path for an ESD generator and that of a charged human body is quite different. This may also contribute to the differences in Fig. 7.

3) The rise time is determined by the relay and the field sensors’ bandwidth (about 2 GHz); thus, it cannot be attributed to properties of the ESD generator.

The magnetic field data in Fig. 8 show that the peak values are in the range 9–11 A/m for the cases investigated at 1 kV, the rising edge is determined by the mercury relay, not by the ESD generators, and the H-field waveform shapes are similar to the corresponding discharge current waveforms at this distance.

IV. DISCUSSION

The air discharge is well known for its poor repeatability due to the variation of the spark length for approaching electrodes. Several attempts have been made in the hope of defining a calibration method for ESD generators in the air-discharge mode. Greatly improved repeatability can be achieved either by a fixed gap [13] or by only considering discharges at spark lengths defined by Paschen’s law. Although carefully controlling the experimental parameters such as approaching speed, humidity, and air pressure can improve repeatability, it is not possible to achieve the repeatability of the contact mode as long as a spark is part of the testing. The proposed method overcomes this by avoiding the arc and capturing the step response of the linear ESD generator. The measured currents and fields repeat well in the contact mode, such that differences between different brands of ESD generators become clearly visible. The data also indicate that the peak current variation between different brand ESD generators (sample size of only three) is in the same range (within ±15%) as accepted for the contact mode. As the spark is substituted by a relay, no useful rise-time measurement can be performed. We do not consider this as a disadvantage, as the rise time in air discharge is determined by the drop of the arc resistance, and the arc physics is independent of the specific model of the ESD generator used. Another concern is nonlinearity. If there are nonlinear elements in the system, such as a saturating ferrite, sparking to some floating metal, or simply a wrong highvoltage supply value, this will be detected in the contact-mode calibration. For that reason, we believe that the air-discharge calibration does not need to repeat the high-voltage testing. A description by step response is sufficient, as nonlinear problems would be detected during the contact-mode calibration.

V. CONCLUSION

A calibration method is proposed in this letter for ESD generator air-discharge measurement. The method is based on the step response, which is realized by using a mercury-wetted relay. The mercury relay measurements are highly repeatable, and it excludes any arc effects. Thus, the data show the effect of the ESD generator structure. This method has the potential to be a calibration method of the ESD generator in the air-discharge mode.

Posted on

PB2017.05 火花长度大于PASCHENS定律预测值的几何形状的ESD火花表现和建模

下载PDF – 火花长度大于PASCHENS定律预测值得几何形状的ESD火花表现和建模

ESD SPARK BEHAVIOR AND MODELING FOR GEOMETRIES HAVING SPARK LENGTHS GREATER THAN THE VALUE PREDICTED BY PASCHENS LAW

Abstract—The insulation of plastic enclosures provides protection against direct electrostatic discharge (ESD) discharges to the system inside. However, seams between plastic parts are often unavoidable. To increase the voltage at which an ESD will penetrate the structure of the seam can be modified. Four plastic arrangements are constructed to investigate the spark length and current derivatives and to understand the ESD spark behavior for geometries having spark lengths longer than the values predicted by Paschen’s law. A two to threefold increase of spark lengths was found for sparks guided by plastic surfaces compared to spark length expected from the Paschen value at the same voltage level. In spite of the longer path, a faster spark development is observed for sparks along the plastic surface. Plastic arrangements that provide detour and fold-back paths hardly reduced the total spark length. No significant effects of the plastic materials or the polarity were observed. The spark length increased as the (absolute humidity) Absolute humidity (AH) increased, and the current derivative decreased by about 20% as the spark length increased with (relative humidity) Relative humidity (RH) changing from 9% to 65% at 29 °C. The spark resistance is modeled by a modified Rompe and Weizel’s law, which distinguishes the spark development in the air and along the plastic surface.

Index Terms—Electrostatic discharge, modeling, spark.

关键词:静电放电、建模、火花

I. INTRODUCTION

One method to achieve ESD robust electronic system design is to prevent sparking into the system. This can be achieved by a sufficiently insulating barrier. While even 0.3-mm plastic is usually not penetrated by ESD up to 25 kV difficulties are introduced by seams between plastic parts and openings that expose the inner circuits. The design choice can influence the tightness of adjacent plastic parts, the plastic materials, the wall thickness, and the distance to the electronics. Further the designer can shape the seams of adjacent plastic parts such that detours lengthen the spark path, or introduce fold-back structures that force the spark to develop against the electrostatic field direction. This article analyzes the effect of such design choices and provides an improved simulation model for the spark resistance which also includes situations in which the spark develops parallel to plastic surfaces.

A good starting point is to remind ourselves of Paschen’s law. It describes the relation between the static breakdown voltage as a function of the gap distance for homogeneous fields,

where U is the voltage in kilovolt (kV) and d is the distance in centimeter (cm).

However, a few practical electrode arrangements offer a homogeneous field. They differ in the following aspects:

1) Electrodes, such as Printed circuit board (PCBs) may have sharp tips or edges.

2) The spark path maybe guided along plastic surfaces as the spark penetrates between adjacent plastic parts of the enclosure.

3) The IEC 61000-4-2 test standard asks to approach the (device under test) Device under test (DUT) while attempting to discharge to it, thus, this leads to a change of the electric field strength.

It is generally known that sharp electrodes and paths parallel to insulating surfaces increase the length the spark can bridge. Our study has shown that for the voltage range relevant to ESD these geometric factors can increase the length by twofold or more relative to the value predicted by Paschen’s law. For approaching electrodes the opposite can happen: the discharge occurs at distances less than the value predicted by the Paschen’s law. This discrepancy is explained by a delay of the onset of the spark due to the statistical time lag while the gap is closing due to the approach velocity. This phenomenon leads to spark lengths below the Paschen value, reduced rise times and larger peak values. For approaching electrodes, the spark resistance behavior and its simulation is well documented in the literature [1], [2]. However, the lack of information on the spark behavior for spark lengths longer than the values predicted by Paschen’s law requires more investigation. Spark lengths longer than Paschen’s value are certainly more likely for voltages exceeding 8 kV as the effect of sharp edges is more pronounced at higher voltages. Further plastic surfaces, metallic edges, sur face contaminations, and humidity will reduce the statistical time lag. With reduced statistical time lag it becomes unlikely to experience shortening of the spark length due to the interplay of the approaching speed and statistical time lag. To our knowledge there is no comprehensive study of the spark behavior for plastic enclosures in a voltage range relevant to ESD.

The main questions addressed in this contribution are: What is the distance that a spark will bridge if it is guided by insulating surfaces of different shapes? How large are the current derivatives? And how can the current rise be simulated for this type of geometries?

This knowledge can guide the designer in selecting gap shapes and geometries that maximize the voltage needed to breakdown through a gap into an enclosure. If the breakdown cannot be prevented, the simulation models will allow us estimating the peak current derivative, which has been shown to be strongly related to soft-failures in products [5].

II. MEASUREMENT SETUP AND RESULTS

A. Experimental Setup

The experimental setup allows us controlling and capturing the following parameters.

1) The charge voltage is set by the operator. The setup is limited to 25 kV. The ground of the high voltage supply is connected to the ground plane, which forms the transmission line’s return path. The ESD current target is also grounded, thus the voltage is applied between the tip and the ESD current target.

2) The electrode shape and the geometry of the plastic arrangement is set to allow us straight, detour, and reversing spark paths, see Fig. 3.

3) Four different types of plastic materials have been used.

4) Testing is performed inside a climate chamber. The climate chamber does not allow us changing the air pressure. However, it has been shown that the value predicted by Paschen’s law is proportional to the air pressure for typical values on earth’s surface, i.e., it is reasonable that the results for spark lengths longer than the Paschen’s value will scale proportionally with air pressure. The testing has been done at a height of 300 m above sea level at about 40% RH and 23 °C.

5) The setup measures the discharge current and the electrode distance in the moment of the spark. The discharge current is measured via a current sensor as described in IEC 61000-4-2.

6) For measuring the spark length the moving electrode is attached to a slider via insulating fiberglass, see Figs. 1 and 2. The slider’s position is captured using a resistive position sensor. The discharge current triggers an S/H circuit that records the position of the moving electrode in the moment of the discharge.

A 7.5 m, 165 Ω transmission line was selected as discharging structure to provide a long enough square pulse. A value of 165 Ω is used as a compromise between the impedance of 266 Ω derived from the peak current definition of the IEC 61000-4- 2 standard (3.75 A/kV), charged cable discharges and lower impedance seen for the discharge of body worn equipment [3].

If no plastic arrangement or a straight path arrangement [see Fig. 3(a) and (b)] is used then the spark length equals the distance between the moving electrode and the current sensor. If arrangements (c) or (d) are used then the extra length within the plastic arrangement needs to be added to the electrode distance to obtain the total length of the spark path.

In plastic enclosures different types of interfaces are used. Some are folded back to increase the length of the gap and to force the spark to propagate against the electrostatic field. This approach increases the voltage needed for breakdown. To reproduce a set of different interfaces, the plastic surface has been machined to be smooth and pressed tightly to reproduce the situation encountered on products. One might expect that a spark cannot penetrate the gap between two plastic parts that are pressed together. However, it is known that holes as small as 10 µm will allow us a spark to penetrate through a seam, thus machining the surfaces on a milling machine does not prevent sparking. The four different plastic arrangements used for this investigation are shown in Fig. 3. They differ in the path style and path length. Arrangement (a) and (b) offer a straight spark paths parallel to the electrostatic field. Arrangement (a) used 3.2 mm thick plastic parts, while arrangement (b) uses 6.4 mm thick plastic parts. Arrangement (c) is created by offsetting two stacked 3.2 mm plastic parts. This leads to a detour for the spark, in which it partially travels perpendicular to the electrostatic field. Arrangement (d) forces the spark to travel against the electrostatic field. The total path that the spark travels along the plastic surface is 7.3 mm for arrangement (d). To obtain the total spark length, the section the spark bridges between the electrode and the plastic arrangement needs to be added.

If the voltage is above the minimal breakdown voltage the spark will partially travel guided by the plastic, and then bridge the section from the plastic surface to the rounded electrode in air. The length ratio between these two sections of the total spark length, depends on the plastic arrangement and the voltage. This experiment used a flat electrode (from the ESD current target) directly behind the plastic arrangement and the air discharge ESD generator tip as moving electrode. During the experiment the voltage was set and the electrode was approached towards the plastic arrangement. The approach speed was less than 10 mm/sec. While this speed is much less than the typical speed during ESD testing, it was observed that increasing the approach speed did not affect the results strongly for experiments that included a plastic arrangement. This indicates that the plastic arrangements lead to short statistical time lags. A short statistical time lag will lead to a breakdown at the moment the gap distance is reduced to a length that allows us a breakdown [1], [6].

The current sensor captures the current waveform leading to a system bandwidth (scope + cables + target) of about 3 GHz. Besides the spark length and the waveform, the peak current derivative is analyzed. This parameter has been selected as it has been shown that the peak current derivative often correlates to soft-failure thresholds on electronic systems [5].

B. Spark Length

The experiments involved setting the plastic arrangement, the charge voltage, and then approaching the electrodes. Sparking occurred above a voltage determined by the plastic arrangement. The current and the electrode distance at the moment of the sparking were measured and analyzed. Fig. 4 shows the spark lengths for different arrangements. Additionally, spark lengths according to Paschen’s law are included as a reference. A second reference shown in Fig. 4, is the discharge distance between two razor blades, arranged at 90o. The spark lengths obtained without plastic arrangement are very close to the Paschen’s values. This behavior is expected, as the arrangement is similar to the requirement for Paschen’s law, thus this result can be seen as indication for the correctness of the voltage setting and spark length measurement.

On the other extreme, Fig. 4 shows the measured breakdown distances for the razor blade setup. Here, additional measures were needed to reduce corona at the corners of the blades. The blades have been encapsulated in rounded electrodes for all regions except the region in which the sparking occurs. In spite of these measures, corona occurring at the sparking location (the center of the blades front edge) prevented the measurement for voltages exceeding 10 kV in the razor blade arrangement.

Using 3.2 mm thick plastic [see Fig. 3(a)] the spark values increased by a factor of about 2 compared to the Paschen value. For example for 10 kV, the values increased from 2.8 to 6–6.3 mm. Results using the 6.4-mm thick plastic [see Fig. 3(b)] indicate a further increase of the distance the spark can bridge. For example the value at 10 kV increased to 6.5–7 mm.

Intuitively one may expect that forcing the spark to propagate perpendicular or even against the electrostatic field would significantly decrease the distance a spark can bridge. However, the data does not support this hypothesis. The reverse arrangement having a plastic guided path of 7.3 mm, the spark length is 9.8–10.5 mm. This falls into a similar range as the arrangement (b) having a straight plastic guided path of 6.4 mm. The distance between the ESD current target and the air discharge tip is reduced because of the detour and the fold-back.

The seemingly counterintuitive observation that even a spark path against the electrostatic field will only marginally reduce the bridged distance, can be resolved if one considers that the developing spark modifies the local field as the streamer advances as an electrode [6].

While the underlying physical processes may not be fully understood the results clearly show a strong increase of the spark length if the spark is guided by plastic surfaces. This indicates that thicker plastic walls, or detour and reverse arrangements may not achieve the expected result of preventing sparking.

C. Effect of the Plastic Material

Table I presents data on the effect of selecting different plastic materials investigated for 15 kV using arrangement (b). The data are typical for other voltages and arrangements and give evidence that the selection of the plastic material does not strongly influence the sparking behavior. However, an important effect common to all plastic materials, is that the plastic arrangements significantly reduce the rise time and increase the peak current derivative of the discharge current. The results repeated well, see Fig. 5. This indicates that effects of possible surface changes or charge accumulation over repeated testing do not influence the results significantly. This is probably a result of having short pulses that transfer charges of less than 5 µC.

Further evidence to this effect is given by a direct comparison of the discharge currents presented in Fig. 5. (The waveforms are obtained using an RC discharge network instead of the transmission line structure.) Similar discharge currents have been observed for different plastic materials indicating that the discharge currents are independent of the plastic material. This might be explained by the fact that all plastic materials investigated have a somewhat similar relative permittivity in the range of 2.4–3.7. The data shown in Fig. 5 are supported by measurements at from –18 to 15 kV. The second, more pronounced effect is a faster spark development for the cases in which the spark is along a plastic surface. While the reason for the faster spark development has not been clarified in this study, the data clearly give evidence that the current derivative is increased, thus, the likelihood of damage or upset by ESD may be increased by spark paths along plastic surfaces. However, it was observed that the total distance the spark needed to bridge, has been increased by at least twofold.

We did not observe a strong effect of the polarity. This can be explained by the rather symmetric setup used in this investigation. One electrode is formed by the flat ESD current sensor while the other electrode is formed by the rounded ESD simulator air discharge tip.

D. Current Derivative

As discussed in the introduction section it is known that approaching electrodes can lead to spark lengths much shorter than the value predicted by Paschen’s law. During the delayed onset of the spark, the electrodes continue to approach, which increases the field strength in the gap. Once the discharge is initiated, the spark resistance will drop faster due to the increased field strength. This will also result into large peak current derivatives that may reach values of 1000 A/ns or more [1]. However, a long statistical time lag is required for voltages exceeding 8 kV to reach such high current derivative values. This requires a quasi-homogeneous field, clean electrodes and dry air. Most spark gap topologies encountered during air discharge mode ESD testing on products do not fulfill these conditions, i.e., the statistical time lag will be short. Throughout all our measurements, the peak current derivative remained in the range of 3–10 A/ns. Care must be taken to generalize these numbers as they will certainly be influenced by the source impedance of the discharge arrangement which was set to 165 Ω. However, the values will remain much lower than the values published for spark lengths shorter than the Paschen’s value [1]. Thus, one can use this value range to estimate the current derivatives and consequently induced voltages during ESD testing.

After having shown that neither polarity nor the plastic material selection strongly influenced the spark behavior the attention is moved to the effect of the plastic arrangement on the current derivative. The scatter plot presented in Fig. 6 details the effect of the spark length on the current derivative for different voltages and plastic arrangements. Data points on the left side of Fig. 6 shows spark lengths equal to the Paschen’s length (no plastic). The peak current derivatives slightly reduced as the voltage was increased from 10 to 15 kV. The middle section from 6–8 mm spark length of Fig. 6 shows results for plastic arrangement (a) that allows us a straight spark [see Fig. 3(a)] guided by 3.2-mm plastic. Although the spark length has increased from about 2.8 to 6.2 mm for 10 kV, the peak current derivative increased on average by 2 A/ns. This again indicates that the plastic surface not only allows us the spark to bridge larger distances, but also confirms that the spark develops faster in spite of its longer length. The right section of the plot presents the data for the detour and the counter field arrangements [see Fig. 3(c) and (d)]. The data is only shown for 15 kV, as not all arrangement showed a breakdown at lower voltages. In spite of spark lengths of more than 10 mm (about 3× the Paschen’s value for 15 kV) the spark development led to peak current derivatives in the range of 5.5–8.5 A/ns.

In summary, we conclude that the peak current derivatives for spark lengths longer than the values predicted by Paschen’s are in the range of 3–10 A/ns. The plastic guided spark can bridge up to 3 times the distance predicted by the Paschen’s value. In spite of these longer distances, the spark develops faster, leading to moderately increased peak current derivatives.

E. Influence of the Humidity

An ESD is affected by humidity by three mechanisms: in high humidity, the tribo-chargining is reduced [8]–[10], the conductivity of many materials is increased, leading to a faster charge decay, and the statistical time lag is strongly reduced [1]. The measurements, shown in Fig. 7, were conducted in a climate chamber where the environmental conditions can be varied between a relative humidity of 9% to 65% in a temperature range of 24 °C to 29 °C. The 6.4-mm plastic [see Fig. 3(b)] is used for the presented data at the right of the figure. For sparks guided by the plastic surface, the overall effect of the humidity on the current derivative is not strong. The spark length increases from 9.1–9.3 to 10.5–11.1 mm at 15 kV as the AH increases from 0.003 to 0.019 kg/m3. The data at 12 and 15 kV both show that by increasing AH, the peak current derivative decreases as the spark length increases. Overall, humidity has a minor effect on the experimental results.

III. SIMULATION OF THE SPARK RESISTANCE

It has been shown that the spark resistance law from Rompe and Weizel predicts the maximal current derivative over a large range of voltages and spark lengths in the range of 1.5–25 kV [1], [2], [11],

Based on the measured discharges in air while trying to achieve a good match between simulation and measurement, the spark constant KR is typically selected in the range of 0.5–1e–4 m2/(V2 s). However, the shorter rise times observed for sparks guided by plastic, (shown in Figs. 5 and 6), indicate that the spark develops faster if it is guided by plastic surfaces. To maintain a good match between simulation and measurements the value of KR needs to be modified if the spark is guided by a plastic surface. As seen in Fig. 8, a value of about 4e–4 m2/(V2 s) is most suitable for predicting the spark resistance drop for plastic guided sparks.

A second aspect that needs to be considered is that the initial spark originating from an ESD simulator tip, may be partially in air, until it reaches the plastic surface. Thus, one needs to consider both the spark distance in air and the spark distance along the plastic surface. Rompe and Weizel’s spark resistance law needs to be modified to simulate these cases. This is achieved by introducing a weighting function:

where p is the portion of the spark along plastic, Kplastic is the constant for the section parallel to the plastic and Kair is the constant needed to describe the spark development for the section in the air. The best match was achieved when Kair = 0.7e − 4 m2 /(V2 s) is used to model the section not guided by plastic, and Kplastic = 5e − 4 m2 /(V2 s) is used for the plastic guided distance.

To apply the modified law one should take the following steps:

1) Know the maximal voltage one wants to protect for.

2) Know the length of the section that is parallel to the plastic. This can be obtained from the mechanical drawings.

3) Estimate the total length of the spark, based, e.g., on information shown in Fig. 3.

4) Subtract the plastic guided path length from the total spark length. This provides the length of the section of the spark which is in air.

Using this information the both sections of the spark path are calculated and the modified law can be applied.

Using this modified spark resistance law, discharge waveforms have been simulated and compared to measurements, (for a constant path length along the plastic, but varying path lengths in the air [see Fig. 9]). This is achieved by increasing the voltage beyond the minimal value required to spark along the plastic. If the voltage exceeds this minimum limit, the distance of the section in air will increase. In the experiment the spark length section in air was measured using the setup shown in Fig. 1.

The peak current derivative is an important parameter as it often determines the peak induced voltage. The peak current derivatives and associated spark lengths are shown in Table II.

The results shown in Fig. 9 and Table II indicate that the modified law can predict the current waveform and especially the peak current derivative for sparks that are partially guided along a plastic surface.

IV. CONCLUSION

This experimental investigation into spark distances, current rise times, and the modeling of the spark resistance showed that sparks guided along plastic surfaces can bridge distances two to three times longer than the distances predicted by Paschen’s law. The introduction of detour paths or paths against the electrostatic field did not increase the voltage needed to bridge a spark.

In spite of the longer spark path, a strongly reduced rise time was observed for sparks along plastic surfaces comparing discharges at the same voltage. This accelerated spark development requires a modification in Rompe and Weizel’s spark resistance law to allow us predicting the peak current derivative for arrangements in which the spark partially is guided by a plastic surface. Further the results indicate that using different types of plastic materials hardly affected the measured currents or sparking distance.

Increasing RH resulted in a longer spark and a slightly smaller current derivative. However, humidity was not a strongly influencing factor.

It is suggested that the seam structure of the plastic enclosure for the electronic system be carefully designed to increase the voltage at which ESD will penetrate into the system by providing detour paths or paths against the electrostatic field to allow us placing the electronics closer to the enclosure.

Posted on

PB2017.04 ESD防护器件HMM和TLP测试方法及性能评价

下载PDF – ESD防护器件HMM和TLP测试方法及性能评价

摘 要:人体–金属模型波形(HMM)和传输线脉冲(TLP)波形是静电放电防护器件测试时常用的注入波形。 针对静电放电(ESD)防护器件,介绍了这 2 种波形的测试方法。通过对同一型号瞬态电压抑制器进行测量,获取器件的瞬态波形、钳位电压、损伤阈值、瞬态阻抗等特性参数,并对结果进行分析比较。测试结果表明,基于 IEC 标准的 HMM测试所能得到的有效信息最少;基于 TLP 的 HMM 测试可直观得到被测器件的静电放电瞬态响应; TLP 矩形波测试结果的稳定性好,测量参数的可重复性高。

关键词:ESD 防护器件;瞬态电压抑制器;人体金属模型;传输线脉冲测试;IEC61000-4-2

0 引言

随着电子产品大规模和超大规模集成电路的发展,以及产品体积空间的缩小,电子设备的静电 防护技术面临着越来越大的挑战。在电子线路防静电设计时选择合适的静电放电防护器件,可以有效提高电子系统和产品的静电放电(ESD)抗扰度[1-5]。 对 ESD 防护器件性能进行检测和评价是选择器件 的重要方法。

目前,对 ESD 防护器件性能的测试方法中,应用较多的有人体金属模型(HMM)测试、传输线 脉冲(TLP)测试、人体模型(HBM)测试、直流 (DC)测试等。上述测试方法中,直流测试的结果 反映了器件的直流特性,而实际的静电放电是高电压、大电流的瞬态脉冲,直流测试难以反映 ESD 防护器件的 ESD 防护特性。ANSI-STM5.1[6]等标准规 定了 HBM 波形的元件级 ESD 敏感度测试方法,但 由于规定中 HBM 测试波形的上升沿时间在 2~10 ns 之间,以 HBM 波形测试器件的 ESD 性能,并不能很好地表征快上升沿(<1 ns)ESD 事件中器件的抗 扰度。此外,不同的测试仪所产生的 HBM 波形相 差较大,HBM 测试方法存在较多问题[7]。

IEC61000-4-2 标准[8]所规定的 HMM 波形是静 电放电测试的一种标准波形,通常用于检测电子设 备的系统级静电放电抗扰度。由于测试标准提出较 早,HMM 波形的接受度高,目前许多器件生产商 进行元件级静电放电抗扰度测试时,会采用 HMM 波形作为测试源波形。传输线脉冲测试是元件级静 电放电抗扰度研究中使用较多的测试方法[9-13]。自 1985 年英特尔的工程师首次利用传输线测试技术 来测量器件的静电放电特性后,越来越多的工程师 和学者开始使用 TLP 技术来测量 ESD 保护器件和三极管等半导体器件的 ESD 特性[14-17]。

对同一器件,不同测试方法得到的结论可能不同。在静电放电保护器件的测试中,如何根据实际 情况和测试需求恰当地选择测试方法,如何有效评 价保护器件的性能,如何根据测试结果选择合适的 ESD 保护器件,依旧是研究人员需要探讨的问题。

本文对 2 种常用的测试波形:HMM 波形和 TLP 波形所对应的 ESD 防护器件的检测方法进行了说 明。通过对同一型号瞬态电压抑制器进行测试,对 比 2 种检测波形的测试结果,分析了不同方法在评估 ESD 防护器件性能方面各自的优缺点。

1 测试方法及设置

HMM 波形的测试方法有 2 种:基于 IEC61000-4-2 的 HMM 测试和基于50 Ω 的 HMM 测 试[12]。这 2 种测试所采用的波形模块电路结构不同, 相同点在于当被测器件(DUT)为 2 Ω 电阻时,电流探头所测的 DUT 端的电流波形都符合 IEC61000-4-2 标准中规定的 HMM 波形参数。

基于 50 Ω 的 HMM 测试和 TLP 测试的测试方 法相同,而波形发生模块不同。基于 50 Ω 的 HMM 波形发生模块为电容和电阻等元件组成的电路模 块,TLP 的波形发生模块的基本单元为传输线。

  • 基于 IEC61000-4-2 的 HMM 测试方法

IEC61000-4-2 标准中规定了静电放电模拟器在 接触式放电时的 HMM 电流波形参数。在基于 IEC61000-4-2 的 HMM 测试中,测试人员首先设定 静电发生器的放电电压,然后采用人手持发生器放 电的方式,使放电尖端接触被测器件管脚,在同一电压下对被测器件连续注入多次放电脉冲(例如, 100 次)。放电过程结束后,通过检测器件的电特性来确定器件是否在放电过程中受到损伤[17]。

  • 基于 50 Ω 的 HMM 和 TLP 测试方法

本文进行基于 50 Ω 的 HMM 测试和 TLP 测试时,脉冲波形发生器使用 ESDEMC 公司生产的 ES620–50 脉冲发生器,发生器载有 HMM 波形模块 和 TLP 波形模块。

使用这2种测试方法对元件级的ESD测试结构 如图 1 所示。通过控制波形发生模块的充放电过程, 脉冲发生器产生并向 DUT 注入脉冲波形,测试系 统中所有连接电缆的特性阻抗均为 50 Ω。DUT 端口电压和流经 DUT 的电流通过电压和电流探头连接示波器进行测量。

每一个脉冲注入后,通过转换开关的控制,使 DUT 连接到电源测量单元(SMU)。SMU向 DUT 加载直流偏置电压,检测 DUT 上的直流漏电流, 通过漏电流的变化来判断脉冲注入是否引起了 DUT 的损伤或损坏。

  • 基于 50 Ω 的 HMM 和 TLP 测试设置

基于 50 Ω 的 HMM 测试中,逐步增大 HMM 波形发生模块的充电电压。模块的充电电压范围为 50~1 225 V,电压测量步长为 25 V。每次 HMM 波形注入后,SMU 对器件加载±1 V 的直流偏置电压, 测量对应的直流漏电流。

TLP 测试中,TLP 波形发生模块的充电电压范 围为 1~1 000 V。1~50 V 范围内电压测量步长为 1 V,通过较密集的测试点得到准确的器件开启电 压。50~1 000 V 范围内电压测量步长为 20 V,适当 增大步长可高效地测量被测器件。每次 TLP 波形注 入后,SMU 对器件加载±1 V 的直流偏置电压,测量对应的直流漏电流。使用的 TLP 脉冲的上升沿时 间约为 1 ns。选用脉冲宽度为 50、100、200 ns 的 TLP 脉冲波形对被测器件进行测试,以得到方波脉 冲宽度对测量结果的影响。

测试所用的示波器带宽为 1 GHz,最大采样频 率为 10 GHz。电压探头测量带宽为 1 GHz,电流 探头为 CT2 型号电流探头,有效测量带宽为 200 MHz。本文测试的 DUT 为某型号 TVS。

  • 测试结果

根据上述的测试方法,对同一型号的 TVS 器件 进行了测试,获取不同测试方法下器件的瞬态响应、 伏安特性曲线和损伤阈值。

  • 基于 IEC61000-4-2 的 HMM 测试结果

根据 HMM 测试后器件的电特性检测结果,当 静电放电模拟器的充电电压设置为 10 kV 时,测试后的器件阻抗由 1010级降低至 106级。因此,器件 在基于 IEC61000-4-2 的 HMM 测量中的损伤阈值电压等级为 10 kV。

该测试方法没有测量器件的瞬态响应波形。

  • 基于 50 Ω 的 HMM 测试结果

图 2 为 3个不同等级的充电电压(500 V, 1 000 V,1 500 V)下,TVS 瞬态电流和电压波形。

从图 2 中可以看出,TVS 的瞬态电流波形形状 与 IEC61000-4-2 标准所规定的 HMM 电流波形形状 类似,第 2个峰值后,电流随脉冲时间的增加而逐步降低,200 ns 后基本为 0。瞬态电压波形呈现出明显的钳位现象。从电压波形图中可看出,器件的 开启电压为 10 V。当器件两端电压降至 10 V 以下, 器件不再导通,电压波形在 10 V 处出现明显的下降拐点。

  • TLP 测试结果

测试中,TLP 脉冲宽度分别设置为 50、100、 200 ns,其中 100 ns 为工业界常用的 TLP 测试脉冲 宽度。图 3 为 100 ns TLP 测试中,TLP 源电压为 500 V 时的 TVS 瞬态波形图。

由于过冲的峰值相对于稳态电压的值很大,为 准确获取伏安曲线,测量时将脉冲峰值进行了消减 处理。电压波形的过冲可能来自于测试系统中电压采样的感抗影响,也可能来自 TVS 在未触发时自身的高阻过电压。

100 ns 的脉冲后,电压波形出现振荡,这是因 为脉冲发生系统的阻抗为 50 Ω,而被测器件导通后阻抗较小,约为 2 Ω 甚至更低,导致整个测试系统 的阻抗不匹配引起的反射。50 ns 和 200 ns 的瞬态波形与图 3 所示类似。

按照 TLP 测试的常用方法,取脉冲宽度 70%~90%时间段内的瞬态波形数据做平均,每施加 一个脉冲,获得一个坐标点,绘制伏安曲线,不同 脉冲宽度对应的正极性漏电流为图中的虚线,结果 如图 4 所示。

图 4 中,3 种脉冲宽度下,漏电流曲线都发生了偏折,偏折拐点的位置出现明显差异,脉冲宽度 越长,拐点对应的电流值越小。这说明被测器件的 损伤与所注入的脉冲能量有关,注入能量越大,器件出现失效的等级越低。

由伏安曲线可知,该 TVS 的开启电压为 10 V。 对比 3 种脉宽的测试结果可知,虽然伏安曲线所选伏安曲线出现了差异,这种差异性随着电压的增大越来越明显。

根据 TLP 的测试结果,还可绘制脉冲电压(U), 脉冲时间(T)与受试器件瞬态阻抗(R)间的 VTR 3D 关系图,如图 5 所示。由于其类似瀑布的形状, 所以也称之为瀑布图。从图 5 中可清晰的看出器件阻抗随时间和脉冲电压的变化情况。

  • 测试比较与讨论

下文从测试方法和测试结果 2个方面对 3 种测 量进行比较。比较的测试结果包括:损伤阈值、瞬态波形、伏安曲线、瞬态阻抗等。

  • 测试方法

基于 IEC61000-4-2 标准的 HMM 测试方法由于 采用手持静电枪的方式对器件注入放电波形,因此 测试结果受到静电枪接地电缆的摆放位置、人手持姿势、静电枪与被测器件之间角度位置等测试环境的影响。这些环境因素可能造成测试结果的差异性。 IEC61000-4-2 标准对放电电流波形的规定允许存在 30%的误差,细则并不完善[18-20],不同放电枪的放 电波形存在差异,这是导致测试结果存在差异性的重要原因。由于认为静电放电发生器能够较好地还原真实的静电放电事件,因此,这种测试方法能够 获得被测器件在真实静电放电中的损伤电压阈值。

基于 50 Ω 的 HMM 测试和 TLP 测试使用的测 试系统与测试方法相同,激励源波形不同。相比基 于 IEC61000-4-2 标准的 HMM 测试方法而言,该测 试系统的测试可重复性高,受测试环境的影响小, 可以提供可靠稳定的测试结果。当 DUT 不为 2 Ω 电阻时,基于 50 Ω 的 HMM 电流波形与基于 IEC 的 HMM 电流波形可能存在较大差异,测试结果也 可能不同。文献[21]对 HMM 波形的 2 种测试方法进行了深入的分析与比较。

  • 测试结果
    • 损伤阈值

表 1 统计了 3 种测试方法测试同一型号 TVS 器 件得到的电压和电流阈值。从表 1 中可以看出,基 于 IEC 的 HMM 测试得到的为放电枪的充电电压与器件损伤的关系,而基于 TLP 的 HMM 和 TLP 测试能够得到器件损伤时的端口电压和通过器件的电流,因此后 2 种测试方法能更直接地表征器件本身 的 ESD 敏感度特性。

  • 瞬态电流和电压波形

基于 IEC61000-4-2 标准的 HMM 测试没有测量 波形。对比图 2 和图 3 可以看出,基于 50 Ω 的 HMM测试和 TLP 测试的瞬态波形有很大的差别。

由于 TLP 测试中的脉冲是理想方波波形,所以 瞬态波形的任何变化都来自于被测器件。

从基于 50 Ω 的 HMM 测试获得的瞬态电压波 形中,可直接读出器件的钳位电压值,还可以得到 器件在类似实际 ESD 事件中的瞬态响应波形。比较 不同源电压等级下的瞬态电压波形还可以判断器件的钳位电压与测试源电压的关系。然而,由于 HMM 波形是随时间不断变化的,所以不能判断瞬态波形 的变化是源波形的变化,还是由被测器件引起的。

  • 伏安曲线和瞬态阻抗

比较后 2 种测试方法所得的伏安曲线(图 6) 可以看出,2种方法测量的TVS开启电压都为10 V, 且当器件的端电压

<20 V 时,各测试波形的伏安曲 线基本重合。不同之处主要在于高电压段的伏安曲 线,这是由于不同的源波形在同样电压时对器件注 入的能量是不同的,说明本文所选择测量的 TVS 器 件瞬态阻抗与注入功率(能量)有关。>

由瞬态电压、电流波形计算被测器件瞬态阻抗 –时间的波形图,得到器件的瞬态阻抗特性,可以帮 助工程师在设计 ESD 防护电路时选择合适的防护 器件。当发生静电放电时,ESD 防护器件为静电电流的主要泄放通路,因此防护器件阻抗需要在短时 间内降低到一定值。从图 6 中 2 种脉宽的 TLP 所得 的瞬态阻抗波形中可以看出,器件阻抗在 1 ns 内迅速减小至 2 Ω。100 ns TLP 和 200 ns TLP 的波形重 合,说明瞬态阻抗不受 TLP 脉冲宽度的影响。基于 50 Ω的HMM测试所得的瞬态阻抗随时间在不断变 化,并不稳定,这是由于 HMM 的电压和电流值随 时间不断变化造成的。100 ns 之后的阻抗振荡很大, 是因为放电电流减小到示波器的噪声等级,测量结果不再准确。

  • 结论
  • 基于 IEC 标准 HMM 测试方法为系统级静电放电测试的标准方法,适用于系统级的静电放电 检测,可用作体积规格较大的器件检测,不可测试晶圆级或小体积/小管脚的器件检测,测试可重复性 较差,测试结果可为器件在系统中使用时的损伤阈值提供参考,只能说明器件本身的 ESD 敏感度,不 能评估 ESD 防护器件的防护性能。
  • 基于 50 Ω 的 HMM 测试结果可直接表征器 件的瞬态响应,搭载不同测试夹具可测试不同体积 的器件和晶元硅片等。但由于系统阻抗不同,该方 法只是 IEC 标准中 HMM 波形的一种近似。
  • TLP 测试方法是目前较先进的器件和晶圆 级静电放电测试方法。TLP 测试的结果通过分析可 以得到许多器件的有用参量,是测量和表征半导体 器件静电放电防护性能的首选方法。

4)ESD 保护器件对 ESD 的防护性能可以通过:开启电压、钳位电压、损伤电流和电压阈值、瞬态阻抗等方面来进行评价。3 种测试方法所获取的损 伤阈值和伏安曲线存在差异性,这是因为本文所测 的 TVS 器件的损伤是热击穿引起的,不同测试条件下对器件所注入的总能量不同。

Posted on

TR002 PV模块二极管TLP测试报告

SEM image of die surface from ESD damaged PV bypass diode sample, melted metal and silicon observed

PDF版本下载: TR002_PV Module Diodes TLP Test Report

太阳能电池阵列中安装的旁路和阻塞二极管对潜在的静电放电(Electrostatic Discharge, ESD)事件非常敏感。该报告阐述了PV模块二极管ESD失效机理,给出了测试和分析该类二极管ESD失效的有效方法。报告提供了太阳能阵列制造商所提供的几种型号二极管的测试方法和结果,用于演示该测试方法的有效性。

(Wei Huang, Jerry Tichenor, Yingjie Gan, David Pommerenke)

Posted on

TS002 基于TLP方法的电缆放电事件(CDE)自动化评估系统

下载PDF- Cable Discharge Event (CDE) Automated Test System Based on TLP Test Method

什么是CDE ? 电缆放电事件 (Cable Discharge Event ,CDE) 是电缆接头的金属部分和被接电缆接口或插口金属部分之间的静电放电。它是我们日常生活中非常常见的一种静电放电。

当CDE发生时,会产生瞬时大电流高电压脉冲,注入到接头引脚,可能引起系统的损伤。脉冲特性取决于电缆类型,电缆长度,电缆的物理摆放,被接接头系统特性和接头的内部电路结构。

作为电缆放电测试方案的拓荒者,ESDEMC公司在过去的三年中已经开发了数个电缆放电自动化测试系统。这里,我们想介绍我们最新的一类CDE测试系统,该测试系统是在我们最新的TLP-MUX系统的基础上研发的。

MUX代表复用器(Multiplexer), 用户可使用它,搭配我们的ES62X系列TLP系统(我们的首个 TLP-MUX设计方案可实现32管脚的自动化测试)进行多种设备的自动化测试。因此,该系统可实现不同线缆接口设计,例如USB,HDMI,VGA,DVI等接口的ESD可靠性测试和数据分析。

Posted on

PB2016.09 IEC 61000-4-2手机显示下降配置中的ESD测试

下载PDF – IEC 61000-4-2手机显示下降配置中的ESD测试

IEC 61000-4-2 ESD TEST IN DISPLAY DOWN CONFIGURATION FOR CELL PHONES

Abstract— During the IEC-61000-4-2 test the DUT is placed on a 0.5 mm insulating sheet, which is on the horizontal coupling plane(HCP). For discharge points on the back side of the phone this leads to a situation in which the display is facing the HCP. The phone or tablet  forms a capacitance between 50 pF and 300 pF to the HCP. The capacitance value depends on the size of the phone, its screen flatness, and the flatness of the insulator which may deteriorate over time. The discharges to the phone lead to a large displacement current flow through the display. This current has multiple paths to the body of the phone: via the touch electronics, via the display electronics and directly to the body of the phone. As these currents can reach 30A(at 8 kV contact mode), they can lead to upset and damage of both the display and the touch layers. This paper provides analysis of the display down test situation in order to show reproducibiliby problems. The effect of the capacitance variation is shown by the measurement and the PSPICE model. Full-wave model was used to help understand how much of the total current flows through the body of the phone. The Lichtenberg dust figure method was used to show the contribution of the corona discharge.

Keywords— Electrostatic discharge, mobile phone, display, IEC-61000-4-2

关键词:静电放电、移动电话、显示、IEC-61000-4-2

I.INTRODUCTION

Improving display and touch screen technology is often associated with thinner glass and smaller structure size. The displays have to pass ESD testing and test levels of 25 kV are not uncommon, especially if they may be used in an automotive environment. The IEC 61000-4-2 test standard instructs placing the DUT onto a 0.5 mm insulating sheet, which is placed on the horizontal coupling plane [3]. For discharge points on the back side of the phone this leads to a situation in which the display is facing the HCP. The phone forms a capacitance to the HCP in the range of 50-300 pF. This leads to a large displacement current flowing though the display. At 8 kV in contact mode the current reaches 30 A. The current flows through the top glass as displacement current and distributes as conduction current between the touch screen, display, and body of the phone. Improved technologies for displays aim at strengthening the top glass, which increases its dielectric constant, and producing thinner displays which also increases the current for sparkless discharge to the display. Further, smaller touch structures and a higher pixel count in the display increases the likelihood of fused touch traces, and damaged or upset of the display layers or the associated LCD driver ICs or mainboard ICs.

Every immunity test aims at reproducing a real-world situation in the laboratory to ensure robustness against the selected situation. For a cell phone it is an unlikely situation that it would be placed display down on a flat, metallic surface since most surfaces phones are placed on are neither metallic nor flat. However, the large capacitance between the phone and the flat surface leads to the fact that the initial current of the ESD pulse (3.75 A/kV according to the standard for contact mode) is nearly fully injected into the phone and passes on as displacement current through the phone. This geometry is hardly found in reality, but the present implementation of the test inhibits progress in display and touch technology [1-2].

The paper cannot completely describe the current flow and the parameters dependent on this test situation because of the complexity of phones and tablets and the variability in test situations, but it illustrates aspects of the set-up which may be novel.

II.UPSIDE DOWN MEASUREMENT SET-UP

The general set-up situation is shown in Fig. 1. The phone is placed on the HCP. The discharge to the body of the phone will force displacement current from the body of the phone to the HCP, and via the resistive/inductive networks of the display and the touch layers to the HCP. The currents depend strongly on the flatness of the insulating layer. The phone will reach a high voltage relative to the HCP. The final voltage depends on the capacitance ratio of the phone to the HCP, the ESD generator capacitance, and the capacitance value the HCP has to its surroundings. Nevertheless, for high test voltages the voltage between the HCP and the phone is large enough to cause corona discharge on the insulating layer which is explained in section III of this paper.

III.MEASUREMENT RESULTS

A. Discharge Current Measurement

The DUT is placed flat on the insulating layer and pressed down during the test to achieve a constant capacitance value, and to ensure that the distance to the HCP is 0.5 mm. In other cases the DUT is placed partially on a spacer (tilt configuration) to change the capacitance between the phone and the HCP, shown in Fig. 2. The measured capacitances for those two cases are 65 pF and 30 pF, respectively; the peak current versus voltage is shown in Fig. 3.

The discharge current is measured using an F65 current clamp, connected to a well-shielded oscilloscope. Both contact discharge mode and the air discharge mode are used for the measurement, shown in Fig. 4 and Fig. 5. The tilt configuration measurement waveform is presented to show the effect of possible corona discharge. In the flat configuration, in which the displacement current is larger, the contribution of the corona current to the total current may be invisible. The difference of the current due to the capacitance variation by the flat/tilt arrangement is shown in section IV. When the peak current is analyzed, there is a linear relationship between the peak current and the charge voltage for contact mode. This may sound obvious as this seems to be a direct result of the contact mode circuit definition. However, if at higher voltages the corona current would significantly contribute to the peak discharge current, the peak current would increase in a nonlinear fashion: It would increase faster than the voltage because of the contribution of the corona current. In measurement we observed a nonlinear current rise around 20 ns after the peak which indicates corona discharge, as shown in Fig. 4. Corona is a process that does not repeat well, this will also lead to the low repeatability of test results if the response of the display is affected by the corona. Thus, test setups which are prone to corona should be avoided. In general, corona caused by surface discharges on the thin plastic layer covering the HCP needs to be considered for higher voltage ESD.

For air discharge the additional parameter of the arc length will complicate the analysis. The arc length will vary from discharge to discharge even if the same voltage is used, thus, the current rise will vary [4-6]. In this case only Lichtenberg dust figures allow to identify the charge deposition caused by the corona, see Fig. 7 and Fig. 8.

B. Corona Discharge

An additional problem arises from surface discharges on the top surface of the insulating material, shown in Fig. 6. These surface discharges will cause additional currents at the edge of the phone and can spread multiple centimeters away from the phone.

The charges deposited on the surface can be visualized by using the Lichtenberg dust figure method [6-8]. An example of such charge deposition measured at 25 kV is shown in Fig. 7 and Fig. 8. The surface discharge begins at around 20 ns after the initial pulse and, according to the measured data, adds tens of Ampere which can increase the likelihood of fused bridges in the touch screen layer and other damages or upsets in the touch and the display.

 

The corona discharges form tree-like structures. Their propagation velocity is about 1 mm/ns and they can contribute to multiple amperes of additional currents. A detailed photo is shown in Fig. 8.

IV.SIMULATION

A. Full-Wave Model of the Upside Down Test

The full-wave model of the upside down test helps to understand the current flow in a more detailed LCD structure. Here, the final goal is to model the display, including its inner structure, the flex cable connections, and the first level of I/O on the phone. However, this publication only shows the first steps, which also include the touch structure. A general overview of the simulation domain is shown in Fig. 9. The HCP size and its distance to the ground plane (PEC plane) are proportionally reduced to maintain the HCP to ground capacitances. This proportional reduction maintains the capacitance ratios, but it does change the wave propagation on the HCP during the first nanoseconds of the discharge, such that this effect needs to be investigate. A variety of simplification, such as modeling the ITO layer by an equivalent thin sheet are verified using multiple simulations.

For the first 5 ns, until the reflected wave reaches the ESD generator, the HCP acts as infinite large ground plane. This is also verified by the measurement of currents for discharges to the ground and HCP, shown in Fig. 10. The downsized HCP cannot model the with respect to the wave propagation on top the HCP during the first nanoseconds. Although the difference is not large, it is better to use simulation data that is obtained by using an infinite large ground plane during the first nanoseconds, and then later use the simulation data that is dominated by the capacitance of the HCP, thus data obtained from a proportionally reduced HCP size.

The detailed phone model is shown in Fig. 11, the touch screen patches are connected by thin bridges for one orientation, and each array of the touch screen layer is connected to the main board using a 10 ohm resistor (30 in total), the total current through the touch screen is the summation of the current through each array.

An S-parameter voltage port substitutes the relay contact of the Noiseken ESD generator. The excitation signal at this port is a step function with fast rise which represents the rapid voltage collapse of the discharge process [8].

The simulated current distribution is shown in Fig. 12. This illustration compares the current at the tip and the current in all touch layer connections. The result is valid for this specific case, however, it is influenced by the glass thickness, touch structure, ITO layer conductivity, etc. Here, the full-wave model provides a numerical way to investigate the effect of those parameters and it allows simulating the current in the bridges which are prone to fusing due to the high current density. The numerical model had 9 billion cells before the lumping process [10] and the number of cells was reduced to 7 million which led to a simulation time of six hours for 40 ns on a computer having two Intel(R) Xeon(R) CPUs and 64 GB RAM installed. A GPU-based system will reduce the simulation time further, allowing more details of the display and the flex connection to be introduced.

The current distribution clearly indicates that the initial peak current is mainly flowing as displacement current through the glass directly into the body of the phone, while the later current is flowing into the touch layers. This is a result of the resistivity of the touch layers. It is known that the current flow in the touch layers can fuse the bridges (see Fig. 11). The simulation allows capturing the current in the bridges. The current in one of these currents path is shown in Fig13.

B. PSPICE Model of the Upside Down Test

The flatness of the insulating layer can have a significant effect on the discharge current. Two effects need to be considered: (1) because of the variation of the capacitance between the phone and the HCP, the total current can change;

(2) the current distribution can change as the areas with locally larger capacitance values will carry higher current. The effect of the capacitance has been investigated in both PSPICE simulation and measurements. Fig. 14 shows a circuit model that allows investigating the effect of capacitance variations between the phone and the HCP. The numerical modeling of the ESD generator is explained by [11]. For the first 5 ns, the HCP is shorted to ground, as the HCP acts as infinite large ground plane during this time frame. Later, the capacitance begins to dominate. Varying the value of the capacitance between the phone and the HCP (C4) from 40 pF to 300 pF affects the discharge current. With higher capacitance, the peak current reaches higher value and decays slower, as shown in Fig. 15. Section III indicated a similar behavior.

C. Comparison with the Measurement

The measured waveform (DUT pressed onto the insulator on the HCP, 8 kV) is compared with the full-wave simulation and the PSPICE result, shown in Fig.16. Both the full-wave and PSPICE simulation results are able to model the discharge current with respect to the peak current, rise time and the 30ns value within 20% tolerance. Thus the model can be used to investigate the aspects in the test setup which can lead to the variation of the current.

V.CONCLUSION

This paper analyzes aspects of the display down configuration for a cell phone in the IEC 61000-4-2 test. The paper shows measurement of linear and nonlinear behavior, including the surface corona which can increase the currents by multiple Ampere. It uses a long known (since 1776) method for visualization of surface discharges to demonstrate for the first time the effect of these surface discharges during upside down ESD testing.

It is further shown that the capacitance between the DUT and the HCP strongly affects the discharge current. This capacitance depends on the flatness of the insulator surface and is often not well controlled. Finally, the simulation of the current distribution in a touch layer obtained by full-wave simulation including the ESD generator, test set-up, cell phone and details of the touch layer, was presented.

The upside down test situation is somewhat unrealistic, as few phones or tablets will be placed on a flat metal surface in a display down position. Besides being unrealistic, the test set-up may also lead to difficult to reproduce results as the capacitance depends strongly on the thickness and flatness of the insulator used on the HCP.

VI.ACKNOWLEDGEMENT

This paper is based upon work supported partially by the National Science Foundation under Grant No. IIP-1440110.

Posted on

PB2016.09 使用替代PC板测量电流的显示器ESD

下载PDF – 使用替代PC板测量电流的显示器ESD

ESD TO THE DISPLAY INDUCING CURRENTS MEASURED USING A SUBSTITUTION PC BOARD

Abstract— ESD to a display may upset or damage the display or the touch circuit. The ESD may have a visible spark carrying current to the frame of the mobile device, to the connecting flex cable, or into the display by penetrating the glue between the glass layers. It may also be a sparkless ESD that causes corona charging on the surface of the glass have currents as high as 10 A. A measurement technique is presented that allows the measurement of the currents on all traces, including ground of flex cables that connect from the display to the main board of a mobile device. The main board is substituted to a PCB that has the same connections to the body of the mobile device and the same shape, i.e., the same electromagenic affects. However, all connections to the display are terminated in resistive structures that allow measuring the currents in the flex cable individually. Beside measuring ESD currents, the substitution board offers various other applications with respect to the coupling and propagation of self-interference causing signals or EMI problems.

Keywords: flex cable, LCD; mobile device; sparkless ESD; substitution board; touch-screen.

关键词:挠性电缆、液晶显示器、移动设备、无火花静电放电、替代板、触摸屏

I.INTRODUCTION

Electrostatic discharge (ESD) to portable electronic devices can cause hard and soft errors [1]-[3]. Typically in system level ESD testing, the ESD generator is discharged into the exposed metal parts of the DUT. The ESD generator voltage is incremented in steps and system level errors such as perturbation of the display, loss of touch functionality, system reset, etc. are monitored. Various measurement and modeling techniques have been used to study the effect of ESD discharge directly to different areas of the mobile device such as the main board reference ground, clock traces, power pins, metal chassis of the phone, and the LCD display [4]-[8]. The main limitation is that one notices a disturbance or damage to the ICs that connect to the display, but the currents that caused these effects are not known.

Sparkless ESD on the glass surface is the most likely ESD discharge to displays as cell phone design often provides sufficient isolation at the edges such that a discharge into the phone is not possible. These sparkless discharges [9] into an electronic product may also lead to various types of upsets and damages to ICs via induced current flow using any of the multiple coupling paths within the device, as shown in Fig. 1. Sparkless ESD to glass surfaces was studied in [9] and a method to visualize the surface charges using dust figures on the glass after a discharge event was analyzed in [10]. A discharge event on the glass may cause current coupling to the touch screen matrix and then to the traces of the touch controller IC on the flex cable. Similarly, current coupling to the LCD may induce currents to the LCD driver IC. The severity and type of upset/damage depends on the magnitude of the current flow to the sensitive ICs.

 

The measurement technique presented in this paper allows measuring the induced currents at the flex cable connectors on the substitution board due to an ESD discharge on the mobile phone screen/glass. These current values can help to understand the risk of damage to the driver IC or the display IC or disturbances of the data transfer. In some cases, ICs are mounted on the glass or the flex cable. In these cases the method will only measure the current that flows out of these ICs into the flex cable, as the measurement is done on the main board of the phone.

A substitution board is designed and fabricated to replace the main board of a mobile phone. Well shielded 0.8 mm diameter semi-rigid coaxial cables are used to probe the terminated flex traces individually on the substitution board. It must be noted that using multiple coaxial cables for probing also changes the electromagnetic behavior of the device being tested. These cables offer a path to ground. If ferrite clamps are not used on the coax cables, the cables act like a single ground connection similar to a short USB cable that would connect to a well-grounded system. The distribution of currents on the various I/O lines, flex cable shield, ground and power pins is obtained by this measurement technique. A contact mode discharge into a small copper patch on the glass was selected as the excitation because it approximates the sparkless discharges to the display from a current point of view. In contrast to a real arc it still is a linear system, as no arcing is involved in contact mode. We assume that the currents are strong enough to turn on all ESD protection within the ICs that are placed on the glass, such that only their dynamic resistance is visible. Testing at different voltages has verified the assumption of linear behavior.

II.DEVICE UNDER TEST: MOBILE PHONE

A four-layer PCB was designed for a mobile phone to demonstrate the substitution board methodology for measuring individual currents. The features of the phone that influence the electromagnetic behaviour of the phone (such as the main board ground structure, main board-to-phone body contact points, flex cable connector ground contacts, etc.) are identified and reproduced on the substitution board.

The details of the main board, its connections to the LCD and touch flex cables via board-to-board connectors, are shown in Fig. 2. The main board ground structure and its contact points to the mobile phone’s reference ground are shown in Fig. 3.

III.DESIGNED AND FABRICATED SUBSTITUTION BOARD

Based on the dimensions and ESD current flow relevant features of the mobile phone, a four-layer substitution board was designed and fabricated to replace the actual main board of the mobile phone. Fig. 4 shows the layout of the top layer of the substitution board. The board has the following main features:

Similar dimensions and thickness as that of the actual main board.

Similar ground structure and contact points to phone body as that of the actual main board.

Similar ground structure and contact points to phone body as that of the actual main board.

24-pin flex connector receptacle for connection to the LCD flex cable.

10-pin flex connector receptacle for connection to the touchscreen flex cable.

Pads for semi-rigid coax cable probing for all flex connector pins including ground connections.

Pads for resistive terminations for all flex connector pins including ground connections.

The ability to measure the current on the flex shield which is normally connected via a gasket to the main PCB ground.

IV.PROBING CIRCUIT & MEASUREMENT SETUP

Direct probing of the individual traces of the original main board and display flex cables was difficult because of the multilayer board design and thin flex traces. However, the substitution board allowed multiple probing coax cables. The currents in the individual traces of the flex cables were measured using well-shielded 0.8 mm diameter semi-rigid coaxial cables that are soldered on the pads that connect to the flex connector footprint via short (< 1 cm) transmission lines. The currents were measured in two different termination schemes depending on the assumption of the state of the ESD protection diodes on the main board ICs. The signal and I/O lines were loaded with the 50 ohm coax cables when the ESD protection was assumed to be turned off (scenario I). When the ESD protection was assumed to be turned on, the signal lines were terminated with a 1 ohm resistance (scenario II). In both the scenarios, each of the flex cable ground pins/connections was terminated with a 1 ohm resistance. The termination values were chosen as a compromise between the actual loading of the traces, and the ability to measure the currents well. The probing circuit diagram for scenario I and the termination circuit diagram showing all the signal and ground connections of the LCD and touchscreen flex connector are shown in Fig. 5 and Fig.6, respectively.

A photo of the substitution board mounted into the mobile phone’s body including the soldered semi-rigid coaxial cables and the connection of the touchscreen flex cable ground to the substitution board ground via a gasket is shown in Fig. 7.

The measurement set-up used for measuring the currents in the individual lines of the flex cable connectors on the substitution board for a discharge to a copper patch on the glass is shown in Fig. 8. The photo of the measurement set-up is shown in Fig. 9. The mobile phone with the substitution board and soldered semi-rigid coaxial cables is placed, with the display facing upwards, on a reference metal plate using a 1 cm thick Styrofoam spacer. Since the substitution PCB is well grounded by multiple coax cables, the height of the phone above the reference ground is not relevant. The currents were measured for discharges to a 2 cm x 2 cm copper patch on the glass in contact mode for three positive discharge voltages: 1 KV, 2 KV and 3 KV. The different voltages were selected to test the assumption of linearity which is based on the assumption that all ESD protection within the IC on the glass was turned on. As mentioned in the article, the discharge scenario is similar to sparkless discharges to the display [9]. Since there are 29 total coaxial probe outputs, the probe outputs were measured in sets of three. For each set of measurement, three probe outputs were connected to 50 ohm oscilloscope channels using an 8.7 V overvoltage protection device on each channel to limit the maximum voltage on the channel to 8.7 V. The rest of the coax outputs were terminated with 50 ohm each.

The discharge current into the patch was also measured simultaneously using an F65 current clamp, as shown in Fig. 10. The discharge current into the patch in each set of measurement was practically identical. The current clamp output was connected to the oscilloscope channel using a 20 dB attenuator and an overvoltage protection circuit clamping at 8.7 V.

V.RESULTS AND ANALYSIS

The main goal of the current measurements was to understand the relative distribution of currents within the mobile phone and on the various signals and ground connections of the flex cable for a discharge to the glass. The measured peak current magnitudes for scenario I and II on each of the different pins of the LCD and touchscreen flex cable connectors for all three discharge voltages are plotted in Fig. 11-Fig. 12 and Fig. 13- Fig. 14, respectively. As an example, the measured current waveforms for a set of measurements, in scenario I (50 Ohm termination for I/O), at the LCD and touchscreen flex cable connector for +1 KV discharge is shown in Fig. 17. The peak current plots in Fig. 11-Fig. 13 show that the currents in the LCD and touchscreen flex cable ground structures are more than 10 times larger than the currents that flow in the I/O lines while they are about 2-4 times larger for the case when each of the signal lines are terminated with a 1 ohm resistance.

Fig. 14 shows that most (1 A) of the peak patch current flows in the I/O (pin-9) on the touch flex connector when the patch is in the center of the glass. To investigate the dependence of the peak current on touch pin-9, the peak currents were measured for different positions of the patch, as shown in Fig. 15, effectively scanning the discharge location on the glass. The plot of the peak currents on touch pin-9 for different discharge positions on the glass, Fig. 16, indicates strong dependency of the peak current on the discharge location. The peak current magnitudes on the I/O lines might also cause various upset events in the actual system. Correlation of the currents measured using the substitution board to the upsets events on the actual mobile phone was not part of this study. However, the authors hope that the substitution board methodology can be used for such an investigation.

From the current comparisons, for scenario I and scenario II (Fig. 11 – Fig. 14), it can be inferred that the ESD protection turn on can significantly change the current paths within the phone and the current distribution between the I/O and ground pins. To obtain an approximate distribution of currents that flow into the flex cable and to the body of the phone via capacitive coupling after a discharge to the glass, all the measured currents on both the LCD and touchscreen flex cables were summed up and compared with the discharge current into the copper patch. The comparison between the patch current and summation of individual currents and the summation of the absolute magnitude of individual currents for scenario-I is shown in Fig. 18. The peak current magnitude of the discharge current is about 1.6 A and that of the summed-up currents is 1.2 A in scenario I.

VI.CONCLUSION

A measurement technique is presented that allows measuring the induced currents at the LCD and touchscreen flex cable connectors on a substitution board due to an ESD to the glass/screen of a mobile device. The design of a substitution board based on the EMC relevant features of the mobile device and the measurement set-up for measuring the currents on various I/O and ground connections individually was demonstrated. The use of multiple coaxial cables that are well connected to the reference plane presents a similar scenario as that of a mobile device connected by a single wide, short USB or charging cable. The resistive terminations for different lines are chosen so as to emulate the impedance of the actual main board terminations as close as possible. Here, one can change the values depending on the assumed status of the ESD protection at the IC I/Os. Preliminary measurements using the substitution board indicated that a large part of the discharge current flows to the PCB via the flex cables and a smaller part via capacitive coupling to the phone body. The current distribution may be different for different products. In addition, observations of the measured peak current magnitudes at various flex connector pins show that the turn on of the ESD protection circuits at the ICs I/O can significantly change the current paths within the phone. These ratios may be influenced by the status of the ESD protection circuits at the ICs I/O. The current values measured using the substitution board can help to understand damage to the driver IC or the display IC or disturbances of the data transfer and can be used to correlate the current magnitudes to system level effects. The applicability of the substitution board methodology is not limited to mobile devices and can be applied to other electronic products as well.

Besides measuring ESD currents the substitution board offers various other applications with respect to the coupling and propagation of self-interference causing signals or EMI problems.

VII.ACKNOWLEDGEMENT

This paper is based upon work supported partially by the National Science Foundation under Grant No. IIP-1440110.n

Posted on

PB2016.07 ESD电缆通过磁性向以太网收发器放电的系统级建模方法

下载PDF – ESD电缆通过磁性向以太网收发器放电的系统级建模方法

SYSTEM-LEVEL MODELING METHODOLOGY OF ESD CABLE DISCHARGE TO ETHERNET TRANSCEIVER THROUGH MAGNETICS

Abstract—When a charged cable is plugged into an Ethernet connector, a cable discharge event (CDE) will occur. Ethernet transceiver pins are often affected by CDE as they are usually unshielded. The discharge current couples via the transformer and common mode chokes to the physical layer-integrated circuit and may damage it. This paper describes a methodology for CDE system-level modeling in SPICE taking the cable geometry into account via full-wave modeling and cross-sectional analysis. A charged cable model, a nonlinear magnetics model, an Ethernet transceiver pin model, and the traces in the system are combined to create a complete model. An Ethernet system suffering cable discharge was selected to illustrate the methodology. The simulation is compared to measurements.

Index Terms—Cable discharge event (CDE), electrostatic discharge, Ethernet transmission line pulse (TLP), system efficient ESD design (SEED).

关键词:线缆放电事件(CDE)、静电放电、以太网传输线脉冲(TLP)、系统高效ESD设计(SEED)

I、. INTRODUCTION

Cable discharge event (CDE) robustness is a quality issue which network equipment designers should consider. Studies in [1]–[4] directly or indirectly determine the expected charge voltage, and studies in [5]–[7] give examples of possible discharge waveforms for a given voltage. Two CDE-producing situations can clearly be distinguished. The first is through triboelectric charging by pulling a cable over a surface. The authors of [2] reported voltages up to 1.7 kV in a setup that pulls cables from one spool to another while sliding the cable over insulating surfaces. In proprietary industry test standards, the use of 200 m LAN cable charged to 2 kV is suggested. The second scenario can be illustrated as follows. A person carries a laptop that is charged and inserts a LAN cable into the laptop. The voltage levels accumulated by a person can be derived from triboelectric charging by walking, sitting, and standing up from chairs or removing a garment [8]–[10] and can easily reach 10 kV or more.

When a charged cable is plugged into an Ethernet connector, the voltage and consequential current can damage the transformer, common mode chokes, and especially the Ethernet transceivers [1]. Because of the length of LAN cables, CDE discharges can be quite long and have the potential to stress the I/O more than those discharges described by the HBM or the IEC 61000-4-2 discharge model [4]. Most CDE will occur at voltages below 5 kV, leading to shorter rise rimes compared to the 0.85 ns of the IEC 61000-4-2 standard. These shorter rise times may require shorter turn on performance of the electrostatic discharge (ESD) protection circuit.

The electrostatic discharge association is now working on a CDE standard. However, no published CDE standard exits and complying with the system level IEC 61000-4-2 standard may not ensure sufficient robustness of a device or a system against CDE.

In order to characterize interface protection elements, the authors of many publications simulate or experimentally emulate cable discharge with long transmission lines [3]–[7]. The difficulty of creating a CDE standard test is complicated by the many parameters which influence the discharge, such as the charging and discharging mechanisms, pin mating sequence, cable geometry, height of the cable above ground, and the load conditions. In [4] and [11], CDE charging and discharging mechanisms were introduced. In [11], the effects of the pin mating sequence with respect to injecting a common and/or differential mode current were discussed. In [12], some effects of cable geometry were explained by a multibody capacitance model. Previous publications provide a basic understanding of the cable discharges, both from the theoretical and measurement’s point of view [11]– [13]. For system-level investigation, both a cable charging and discharging model need to be included. As many conductors are involved in LAN CDE, the model must be more complex than a single transmission line discharge scenario such as a transmission line pulse (TLP).

The Ethernet magnetic circuit is used to protect against noise, suppress common mode, and to provide galvanic isolation [14] and can come in several different configurations. The failure level of the PHY will depend on this magnetic module [15], which means that this magnetic circuit needs to be modeled correctly to understand its role in protecting the PHY. The performance of the magnetics depends not only on the winding inductances, but also on parasitic parameters such as leakage inductances and interwinding capacitances. In [16] and [17], the authors demonstrate examples linear magnetic modeling for such transformers. However, due to the large currents during an ESD event, nonlinear effects such as core saturation must be considered. Chiefly, the saturation of the magnetic cores can limit the amount of energy which is coupled into the transceiver circuit [18]. This requires a saturable B–H curve-based model [19], [20].

Finally, an Ethernet IC transceiver pin behavioral model is needed to predict its failure level during a discharge [21]. Such a model should be able to reproduce the VI curve behavior such that it can be used in simulation to model the pin [22]. A sudden strong change of the VI curve or an increase of the leakage current measured by a source measurement unit (SMU) is often regarded as an indication for the failure of the DUT [23]. The very fast transmission line pulse (VF-TLP) has been established as the best choice for the characterization of such VI curves and damage thresholds as it can also resolve the DUT behavior in the first nanoseconds of the stress stimulus.

This paper follows the concept of system efficient ESD design (SEED) [24] and uses a cable discharge system as an example to illustrate how to build the complete system-level model. Section II introduces the selected cable discharge system. Each part of the system modeling methods and results are shown in Section III. The models of each part were combined as a system circuit, and the comparison of simulation and measurement results is shown in Section IV. Section V discusses three situations which are not shown in the model. System level saturation situations, CDE versus ESD simulator discharging, and shielded cable influences are discussed in this section. Section VI presents the analysis of this modeling methodology.

II. CABLE DISCHARGE SYSTEM STRUCTURE

As shown in Fig. 1, the selected cable discharge system includes: 1) charged Cat 5 cable; 2) magnetic group with Ethernet connector; 3) interconnection between magnetics and Ethernet PHY IC; and 4) PHY IC transceiver media-dependent interface (MDI) pins. The primary-side center tap of the magnetics is connected to a Bob Smith termination circuit [25] which consists of a 75 Ω resistor and a 1 nF high voltage capacitor. This termination circuit is sometimes implemented using different component values. For example, if power over Ethernet is provided, the capacitor value may be much larger. Furthermore, many center taps from different pairs or even cables may connect together and share the same termination circuit. In this case, the secondary-side center tap is connected to ground through a 1 nF capacitor.

As this paper does not attempt to examine the specific charging processes which can lead to CDE, we simply assume that the cable was charged in common mode based on [2]; i.e., all eight conductors had the same voltage with respect to a ground reference plane. The first pin that contacts initiates a current flow into the LAN connector. This is referred to as a common mode discharge, as the current magnitude depends on the common mode impedance of the cable to ground and the common mode termination impedance on the other end of the cable (open circuit, for an unconnected cable). Although already described in [11], it is important to be reminded of the effect of PIN sequencing during the discharge of an unshielded LAN cable. In CDE, at least two different modes can be initiated by the second pin that mates. The second pin can either be from the same twisted pair as the first pin that contacted, or from another twisted pair. If it is from the same pair, a differential mode current will be initiated and the first pin will be the main return path of a differential current on this pair. In this case, the common mode chokes cannot suppress this differential mode current. Most discharge current will transfer to the PHY IC pins through the magnetics. As the differential discharge case forms the worst case scenario, it was selected as the basis for modeling.

III. MODELING METHODOLOGY

This cable discharge arrangement contains four parts; each part was simulated and tested separately, and then combined in the Allegro Design Entry CIS 16.6 SPICE solver.

A. Charged Cable Model

The charged cable model was built using CST Cable Studio’s hybrid method. The simulator analyzes the cable geometry by cross-sectional analysis and then places it into a 3-D solver to determine the effect of the surrounding on the cable currents. A geometric representation of the four twisted wire pairs (TWPs) of a Cat 5e cable 5 cm above the reference ground plane was first created and then the bundled to create the unshielded twisted pair geometry shown in Fig. 2. Placing a port on each side of all eight wires in the cable geometry results in a 16-port S-parameter matrix which represents the simulated cable. In practice, the wire pairs are twisted more closely together than in the simulated model but we are not aware of a method within CST to create such a closely bundled cable. Because the results shown in Sections III and IV indicate that the resulting error is acceptable, the super twisting of the cable bundle was not considered.

As the next step, the 16-port S-parameter file was converted to a circuit file using a commercial macro model generation tool [26]. This circuit file is suitable for the SPICE simulation as a 32 pin component.

Fig. 3 shows the cable charging and discharging circuit model. To experimentally verify the model, the ES631-LAN Ethernet CDE evaluation system provided by ESDEMC LLC was used. To reflect the inner structure of the CDE tester [27], two cables needed to be modeled. The 5.6 m long section is the external DUT and the 0.4 m long cable section is part of the CDE tester.

The cable charge voltage is set by the initial condition. The cable discharge sequence is determined by the voltage control switch S1 and the termination resistors on the right side in Fig. 3.

Although all wires are charged to the same voltage prior to the first contact, there will be a differential voltage after the first contact. This differential voltage will drive the possibly damaging differential current if the second pin that mates belongs to the same pair. The amount of the voltage depends on the ratio of the well-controlled wire-to-wire capacitance Cww of a pair and the capacitance of the second wire to ground Cwgnd . A simplified capacitive divider is shown in Fig. 4 to illustrate the charge redistribution after the first pin contacts. This is further analyzed in [28]. Measurements show that cables routed in a cable tray may have a capacitance ratio of Cww : Cwgnd up to 1:0.75. Thus, a common mode voltage caused by triboelectric charging of 2400 V will lead to a differential voltage of 1000 V after the first pin discharge.

To verify the cable model, simulated and measured results were compared for second pin discharge cases. The precharge differential voltage of the wire was set to 1 kV, and pin 1 and 2 (see Fig. 3) were shorted together to allow for differential current flow. The discharge current was measured using a CT2 current probe inside the CDE tester.

The results are shown in Fig. 5 together with currents simulated using a simple differential pair model having optimized per unit length parameters. This additional simulation has been performed as other publications have used a transmission line as approximation of the cable discharge pulse. The model consists of two differential lossy transmission lines connected in series. The long transmission line corresponds to the 5.6 m charge cable. Another short differential transmission line corresponds to the 0.4 m cable. The long transmission line was precharged to 1 kV. The switch is placed at the connection point of these transmission lines, similar to the cable model. The lossy transmission lines were defined by their per unit length parameters. In the model, L = 400 nH, C = 40 pF, R = {0.001 sqrt(2 s)}, G = 0 are used. R uses the Laplace variable “s” to model attenuation as a function of frequency. L and C have been derived from the propagation velocity and the characteristic impedance; the loss has been optimized for best match to the full cable model data. One can also use the method mentioned in [29] to create a twisted pair model.

As Fig. 5 shows, the differential currents which determine the discharge currents match well. The frequency of the current waveform oscillation is directly related to the cable propagation velocity and length. In this case, the 6 m total cable length corresponds to a pulse width of 60 ns. The measured data show more damping than the simulated data which is likely caused by additional losses in the CDE tester such as the discharge relays. From a damage point of view, the rise time, peak current, and duration of the first pulse measurement and simulation match.

However, when comparing the simulation using a differential transmission line to the multiwire model and additionally considering practical aspects in test implementation, one will realize that the differential transmission line is only a very good model for one specific case, and it loses generality if other pin sequences are analyzed.

For example, the first pin discharge current strongly depends on the height of the cable above ground; thus, it would require a TLP of adjustable characteristic impedance. A second case which is difficult to model by the differential transmission line is when the second pin to mate is part of a different twisted pair than the first. Experimentally, there is a fundamental difference between using a TLP to discharge to a pin and a differential transmission line discharge. The TLP is usually ground referenced; thus, it requires a high voltage pulse balun to attach the TLP such that a differential current is injected. Therefore, a full LAN CDE tester which has eight individual relays to model the pin mating sequences is preferable.

B. Magnetic Group Model

As shown in [15], the CDE performance depends on the type of Ethernet magnetics used in a product. A typical Ethernet magnetic circuit consists of a center tapped 1:1 isolation transformer and common mode chokes at the cable side and/or the physical (PHY) IC side. In the system investigated, the magnetic group contained three such magnetic components: a three-wire common mode choke at the PHY side, a balanced-to-balanced 1:1 transformer, and a two-wire common mode choke at the cable side (see Fig. 1). The magnetics are made from twisted wires, which form a twisted pair transmission line which is wrapped around a core (see Fig. 6). The 1:1 transformer was selected to illustrate this construction method. The Ethernet common mode chokes were created using the same method.

A linear 1:N transformer model usually contains parameters such as: primary and secondary winding inductance, primary and secondary winding capacitance, core loss resistance, leakage inductance, interwinding capacitance, primary and secondary loss resistance, among other characteristics.

Using a VNA and LCR meter, we obtained the linear parameters. Transformer linear parameter measurement theory and method are described in [30]. By measuring the transformer’s S-parameters, primary winding inductance L1 , primary winding capacitance C1 , core loss resistance RC , leakage inductance L5 , and interwinding capacitance C can be estimated by the equations in Table I. Primary and secondary loss resistance was obtained by measuring the resistance of the primary and secondary winding by LCR meter.

The B–H curve is needed to model the transformer’s nonlinear behavior. A measurement of the primary inductance L1 under different dc-bias currents is used to capture the change of the inductance as a function of dc current. To obtain the B–H curve, the initial permeability μi of the transformer toroidal core was determined from the initial inductance, the core size, and the number of turns (which is obtained from dissecting a transformer).

Allegro Design Entry CIS allows the user to define the magnetic core based on the Jiles–Atherton model [31] by directly importing the measured B–H curve data points to the model editor. Fig. 7 shows the B–H curve of the transformer core and the resultant nonlinear model.

The next step combines the two common mode choke models with the transformer model. The verification was performed in time domain using a TLP as the source (see Fig. 8). An oscilloscope was used to capture the output voltage at 50/100 Ω single/differential load and the input current is measured using a CT-2 probe. As the ac termination provides an additional current path in the real world, it was also added to the test circuit during the verification.

the verification. Fig. 9 compares simulation and measurement results for the input-side currents and the output-side voltages. At low-source voltage levels, the magnetic behavior is linear. The magnetics transfers the TLP pulse to the output side without distortion. However, as the injection source value increases, the nonlinearities begin to manifest. Saturation was first observed when the internal voltage source of the TLP is at approximately 600 V. At the onset of core saturation, the input current rapidly increases while the output voltage drops. Higher charge voltages lead to an earlier onset of saturation.

A comparison of the modeled and measured voltage and current waveforms shows very similar behaviors especially for the peak values and saturation onset time. Some differences are visible on the falling edges which could be explained by variation in material parameters from sample to sample, by the unmolded magnetic hysteresis, or similarly neglected frequency-dependent transformer parameters. Finally, it is known that even within one magnetic, the wire pairs have somewhat different behaviors, potentially due to subtle asymmetries in the geometry which can also contribute to differences between the real-world measurement and highly symmetric transformer equivalent circuit.

From the comparison of the simulation and measurements shown in Fig. 9, it can be seen that 100 ns 600 V excitation pulses inject 3 A into the primary side of the transformer and trigger saturation at 70% of the pulse width. Besides core material and size, the transformer saturation also depends on the secondary signals, but change to much lower impedances once the ESD protection circuits are triggered. Therefore, in order to simulate the system correctly, the transceiver pin impedances need to known side load. In the setup shown in Fig. 8, if the load was changed to 5 Ω saturation appears from 1400 V source voltage. In the application, the transformer is loaded by the Ethernet transceiver pins which provided a 50 Ω input impedance for in-band voltage.

C. Transceiver Pin Model

The PHY IC transceiver pin model consists of a linear and a nonlinear model. According to the VNA measurements, the parasitic parameters such as package inductance and input capacitance are rather small

The nonlinear transceiver pin model was obtained using the ES620 TLP VI-curve system from ESDEMC. Fig. 10 shows the test setup. To obtain the voltage and current waveforms during the first nanoseconds, the time-domain reflection (TDR) method was used [23]. In this method, the current is calculated from the forward and reflected waveforms. In order to distinguish the incident and reflected voltage waveforms, the TLP generator supply pulse width is limited by the length of the low loss coaxial cable which acts as a delay line. Using a 2 m long cable limited the TLP pulse width to less than 10 ns. The voltage at the pin side was measured by a 1 kΩ resistor. To gain direct access to the IC, the Ethernet connector and the magnetics were removed during the VI curve characterization. The PHY IC transceiver pin VI curve was measured in the unpowered state as it was known that this transceiver pin uses a dual diode protection circuit.

The leakage current was measured by the SMU B2961A after each pulse to identify if the I/O structure of the pin was damaged.

The VI curve was measured using an average window from 7 to 9 ns [23]. As the CDE pulse in the system level test is about 50 ns long, an additional VI curve measurement was performed using a TLP having 100 ns pulse length. Here, the average window was set to 70–90 ns. Both measurements yielded similar VI curves indicating that the VI curve of this dual diode-based protection structure is independent of the averaging window.

The VI curve was modeled by voltage-controlled switches, ideal diodes, and resistors where the resistors and switches were used to set the VI characteristics and the ideal diodes separate the positive and negative injection behaviors. Fig. 11 compares the IC transceiver pin modeling and measurement result. As expected in a dual diode protection, the turn-on voltage is about 0.7 V if not powered, and the curve is symmetric with respect to polarity. The diode’s dynamic resistance is about 0.4 Ω after turned on. Applying 1.6 V Vdd IC shifts the positive VI curve branch shift by 1.6 V.

Changes in leakage current are generally used as an indication of whether the IO pin has been damaged. During VF-TLP (10 ns pulse width), the leakage current was measured after each pulse by applying 1 V dc to the pin. The leakage current did not change. It remained at 300 μA for currents up to 40 A. Using a 100 ns wide pulse damage was observed at 23 A as indicated by an increase of the leakage current from 300 μA to 10 mA.

D. Traces and Other Influencing Factors

The traces between the Ethernet connector and PHY IC pins form a differential transmission line. Using a TDR, the trace length and impedance were determined. It is important not only to consider the inductance formed by the common mode choke, but to consider the fact that the common mode choke is made by winding a TWP around the core. Its electrical parameter also had been determined using a differential mode TDR. The effect of the pair is modeled as T1 and T2. Fig. 12 gives details of the traces and common mode choke transmission line modeling structure.

IV. SYSTEM-LEVEL MODELING RESULT

The model was completed by combining the cable model, the magnetic model, the interconnection, and the IC model. Fig. 13 compares the measured and simulated results for the second pin (pin 1) discharge case. A differential voltage of 1000 V was used and the current waveform was measured at the I_probe branch (see Fig. 3). The voltage waveform was measured at the MDI+ pin via a 1 k resistor, corresponding to the voltage at PHY-side node of inductor L3 (see Fig. 12).

Voltage overshoot and ringing is visible at the waveform shown in Fig. 13. For small signal levels, the PHY IC terminates the differential pair into 50 Ω to ground. However, if the signal levels are large enough to turn on the ESD protection of the PHY IC, the signal is reflected by the low dynamic resistance of the ESD protection (about 0.4 Ω). The ringing is caused by this reflection and the traces and inductances between the IC and the transformer.

V. DISCUSSION

A. Transformer Saturation

The first aspect to discuss is the effect of saturation of the transformer core and the common mode chokes. The chokes will not be saturated by differential signals, but long pulses or high current levels will saturate the transformer. This effectively reduces the IC current, protecting the IC. The transformer investigated began to saturate at 3 kV if a 5.6 m cable was used. Using a 25 m cable, saturation was observed above 1 kV (see Fig. 14). The saturation onset occurs at rather high currents which are caused by the low dynamic impedance of the ESD protection circuit (0.4 Ω). The large current in the secondary winding partially cancels the flux caused by the primary winding and in this way, preventing core saturation. As the saturation is reducing the current in the ESD protection, it is important to model saturation for predicting the CDE robustness of the system.

B. Comparing CDE to IEC 61000-4-2 Contact Mode Discharge

As CDE test equipment [32] is presently not widely available, it is common practice to test the robustness of equipment against CDE by using an IEC 61000-4-2 generator in contact mode. The IEC 61000-4-2 ESD generator is discharged to individual pins of the connector while the other pins are left unconnected. Simulations using the proposed model help to clarify the differences and similarities between a dedicated CDE tester and an ESD simulator.

As shown in Fig. 15, the ESD generator directly discharges to a LAN connector pin. The current flows via the common mode choke, and one half of the transformer to the 75 Ω – 1 nF termination circuit. This current, and the resulting voltages at the Ethernet PHY IC are compared to a discharge from a LAN cable in differential mode, i.e., to the case in which the second pin which contacts belongs to the same pair.

Here, an ESD generator charge voltage of 4 kV is assumed. For the discharge of the LAN cable, 1 kV differential voltage is used for the simulation. The ESD generator circuit model is taken from [22].

Comparing the CDE tester to the ESD generator shows clear differences between the measured current and voltage waveforms (see Fig. 16). The data indicate that a 1 kV CDE differential (second pin) discharge causes a peak current value of approximately 15 A, which is similar to the peak current caused by an ESD generator charged to 4 kV and discharged to the pin in contact mode.

The pulse lengths cannot be directly compared as the CDE pulse depends on the length of the LAN cable length. A 1:4 voltage ratio approximately matches the peak current which can be estimated by simply analyzing the impedance ratios. The CDE differential discharge has a source impedance of about 100 Ω (LAN cable); the approximate source impedance of an IEC 61000-4-2 generator can be estimated from the requirement of having 3.75 A/kV peak current which leads to about 266 Ω. Further, the 75 Ω of the ac termination must be included for the ESD generator discharge leading to an impedance ratio of 100:341. However, the fundamental difference in the return current path should not be overlooked. First, the second pin discharge of a LAN cable drives a differential current, which passes unaffected through the common mode chokes. In contrast, the ESD generator discharge current is not compensated within the common mode choke; thus, the choke will partially suppress the current up to the point of saturation.

An additional difference results from a large variation in circuit implementation of the ac termination circuit which carries the bulk of the return current when an ESD generator is used for testing. In this case, the circuit is implemented by a 1 nF capacitor and 75 Ω resistor connected in series from the transformer center tap to VSS. Because the connection method and component selection for this termination circuit varies strongly between products (e.g., multiple center taps may be connected to one termination, varying RC values, or a simply nonexistent termination), the ESD generator can see significantly different load impedances which are unrealistic during real CDEs. Therefore, it is recommended that IEC 61000-4-2 compliant generators not be used for evaluating the CDE robustness of the Ethernet front-ends.

C. Shielded LAN Cables

Cable discharge of a multiwire cable is a complex situation and the current depends on many parameters, such as the mating sequence, the distance of the cable to ground, the charge voltage and the response of the different linear and nonlinear components inside the product. If the cable is shielded, additional parameters need to be considered. If the cable is charged by applying a voltage to the shield and the shield contacts first, a discharge will occur between shield and the system ground. In this case, the discharge is not likely to cause damage, as the voltage between the shield and the wires would be very low. However, the quality of market sampled cables varies strongly. The best cables use both a foil and a braid and connect them well to the connector shield. However, some “shielded” cables have no shield at all, and some use only a rather resistive foil which does not make reliable contact with the connector. Thus, an analysis of “shielded cables” would have to include a discussion on the quality of the shield implementation-based cables sampled from the market.

VI. CONCLUSION

This paper introduced a system-level modeling method for the electrostatic discharge of LAN cables. An Ethernet-connected system was chosen to illustrate the modeling method. Four main parts are included in the simulation model: charged cable, transformer and common mode choke arrangement, including saturation, traces in the system, and the nonlinear response of the Ethernet transceiver’s ESD protection circuit. The pins of the connector connect in a random sequence. A differential mode discharge will occur if the first and the second pin which contact are from the same twisted pair. This connection sequence may lead to the worst case discharge. This differential mode current can damage the physical layer-integrated circuit. It is further shown that the saturation of the transformer can help to protect the IC, and that testing for CDE robustness by using an IEC 61000-4-2 generator is not a good substitute for a CDE tester as the return current path for the IEC 61000-4-2 testing does not match the current path of the differential discharge. The methodology proposed in this paper provides a step toward a complete SEED simulation of LAN cable discharges.

Posted on

TN003_CN 基于IEC61000-4-2和ISO10605标准的静电放电(ESD)模拟发生器的校准

TN003_P01 ESD Simulator Calibration setup

下载ESDEMC_TN003_CN 基于IEC61000-4-2和ISO10605标准的静电放电(ESD)模拟发生器的校准(PDF)

1. 目的及意义

本文旨在提供ESD模拟发生器的校准参数和性能校验方法,并将校验结果与IEC 61000-4-2和ISO10605标准的规定值进行对比。

2. 校准要求与设备

2.1 ESD模拟发生器电压校验

IEC61000-4-2(2008)和ISO10605(2008)都指出,静电放电发生器的端电压,或者静电放电模拟器的高压源都需要使用高压表或者静电电压表进行校验。
表1 ESD模拟器放电端/高压电源电压校验范围

  IEC61000-4-2(2008) ISO10605(2008)
电压校准 ± 15 kV ± 25 kV
误差范围 < ± 5% < ± 5%

当使用接触式高压表 (>100 G Ohm的输入阻抗)进行校准时, 需要让高压源对放电端进行持续的充电,以保持电压电位,否则高压表会使放电端放电,导致电压读数慢慢减小。ESDEMC公司的ES105-100高阻抗高压表能够满足高压校准的要求 (>100 G Ohm 的输入阻抗,能够测试高达100 kV的电压,并且误差小于 2%)。
由于ESD模拟发生器的放电端尖锐且放电点小,放电端和非接触式静电计之间的容性耦合很弱,因此低于± 5%的误差范围很难实现。并且,大多数高精度非接触式静电电压表不能够测量高达±25 kV的静电电压。这就需要放电端和非接触式静电计探头之间有较强的耦合。ESDEMC公司的ES102振动电容静电计符合高压校准(具有高达1kV自校准能力的非接触式测量)的要求。该静电计具有已校准的外部高压源和较强的容性耦合,能够测量200V至200kV的静电电压,并且误差率小于2%。

2.2 接触式放电模式的放电电流校验

IEC61000-4-2(2008)和ISO10605(2008)都规定了ESD接触模式放电电流的波形。波形需要满足的具体要求如下表2所示。
表2 接触模式下放电电流波形参数标准要求

标准 IEC61000-4-2(2008) ISO10605(2008)

 

RC网络数值 150 pF  330 Ohm

 

150 pF  330 Ohm

330 pF  2000 Ohm

150 pF  330 Ohm

330 pF  2000 Ohm

 

电压范围 接触放电(CD) 2 kV – 8 kV

空气放电(AD) 2 kV – 15 kV

 

接触放电(CD)2kV – 15 kV

空气放电(AD) 2kV – 25 kV

第一个峰值

Tr

 

0.6  – 1.0 ns 0.7  – 1.0 ns
第一个峰值误差率

Ip

3.75 A/kV

< ± 15 %

3.75 A/kV

< ± 10 % for 330 Ohm Res

0 ~+ 30 % for 2000 Ohm Res

 

40% RC处的电流值

I1

2 A/kV

< ± 30 %

2 A/kV, < ± 30 %

for 330 Ohm Res

 

0.275 A/kV, < ± 30 %

for 2000 Ohm Res

 

20% RC处的电流值

I2

1 A/kV

< ± 30 %

1 A/kV , < ± 30 %

for 330 Ohm Res

 

0.15 A/kV , < ± 50 %

for 2000 Ohm Res

 

所需设备 4 GHz带宽的ESD电流靶 –衰减器 –连接电缆

< ± 0.5 dB   DC – 1 GHz

< ± 1.2 dB   DC – 4 GHz

 

> 1.2 x 1.2  平米的参考地平面

 

示波器 > 2 GHz实时带宽

 

1 GHz带宽的ESD 电流靶 – 衰减器 – 连接电缆

< ± 0.5 dB   DC – 1 GHz

 

 

> 1.2 x 1.2平米的参考地平面

 

示波器  > 1 GHz 实时带宽

 

误差率 每个电压等级下,ESD电流波形需要重复测量5次。所有的波形都需要满足标准的规定。 每个电压等级下,ESD电流波形需要重复测量10次,10次的波形取Tr, Ip, I1, I2各参数的平均值。计算出的平均值需要满足标准的规定。

ESDEMC公司的ES613 ESD模拟发生器能够满足IEC61000-4-2(2008)和ISO10605(2008)标准的要求。ES613-20 放电电压达 ±20kV, ES613-30 放电电压达 ±30 kV。

ESDEMC公司的A4001 ESD 电流靶 能够满足IEC61000-4-2(2008)和ISO10605(2008)标准的要求 (达± 30 kV)。

ESDEMC公司的A4002 ESD 电流靶适配器 能够满足IEC61000-4-2(2008)和ISO10605(2008)标准,能够校准ESD电流靶和适配器的频率响应。

3. 测试装置:

ESD电流靶需要安装在一个60” x 60” (1.2 m x 1.2 m) 或者更大的垂直校准平板的中心位置。这个校准平板可以使法拉第笼的一个面。用8个螺丝和配套防松垫圈将电流靶固定在一个直径为40mm的孔洞上,孔洞位于校准平板的中心。示波器,衰减器,电缆位于屏蔽笼中,或者与ESD模拟发生器分置在校准平板的两侧。下图1为可采用的测试装置说明。

TN003_P01

图 1 ESD模拟发生器校准装置

衰减器直接连接ESD电流靶的输入端。如果电流靶的输出电压超过了示波器的输入电压范围,则还需要使用额外的衰减器。选择合适的衰减器,请参照下文中的衰减计算部分。将ESD地回路电缆与电流靶的参考校准平面相连。图2为简化的连接框图。

图2 ESD模拟发生器测量典型装置连接图
图2 ESD模拟发生器测量典型装置连接图

衰减计算

图3 ESD电流靶与20dB衰减器连接配置图
图3 ESD电流靶与20dB衰减器连接配置图

在上面的框图中,20dB的衰减器与阻抗设置为50 Ohm的示波器连接,用于测量ESD放电电流。因为接有20dB的衰减器,因此示波器的输入端电压V2为电流靶注入电压V1的1/10,或者说
V2= V1/10.
由于衰减器的终端阻抗为50 Ohm,所以端口1的输入阻抗为2.08//50 Ohm = 2.00 Ohm,意味着
V1 = IESD ×2.00 Ohm
其中,IESD是放电发生时,端口1的输入电流。2.08 Ohm的阻值是ESDEMC公司制造校准的A4001电流靶的标称值。其他生产商的电流靶阻值可能不同。ESD放电电流和示波器所测的电压之间的比率为
IESD / V2 = 5:1
这个比率对于确定衰减器衰减倍数,以确保示波器的测量安全是非常有用的。因为不同放电电压下的电流值是已知的。例如,当测试8kV静电放电电流时,IESD的峰值应该为30A,对应的示波器所测的电压峰值为6V。在任何新的测试之前,都应该增加衰减倍数以确保设备的安全,直到对测试装置有足够的信心再调整为合适的衰减器。
下表3提供了ESD源电压与推荐的电流靶衰减倍数的参考值。这是基于测量中所使用的示波器为50 Ohm 5V的实时示波器(测量范围为8V, 每格1V)。表中的绿色区域为安全工作范围,其中的数值为示波器所显示的电压峰值。黄色区域为需要避免的情况,因为测试标准中允许有±15%的峰值电流误差,因此衰减倍数可能不够。GHz级的高速示波器的最大电压读数为8V或者10V:

ESD源电压
(kV)
电流峰值
(Amp)
(Amp)
示波器显示的首个电压峰值
(Volt)
ESD电流靶与示波器之间的的衰减倍数
20 dB 26 dB 30 dB 40 dB
4 15 3.0 V 1.5 V
8 30 6.0 V 3.0 V
15 56.25 11.25 V 5.62 V 3.56 V 1.13 V
25 93.75 18.75 V 9.38 V 5.93 V 1.88 V
30 112.50 22.5 V 11.25 V 7.12 V 2.25 V

表3 ESD源电压与推荐衰减倍数

 

标准波形 (IEC标准)

+4kV放电电压下 IEC 61000-4-2 标准规定的电流峰值如下图4所示。

 

图4 IEC61000-4-2标准规定的ESD模拟发生器的理想电流波形
图4 IEC61000-4-2标准规定的ESD模拟发生器的理想电流波形

8kV IEC测量结果

 

图5 IEC61000-4-2标准ESD发生器放电电流波形
图5 IEC61000-4-2标准ESD发生器放电电流波形

 

测试级别 注入电压 峰值电流 (±15%)

Trise = 0.8 ± 0.2 ns

30 ns时电流值

(±30%)

60 ns时电流值

(±30%)

1 ±2kV 7.5 A 4 A 2 A
2 ±4kV 15 A 8 A 4 A
3 ±6kV 22.5A 12 A 6 A
4 ±8kV 30 A 16 A 8 A

表4 IEC 61000-4-2接触放电电流波形参数

 

 

电压 上升时间 (ns) 峰值电流 [A] 30 ns时电流值 [A] 60 ns时电流值 [A] 结论
IEC (±20%) Cal Result IEC (±15%) Cal Result IEC (±30%) Cal Result IEC (±30%) Cal Result  
2 kV  

 

0.8

(0.6~1.0)

0.905 7.5 (6.375~8.625) 7.6 4 (2.8~5.2) 3.45 2 (1.4~2.6) 1.75 符合标准
4 kV 0.909 15 (12.75~17.25) 15.15 8 (5.6~10.4) 7.6 4 (2.8~5.2) 3.3 符合标准
6 kV 0.914 22.5 (19.125~25.875) 22.3 12 (8.4~15.6) 11.3 6 (4.2~7.8) 5 符合标准
8 kV 0.925 30 (25.5~34.5) 30.6 16 (11.8~20.8) 15.5 8 (5.6~10.4) 6.5 符合标准

 

 

4. 常见问题

4.1 示波器的带宽/采样率对校准有什么影响?

一些ESD事件的上升时间<100 ps,有些实际的ESD波形可能上升沿的时间更短。示波器的带宽需要能够分辨大概0.35/rt ,或者说,100 ps的上升沿对应3.5GHz的带宽。没有足够的带宽或采样率,上升沿的数据采集是不准确的。下图呈现了没有足够采样率和有足够采样率的示波器所采集到的波形对比。

 

图6 示波器采样率对上升时间的影响比较
图6 示波器采样率对上升时间的影响比较

此外,示波器的带宽和采样率还影响测量到的第一个峰值大小,因为第一个峰值具有较高的频率分量。即使是同一示波器,当设置的采样率不同时,测得的结果也不同。这可能导致ESD模拟发生器在较低采样率的测试时能够通过标准,但实际上当采样率较高时不能符合标准要求。举例如下图所示。

图7 同一示波器不同采样率设置下的测量波形
图7 同一示波器不同采样率设置下的测量波形

 

4.2 当购买ESD电流靶时,是否可以只买电流靶,使用已有的电缆和衰减器做校准?

标准规定,在进行ESD模拟发生器的校准之前,示波器和ESD电流靶 – 衰减器 – 电缆都需进行校准。如果电流靶的校准没有配备相应的衰减器和电缆,当使用新的衰减器和电缆时,电流靶需要进行再校准。或者使用人员可以表征其已有的电缆和衰减器,然后从数值上进行补偿计算。
标准规定,校准所用的电缆应该为屏蔽良好,损耗低的电缆。标准推荐采用不超过1 m 长的RG400电缆。RG214电缆的损耗为RG400的1/2,通常情况是可用的,但可能不匹配SMA接头。大多数高速示波器采用了SMA或者改良的BNC接头。
标准规定,衰减器需要有4GHz内平坦的频率响应,以保证电流靶 – 衰减器 – 电缆的传输阻抗平坦。同时,衰减器需要能够承受相对较大的峰值功率。

4.3 其他参数对测试波形有什么影响?

表5 其他参数的影响

参数 影响
屏蔽 1.2 m x 1.2 m 的参考平板可以用于屏蔽ESD模拟发生器和示波器时间的直接耦合。这是标准中所规定的。不同的示波器所观测到的结果可能有很大不同。一些示波器会观测到很严重的噪声耦合(不接ESD电流靶),而一些示波器观测到的噪声耦合很小。
接地电缆位置

 

地线的长度和形状影响着地环路的感抗,因此对第二个RC峰值有影响。正确放置的接地电缆对测量结果的影响很小
ESD模拟发生器的方向

 

通常来讲对测试波形有一定影响,但影响很小
空气放电

 

接近速度和环境参数对结果的可重复性影响很大
Posted on

PB2016.02 PV模块二极管的ESD失效分析及TLP测试方法

下载 PDF – PV模块二极管的ESD失效分析及TLP测试方法

安装在太阳能电池阵列中的旁路和阻塞二极管是太阳能电池系统功率的重要保证。然而,这些二极管对于潜在的静电放电(ESD)时间非常敏感。这些静电放电时间可能发生在太阳能光电池(PV)阵列的生产,运输,和现场安装过程中。PV模块质量保证国际论坛 [1] 的设立是为了研究PV模块的稳定性,其中的第4工作小组负责研究测试用于PV阵列二极管的ESD鲁棒性,以及如何提高PV阵列性能。

本文阐述了二极管ESD失效背后的原理,介绍测试和分析二极管的有效方法。 文中给出了太阳能阵列制造商所提供的几种型号二极管的测试方法和结果,以说明该测试方法的有效性。

[slideshare id=60840504&doc=esdemcpb2016-160413032603&type=d] 更多阅读: http://incompliancemag.com/article/esd-failure-analysis-of-pv-module-diodes-and-tlp-test-methods/#ixzz45fk4HnPT

Posted on

PB2015.12 瞬态静电放电模拟器的系统级模型

 下载 PDF – 瞬态静电放电模拟器的系统级模型 摘要— 论文介绍了一种改进的静电放电系统级瞬态模型,通过比较模型和IEC 61000-4-2 静电枪对实际产品放电的测试结果,讨论验证了该模型的正确性。该系统模型为大电流宽带(至3 GHz)模型,由电阻,电感,电容,铁氧体磁珠,二极管和集成电路IO管脚构成。复杂回流路径的模拟是实现系统在IEC激励下有正确响应的关键点。模型还包含了有能量限制的时间依赖的IC损伤模型。论文引入了功率-时间积分方法,用于准确判断当注入一个任意波形时,结点是否会发生热失效 。该方法不需要知道结点的微观结构,材料信息,缺陷位置,或熔融温度。 索引 — 共模,电磁兼容 (EMC), 静电放电 (ESD), 人体金属模型 (HMM), IEC 61000-4-2, 系统有效ESD 设计(SEED), 传输线脉冲 (TLP).
Posted on

PB2015.11 滚动转移过程中显示面板摩擦充电的多物理模拟

下载PDF – 滚动转移过程中显示面板摩擦充电的多物理模拟

MULTI-PHYSICS SIMULATIONS FOR TRIBOELECTRIC CHARGING OF DISPLAY PANELS DURING THE ROLLER TRANSFER PROCESS

50 Words Abstract – A multi-physics simulation methodology for triboelectric charging during the roller transfer process of display panels is proposed. Electrical and mechanical models for triboelectric charging are developed. Comparisons between the measured and the simulated results are conducted for the transient triboelectric charges of the display panels.

I. Introduction

There are several contact and separation steps during the display manufacturing process which increase productivity and automate manufacturing processes, such as the roller transfer of display panels and lift-up of display panels from vacuum stages. However, the glass for display panels is an insulating material in contrast to the dissipative silicon substrates; therefore, it is hard to bleed off the accumulated trioboelectric charges that accumulate.

Triboelectric charging is a physical phenomenon that has been known for thousands of years. Principles of triboelectric charging are applied in laser printing toners, electrophotography, energy harvesting devices, material separations, textile processing, pharmaceuticals, and granular flow processing. However, mechanisms of triboelectric charging are not completely understood [1]. Theoretical modeling and experimental work was conducted to address triboelectric charging of display panels [2, 3]. However, based on the authors’ survey there are few simulation approaches for the analysis of triboelectric charging of display panels.

In this work, a multi-physics simulation methodology for triboelectric charging of display panels during the roller transfer process is proposed. The electrical and mechanical modeling of the roller transfer process is included, and simulation results for the transient triboelectric charges and the E-field distributions on the display panel are shown.

II. Simulation Framework for Triboelectric Charging of Display Panels During Roller Transfer

Triboelectric charging of display panels during the roller transfer process is a multi-physics problem, i.e., the accumulated charges on display glass are dependent not only on the electrical properties of materials such as (effective) work functions, surface states and contact capacitances, but also on the mechanical properties such as friction, contact pressure and area between the glass and the rollers. In addition, the problem is not a static, but a timedependent event. Typical properties of triboelectric charging of display panels during the roller transfer process and related physics and simulation parameters are summarized in Table 1 based on previously published experimental works [1-4].

Although several simulation tools for multi-physics problems are commercially available such as COMSOL, there are few well-defined simulation models for triboelectric charging of display panels and the physical mechanisms are not clearly defined yet. It would be good to verify the proposed simulation methodology first and then implement it into the commercial multi-physics software by adopting the analytical modeling approaches.

Fig. 1 shows the flow chart of the proposed simulation methodology for triboelectric charging of display panels during the roller transfer process. First, the electrical and the mechanical properties of the glass and the rollers such as (effective) work functions, empirical parameters for triboelectric charging, dimensions and velocities of the roller transfer system, Young’s moduli and passion ratios, and so on are required to calculate the number of contacts, the contact area between the glass and the rollers, and the triboelectric charges at a given time. The triboelectric charges consist of contact and separation and frictional charges which are explained in this section. The variations of the roller diameters due to manufacturing tolerances and wear out are not considered in this work. The electrical and mechanical calculations are repeated until the charge calculation time is equal to the given E-field calculation time. After finishing the calculation of the charge distribution on the bottom of the display panel, the Efield distribution is calculated using a 3D electrostatic field simulator.

A. Modeling for Triboelectric Charging of Display panels

1. Modeling of Electrical Properties

Although the phenomenon of triboelectric charging has been described even in ancient times, there are few well-defined physical models for triboelectric charging between insulating materials. Triboelectric charging between metals or metal-to-insulator materials are well explained using the concept of work functions or effective work functions; however, many different charging mechanisms have been proposed such as electron transfer, ion transfer, and material transfer in order to physically explain triboelectric charging between insulating materials [1].

In this work, empirical modeling approaches [1, 4] are adopted to model the triboelectric charging: the empirical model consists of the charge transfer and the discharge terms, and requires experimental data to fit its coefficients. The driving force for the charge transfer is the difference in surface voltage between two materials and charges on the materials. The equation for net charge transfer is derived as [1]

where n is the number of contacts; qc and ql are the generated and the leakage charges of the triboelectric charging process, respectively; Cc is the contact capacitance between two materials; Vc is the (effective) work function difference; f is the frequency of the triboelectric charging process; and kc, ki, and kl are proportional constants for the generated, the leakage, and the image charges, respectively. Solving (1) with the initial condition q=q0 when n=0, gives the following equation,

which is used to calculate the triboelectric charges between the glass and the rollers, where n0 is the characteristic number of the triboelectric charging, q0 is the initial charges on the glass, and q∞ is the saturated charges on the glass. Both the characteristic number of triboelectric charging and the saturated charges are functions of the capacitance between two materials, the contact area, the frequency of the triboelectric charging process, and the (effective) work function differences as shown in (3) and (4)

It is important to note that the proportional constants kc, ki, and kl are empirical parameters and the contact area between two materials should be known in order to calculate the capacitance between them.

Equations (1)–(4) were originally developed to describe the electrification by impact of a sphere on a plane, and Fig. 2 shows the conceptual analogy between the electrification by the impact of the sphere and by the roller transfer process. The (n-1)th, n th, and (n+1)th rollers simultaneously contact the display panel and shift left with the frequency of vtrans/d, where d is the spacing between the shafts, and vtran is the transfer velocity of the glass. The contact frequency of a specific location on the glass from the n th to (n+1)th rollers is equal to vtrans/d.

The E-field distribution on the display panel is calculated by numerically solving the 3D Poisson’s equation with the boundary conditions of the charge distribution on the bottom of the display panel and the grounding conditions of the shafts. A commercially available 3D solver, CST EM Studio, was used in this work. It was assumed that the charges do not move on the surface via surface discharges.

2. Modeling of Mechanical Properties

The transmission of the glass on the roller transfer system is based on the rolling contact between the rollers and the glass. In the rolling contact, the contact area is divided into two domains: a sticking domain with the length of 2a′ and a slipping/skidding domain with the length (2a-2a′). In the sticking domain, the relative velocity at the contact vtran-Rω is zero, which means the pure rolling condition (static friction). In the slipping/skidding domain, the relative velocity is a nonzero value, which means the slipping condition (dynamic friction). In other words,

where 2a is the contact length of two cylinders with parallel axes from the Hertzian equation, τ(x,t) is the tangential stress distribution, p(x,t) is the Hertzian pressure distribution, μ is the friction coefficient according to the friction law of Coulomb, ω is the angular velocity, and R is the radius of the rollers [5, 6].

The ratio of each domain in the contact area depends on the relative velocity at the contact, and the areas of each domain are calculated using (7) and (8)

where Fn is the applied load, R′ is the combined radius, E′ is the combined elasticity modulus, and wroller is the width of the rollers [5, 6]. The number of rollers beneath the glass is calculated every time, and then the force due to gravity is divided by the number of rollers to calculate Fn. Under pure rolling, i.e., the rolling without slipping condition (vtran=Rω), the area of the sticking domain is equal to the Hertzian contact area, while the area of the slipping/skidding domain grows with increasing the relative velocity at the contact until it encompasses the entire contact area.

Because the skidding/slipping may stain the surface of the glass and cause display failures, the translational (transfer) and circumferential velocity should be under control in order to minimize the skidding/slipping during the display manufacturing process. However, the relative velocity at the contact inevitably increases/decreases during either acceleration (vtran<rω) or=”” deceleration=”” (vtran=””>Rω) of the transfer velocity at both the beginning and the end of the roller transfer system, or during transfer velocity changes between two manufacturing units. Fig. 3 shows the conceptual diagram for the relative velocity at the contact and the corresponding contact areas of the sticking and the slipping/skidding domains during the roller transfer process of the display panels.</rω)>

Triboelectric charges tend to increase as the acceleration/deceleration time of the transfer velocity decreases, or when there is a transfer velocity difference between manufacturing units as shown in Table 1 [2, 3]. There are still arguments on the physical causes of the increased charges, and potential reasons are increased contact area for charge transfer, localized frictional heating, material transfer, and so on [7–9]. In [9], the authors experimentally showed the effects of the contact area and the relative velocity at the contact on the triboelectric charges by changing the normal contact force and the rubbing velocity between two materials, respectively. In addition, the heat produced through friction is proportional to the contact area and the relative velocity at contact as shown in (9) [10]

Based on the previously mentioned works, (2) is modified in order to consider the different triboelectric charging characteristics of the sticking and the slipping/skidding domains of the contact area as shown in (10)

where qsticking is the triboelectric charges between the glass and the rollers under the pure sticking condition, and qslipping/skidding is the triboelectric charges between the glass and the rollers under the pure slipping/skidding condition. Pure contact and separation electrification for the sticking domain, and pure frictional electrification for the slipping/skidding domain are assumed. The triboelectric charges for the partial sticking and partial slipping/skidding conditions are calculated by summing the multiplications of the triboelectric charges of the pure sticking and the pure slipping/skidding conditions by the areas of each domain, as shown in (10).

3. Modeling of Triboelectric Charging Characteristics Between Glass and Roller

In order to simulate triboelectric charging using (10), six constants n0, q0, and q∞ values for the pure sticking and the pure slipping/skidding conditions should be experimentally determined by fitting with the measured triboelectric charges because they are functions of not only the known physical constants (such as the (effective) work functions, the contact capacitance, the effective contact area and frequency), but also the empirical fitting parameters (kc, ki, and kl for the charging and the discharging efficiencies, humidity, surface roughness, manufacturing tolerance, and so on), as shown in (3)–(4).

An apparatus for determining the triboelectric charging between the glass and the rollers was developed in our research group. Material characterizations for the triboelectric simulations and correlation results between the measured and the simulated results are shown in section III. In this section, the triboelectric charging characteristics are fitted based on data in the published paper for insulating and dissipative materials [11].

Fig. 4 shows the modeled triboelectric charging characteristics between the glass and a single roller as the function of the number of the contacts for the purpose of simulation tool development. For the sample selected it was observed that the accumulated charges with the dissipative material were larger than those with the insulating material, and the charging time was also faster with the dissipative material [11]. The authors experimentally show that static dissipative surfaces can charge up insulating surfaces more efficiently than actual insulating surfaces in the case of friction between grounded static dissipative and insulating surfaces, and emphasize that triboelectric charging is highly related to the test arrangement and insulators must be evaluated case by case.

We analyzed the triboelectric charging behavior of the display panels during roller transfer processing by using the aforementioned electrical and mechanical models and the modeled triboelectric charging characteristics. In order to obtain the best possible prediction of the quantity of the triboelectric charges, fitting of the empirical parameters should be conducted with the same materials of the roller transfer system, which is discussed in section III in detail.

B. Simulated Triboelectric Charging of Display Panels

1. Charge Distribution Beneath Display Panel

Fig. 5 shows the schematic diagram of the roller transfer system of the display panels, where sshaft and sroller are the spacing between the shafts and the rollers, respectively, and ldisplay and wdisplay are the length and the width of the display panel, respectively. The values of wroller, ldisplay, and wdisplay are 10, 2200, and 1870, all in mm, respectively. Two different combinations for the values of droller and sshaft are used; 60 and 150 (case 1), and 180 and 450 (case 2), all in mm, respectively. The transferred distance, dtransfer, is determined by the transfer velocity and the E-field calculation time.

Fig. 6 (a) shows the transient triboelectric charges on the bottom of the display panel at 5 and 15 sec with a 100 mm/sec transfer velocity, and rollers are assumed to be made of dissipative material. Fig. 6 (b) shows the transient triboelectric charges on the bottom of the display panel with the same condition, but now assuming insulating rollers. In both of cases, the diameter of the rollers and the spacing between the shafts is 60 mm and 150 mm, respectively. The maximum values of the triboelectric charge density with the dissipative and the insulating rollers at 15 sec are 10.5 nC/mm2 and 3.8 nC/mm2 , respectively. The triboelectric charges with the dissipative rollers reach the saturation value of triboelectric charging faster than those with the insulating rollers.

2. E-field Distribution on Display Panel

Fig. 7 (a) and (b) show potential distributions on bare glass at 15 sec using a transfer velocity of 100 mm/sec. The insulating materials for the combination of case 1 and 2 are used. Three lines of rollers are considered.

The peak potential of case 2 is 1.7 times higher than that of case 1 because the increased distance from the ground which is linearly proportional to the diameter of the rollers. Both of the cases are simulated under rolling condition without considering slipping.

III. Material Characterizations and Correlation between Measured and Simulated Results

A. Descriptions of Characterizations and Measurements Setup

Fig. 8 shows the fabricated apparatus for the characterizations of the roller and the glass materials and the measurements of the triboelectric charges of the roller transfer process, where the width and the transfer length of the apparatus are 61 cm and 188 cm, respectively. The stepper motors are used to control the rotational speed of the rollers and to control the height of the lift pins. The glass travels back and forth on the rollers by changing the rotational direction of the rollers, and the acceleration/deceleration time of the transfer velocity is also controllable. The lift pins are used to investigate the effect of the height of the glass from the ground on the electrostatic voltages on the glass and for charge creation during lift off from a metallic platform.

Several design parameters such as the diameter of the rollers, the spacing between the rollers, and the spacing between the shafts are mechanically adjustable. Insulating UHMW (ultra-high-molecularweight) polyethylene was used to fabricate the rollers. Alkaline earth boro-aluminosilicate glasses are used for the characterizations of the materials and the measurements of the triboelectric charging.

The triboelectric charges were measured using a Faraday cup and the ES103 solid state electrometer from ESDEMC Technology LLC. The TREK model 347 electrostatic voltmeter was used to measure a voltage that leads to a field cancellation on the glass and the rollers [12]. In order to control the ambient humidity and temperature all of the characterizations and the measurements were conducted in the climate chamber with 30% humidity and 22° C ambient temperature [13]. In this work the 30% R.H. was selected, which is the lowest reliable level of humidity at 22° C which can be achieved in the climate chamber in summer months. Follow up experiments in the winter will allow lower humidity. The rollers and the glasses are cleaned using 91% isopropyl alcohol and preconditioned in the climate chamber for a minimum of twelve hours.

Firstly, the material characterizations were conducted by changing the number of the contacts, and based on the characterization results the required simulation parameters were extracted. As the next step, the multiphysics simulation of the triboelectric charging was conducted with different operating conditions and compared to measurements.

B. Characterization of Materials

In this work, the triboelectric charging characteristics under rolling without the slipping condition were studied. Because the triboelectric charges are dependent on the relative velocity at the contact and there are velocity changes due to the acceleration and the deceleration periods at both ends of the roller transfer system, two-step measurements were conducted in order to extract the triboelectric charges of the sticking domain only. The proposed method can also be applied to the triboelectric charging characterizations for the rolling with slipping condition, which is a future work.

First, the glass on the roller transfer system travelled back and forth with only the acceleration and the deceleration periods as shown in Fig. 9 (a), and the triboelectric charges on the glass were measured using the Faraday cup and the solid state electrometer. The triboelectric charges were measured again within the constant velocity period, as well as during the acceleration and the deceleration periods as shown in Fig. 9 (b). Using these two measured triboelectric charges, the triboelectric charges under the rolling without slipping condition were de-embedded.

The de-embedding was conducted by subtracting the triboelectric charges during the acceleration and deceleration periods from those having completed full periods. The driving conditions of the roller transfer system are summarized in Table 2.

Fig. 10 shows the measured triboelectric charge densities on the glass as the function of the number of contacts: the solid blue circles show the charge density with the driving conditions of the acceleration and the deceleration periods only, and the solid black triangles show the charge density with the driving conditions of the acceleration, the constant velocity, and the deceleration periods. The solid red squares show the de-embedded triboelectric charge density based only on the steady-state transfer velocity period. With less than 2400 number of contacts the measured triboelectric charges due to the acceleration and the deceleration periods are higher than those due to the steady-state transfer velocity period, however, the triboelectric charges due to the acceleration and the deceleration periods reached the saturated values of the triboelectric charging faster than the triboelectric charges due to the steady-state transfer velocity period.

The empirical parameters are extracted using the measured triboelectric charges. The purple line shows the simulated triboelectric charge density due to the steady-state transfer velocity period, and they show good agreements with the measured the triboelectric charge density due to the steady-state transfer velocity period.

C. Comparisons Between Measured and Simulated Results

Triboelectric charges due to the steady-state transfer velocity period were simulated with the extracted simulation parameters by changing the transferred distance. Fig. 11 shows the measured and the simulated total charges on the glass, where the solid red squares show the measured total charges and the purple line shows the simulated total charges, which show good agreement with the measured charges.

IV. Conclusions and Future Works

A simulation methodology for triboelectric charging of the roller transfer process is proposed. First, the methodology was verified based on previously published triboelectric characteristics of materials. The apparatus for the triboelectric charging characterizations of the glass and roller materials was developed, and material characterizations were conducted. Based on the material characterization results, the empirical parameters in the triboelectric charging equations were extracted and comparisons between the measured and the simulated triboelectric charges were conducted.

The developed simulation methodology is based on empirical equations. Systematic characterizations for triboelectric charging of glass on the roller transfer system using the developed apparatus would greatly helpful to optimize the empirical parameters extraction process and the equations themselves. In addition, the verification of the proposed triboelectric charging equations for the slipping/skidding domain is another future work.

Acknowledgements

The authors would like to acknowledge Samsung Display Co., Ltd., for supporting this project. The authors also would like to thank Jeffrey Birt for the design and fabrication of the roller transfer system and thank ESDEMC Technology LLC for providing the solid state electrometer.

Posted on

TR001 管脚限制器二极管的VF-TLP特性

3D Diode TransientResistance-Time-Voltage Surface Plot

下载或查看pdf: TR001 管脚限制器二极管的VF-TLP特性

目标是测试引脚限制器二极管的ESD特性。这些二极管的最终用途由诸如导通电压、动态电阻、二极管电容和生存电流等参数决定。基于这些参数二极管可以被选择适用于实验室设备的ESD保护应用。

引脚限制器二极管是从诸如Cobham、Skyworks、Microsemi和Avago等不同生产厂商购买的。这些二极管被焊接在评估PCB的从布线到地的反向偏置方向。他们会先按照他们的频率测试再使用VF-TLP设置测试ESD特性。这些二极管的测量结果在报告的后面部分展示。

作者Shubhankar Marathe、Jerry Tichenor、David Pommrenke、黄为

Posted on

PB2015.09 显示屏上的无火花静电放电ESD

下载PDF – 显示屏上的无火花静电放电ESD

SPARK-LESS ELECTROSTATIC DISCHARGE ESD ON DISPLAY SCREENS

Abstract—An electrostatic discharge (ESD) to a display screen may lead to sparking into the phone’s structure, e.g., via the glue that connects the different glass layers of the touching panel/LCD, or it may just cause surface charging. The latter is the most likely case for a well-designed display, as the insulation design usually prevents any sparking to the electronics. Even if no spark is visible, strong surface charging occurs. These charges couple via displacement current and via their magnetic field into the display electronics. Most phone and tablet manufacturers currently suffer from damages or upsets caused by this type of spark-less ESD. As far as we know, no data has been published showing the magnitude, rise time and total charge parameters of these surface discharges for displays. In this paper, discharges to different displays have been measured at ±4, ±8, ±10 and ±14 kV. The discharge currents are measured using an F65 current clamp. Five different types of display screens have been tested and the results of transient current discharges are compared in this paper. During the experiments, repeatability of results is investigated. Moreover, the effects of touch position as well as dirty screens (i.e., presence of finger prints, etc) are investigated.

Keywords— Electrostatic discharge (ESD), portable device, display screen, rise time;

关键词:静电放电(ESD)、便携设备、显示屏、上升时间

I. INTRODUCTION

Electrostatic discharge (ESD) is a severe source of interference in electronic products and can produce damage or upset failures. In different areas, ESD has been studied. In [1], decay times of ESD events caused by garment removal and sitting/standing motions from a chair are presented. In [1]-[6]. ESD in data centers caused by various types of human activities—walking, sitting/standing from a chair, and garment removal—have been studied at different dew points (various temperature-relative humidity). Presently, many manufacturers of portable electronic devices which utilize display screens including mobile cell phones, smart phones, multimedia players, etc., are facing severe ESD related problems which demands ESD protection, [7]-[10]. In most of these products, LCD, LED, or electronic ink screens are utilized. Generally, ESD on electronic products might occur when the device itself becomes charged by triboelectrification and approaches another conducting object. Other types of ESD occur when a human, charged by triboelectrification, touches the electronic product. Thus, it can be said that the ESD can either produce a spark (e.g., to the body of the cell phone), or it can be a sparkless corona charging the glass display screen. Therefore, there is high interest in the understanding of ESD events on the display screens of portable electronic products.

This paper presents measurements of spark-less discharges to displays. The ultimate goal of this work is to understand the mechanisms that allow the spark-less discharges to upset or destroy display or touch screen circuits. A prerequisite to this is to understand the current magnitudes, rise times, and total charges associated with an ESD event and their dependence to parameters like polarity, voltage, and different display types. Further, quantifying the current densities through display glass and the current density distribution is important. This paper reports on measurement and analysis of the governing parameters for spark-less surface discharges to displays. The distribution of the deposited charges can be further illustrated using the Lichtenberg dust figure method [11]-[14], which is known that related to the discharge voltage level, polarity, etc.

II. MEASUREMENT SET-UP

Fig. 1(a) shows the measurement set-up. An ESD gun or generator connected to voltage source is used to create the desired discharges to the device under test. A current clamp, F65 (Fischer Custom Communications), having a transfer impedance of 1 ohm, is used to measure the discharge current. Five different displays are compared, including displays released in 2014. In the real application the displays are connected to the main PCB of the device by flex cables. These nets have ESD protection, so it is reasonable to assume that these nets act as if they are connected to the system ground. For the displays which are tested without being integrated into a functional system, the flex cable connectors are grounded. Furthermore, the displays usually back against a metallic frame of a cell phone, tablet, etc. These frames are connected to a large ground plane. Electrically, the consequence is that part of the displacement current that flows through the glass can flow via the touch and LCD flex cable to ground, and part will reach the back metal structure. As of now, the ratio of currents is not known, but the touch circuit’s ITO layers have a high resistance, such that the current fraction through these layers maybe small. The ESD generator is grounded to the metal plane, which is also connected to the oscilloscope shield. A current clamp, shown in Fig. 1(b) is placed around the air discharge ESD generator tip. A coaxial cable via a bulk-head SMA connector is connected to the current clamp to divert any common mode current away from the oscilloscope. As further protection, a 20dB attenuator is used. The experiment is conducted by approaching the display with the ESD generator (in air discharge mode). As seen in Fig. 1(c), five display screens are utilized for experiments, and are labeled as screen #1 to #5. To perform the experiments, charge voltages of ±4, ±8, ±10, and ±14 kV were used. The surface of the screens can be clean or dirty. The touch location and approach speed were varied. Three approximate approach speeds were used, and are referred to as “slow”, “medium”, and “fast”. The slow approach speed was in the range 1cm/sec, and the fast approach was close to the speed which may break the glass. Thus, the medium approaching speed was used in most experiments. As shown in Fig. 2 for voltage of +8 kV, the influence is strong and the slow approach has the lowest discharge current and the fast approach has the highest current. While achieving constant speed was difficult, each experiment was repeated several times for each experiment. Further, a phenomenon observed from discharge current is a double peak, shown in Fig. 3 for screen #1 to #3, at +8 kV. It shows that the 1 st rise time is faster than the 2nd .

III. MEASUREMENT RESULTS AND DISCUSSIONS

A. Repeatability

To understand the natural and experimentally induced variations of these discharges, repeatability testing was performed. Each discharge measurement was repeated at least 3 times using medium approach speed to the center of the screen. Tests were repeated over three days. The results are presented in Fig. 4. From the results, variation of the peak current are seen which might be due to variation of approaching speed (i.e., faster approaching often gives higher current, and faster rise time), humidity and temperature [1], fine layer of moisture, spark initiation, etc. Comparing all the screens together shows that screen #1 experiences the highest peak currents and screen #2 has the lowest peak currents. Generally, these currents show a fast rise (< 2 nSec) and a slower decay. The decay to 50% of its amplitude is about 20- 30 nSec. The amplitudes are highly voltage dependent but reach a few amperes for +10 kV, which explains their potential to disrupt or damage displays. This is true for human metal discharges (IEC 61000-4-2 or also called HMM). A discharge from the skin (Human Body Model–HBM) shows much lower currents. Thus, this paper provides data related to ESD tests in which a metal part is used to touch the screen. The current rise times and peak values determine the current derivative which quantifies the magnetic fields which may induce voltages in the screen electronics. Thus, two mechanisms may lead to disturbances: the current derivative induced voltages, and the displacement currents. The total charge, peak current, and 1st and 2nd rise time parameters are presented for +4kV in Table I. The numbers show the average of results for different days. Both mean value (m) and standard deviation (s) are presented to illustrate the repeatability. For reasons presently unknown, but suspected to be related to the glass thickness and grounding of the touch and LCD structure, it is observed that screen #1 has the largest average peak current (0.7 Amp, +4 kV) and screen #2 has the lowest average peak current (0.31 Amp). This again indicates that the design of screen #1 may contain features that will create more difficulties in passing IEC 61000- 4-2 tests. The average peak current from all the screens is around 0.45 Amp. Also, screen #2 showed the lowest peak current but the largest transferred charge (7.67 nC) on its surface. As there is no conduction current flowing through the glass, these charges are deposited on the glass surface. Also, the lowest transferred charge (3.6 nC) was measured on screen #4. The average charge transfer at +4 kV was around 6.3 nC. The first peak showed an average rise time of 0.49 nSec. This value may already be influenced by the 1 GHz bandwidth of the current probe. The second peak current rose in 1.35 nSec (screen #4). The slowest rise of 0.48 nSec was observed on screen #2. The average rise time for the second peak was 2.49 nSec.

B. Dirty vs. Clean Screen

The presence of fingerprints (i.e., a more realistic case than a clean screen) causes a thin layer of oil, dust, etc. which can lead to changes in the amount of current or transferred charge on the screen. Thus, it is interesting to analyze the discharge behavior for the case of dirty screens and compare them with clean ones. To do this, three screens were selected: screen #1, #4, and #5. The ESD source voltage level was set on +4 kV. The discharge measurements were repeated three times at medium speed at the center point of the screens. As seen in Fig. 5, the presence of fingerprints or dust on the display screen has little effect on the discharge behavior. A double rise is observed again for all cases. The results are combined together in Table II. As seen, the mean values of the peak current amplitude for a clean (0.97 Amp) and a dirty (1.04 Amp) screen for screen #1 are similar. However, around 0.1 Amp difference is observed for screen #4 and #5. Moreover, dirty screens showed a higher transferred charge (about 1nC higher). The first and second rise times remain about the same.

C. Position

If a large portion of the current would flow via the ITO layers of the touch-screen or the LCD structures, then a discharge position towards the interfaces would have a lower resistance path, and would lead to a higher current. As seen in Fig. 6, three different positions including top, center, and bottom were tested at different times. No large variation was observed when testing three screens (screen #2, #4 and #5) at +4 kV using a medium approach speed and clean surface. This indicates that a large portion of the current might flow as displacement current through the display to the metallic backing structure.

D. Polarity and voltage level

The dielectric response of the glass, and the conductivity of metal structures is linear with respect to voltage and polarity. While ESD protection structures usually are not symmetrical, it is unlikely that this asymmetry can be seen in the current of the spark-less discharge, as all ESD protection of the touch and LCD probably turn on, resulting into a virtual short. However, it is known that surface discharges may strongly depend on the polarity due to the large difference in the velocity of electrons, relative to ions. This motivated us to compare the currents for both polarities. Strong difference may indicate a higher likelihood of failures in one polarity.

Here, a medium approach speed and a discharge location in the center of a clean screen were selected. Each experiment was repeated 3 times for all the voltages. Fig. 7 presents the current waveforms for positive charge voltages (A to D), and for negative charge voltages (E to H). The peak current dependency as well as charge for positive/negative voltages is shown in Fig. 8 (H to J).

There are strong differences between negative and positive charge voltages. While the rise times are similar, the peak current for negative charge voltages is more than 10 times smaller than positive charge voltages (compare Fig. 7: A to E, B to F, C to G, D to H).

In addition, the peak current increased, reaching 4 Amp for voltages up to +10kV for the positive case (Fig. 8, I), however, within the limited range of our present observations from -4 to -14kV, the largest peak current was measured at -4kV, while -8 to -14kV showed the same peak currents (Fig. 8, K).

Moreover, the distributed charges are much larger for the positive case. The charges increased to about 70 nC (+10 kV, Fig. 8, J). The negative voltages led to charges up to -6 nC (Fig. 8, L).

In all but the very slow approach speed case, positive charge voltages let to a double peak in the rising edge, this was rarely observed for the negative voltage.

Beside, screen #1 showed the highest peak currents (Fig. 7, A to D). The design details of the screen are not known, however it indicates that this design maybe more ESD susceptible due to the higher currents.

Multiple possible consequences can be supported from the results. If the failure mechanism is polarity independent and related to rise time, no polarity dependence would be expected. However if the total transferred charge is relevant (e.g., melting of a trace), or the peak current is critical, then the robustness will be less for positive polarity discharges. To analyze these results with respect to the current density of the displacement current that leads to currents on the ITO layers and in the LCD, an additional fact needs to be considered. It is known that the charge distributes over a much smaller area for negatively charged electrodes. Although the peak current is less for the negative charge voltage, it might be stronger concentrated in one area. On the other hand, if the peak current correlates to the failure mechanism, then positive polarity is worse than negative polarity for failure level. Also if the total transferred charge matters (e.g., a trace burns out), then positive polarity should be worse than negative polarity.

IV. CONCLUSION

In this paper, measurement results from spark-less electrostatic discharge on five display screens are presented. Using an ESD generator in air discharge mode, the currents are measured at ±4, ±8, ±10 and ±14 kV using a current clamp. The surface discharge waveform shows a fast double peak rise +14kV, a charge transfer of about 60 nC and a peak current of 5 Amp was measured. These currents are sufficient to damage or disrupt the display. These peak currents depend non-linearly on the voltage and may not even increase with increased voltage. This research will be continued by modeling the current distribution in the display between the touch and LCD connections relative to the displacement current that flows through display to the metallic body of the grounded system.

ACKNOWLEDGMENT

This material is based upon work supported partially by the National Science Foundation under Grant No. IIP-1440110 and the work is supported in part by the scholarship from China Scholarship Council (CSC).x

Posted on

PB2015.08 TVS二极管标称参数与静电放电防护能力研究

下载PDF – TVS二极管标称参数与静电放电防护能力研究

摘要:通过搭建ESD测试系统,测量TVS二极管的ESD防护性能,比较其标称参数与ESD防护性能之间的关系。结果表明,TVS二极管的反向击穿电压在一定程度上能够反映ESD防护能力,反向击穿电压与ESD峰值电流、ESD钳位电压呈线性关系,标称钳位电压略低于实际ESD钳位电压,而其他标称参数与ESD防护能力关联较小。标称参数难以全面反映器件的ESD防护能力。

关键词:瞬变电压抑制二极管;标称参数;静电放电测试方法;静电放电防护能力

目前集成化、多功能化的电子产品应用广泛,而且产品的工艺尺寸不断缩小,这使得静电放电(ESD)问题日益严峻[1-2]。静电危害会导致产品故 障或性能下降,降低使用寿命。如何提高产品的静 电放电防护能力受到学者们的广泛关注,使用ESD防护器件是有效的解决方案之一[3]。但目前没有统一的标准来评估静电防护器件的防护性能,这给ESD防护器件的选择和ESD防护设计带来了诸多 的不利。本文以常用的防护器件瞬变电压抑制二极管为对象,研究其标称参数与ESD防护性能的相关性。

1TVS二极管简介

TVS即瞬变电压抑制二极管(Transientvolt-agesuppressordiode),是一种常用的静电防护器 件[4-5],将其并联到保护结构两端,能够及时泄放瞬态大电流,实现电路防护。

1.1TVS二极管的工作原理

TVS是一种半导体二极管,内部是由硅通过扩散工艺形成的PN结[6-7]。TVS用作静电防护时,内部PN结处于反向偏置状态。在一定电压范围内,PN结截止,仅有很小的漏电流流过,TVS表现为高阻抗状态。当反向电压高于PN结反向击穿电压时,由于PN结的内电场很强,少数载流子受到强电场作用,获得很大的能量,并与其他原子发生碰撞,形成新的电子、空穴对,增加了载流子数量,新的载流子又会在强电场作用下碰撞形成更多的电子、空穴对,造成连锁反应,使反向电流迅速增大,此时TVS表现为低阻抗状态,并吸收大量脉冲功率,使两极间电压钳位在一个预定值。利用TVS的雪崩击穿特性,可实现ESD防护[8]。

1.2TVS二极管的标称参数

TVS的数据手册中给出了一系列标参 数。一个双向TVS的典型参数如图1所示。其中,IT是测试电流,常为1mA;VBR是测试电流条件下的击穿电压,即内部PN结雪崩击穿电压值;VRWM是反向工作峰值电压,略小于击穿电压;IR是器件端电压为VRWM时的最大反向漏电流;IPP是规定脉冲条件下(10/1000μs标准指数波形)最大反向峰值电流;VC是反向电流达到峰值IPP时的钳位电压。手册中还列出标称功率值,为在测试波形下的峰值消散功率PPK=IPP·VC。

上述TVS的典型参数在一定程度上能表征其工作特性,但并不能全面地反映TVS器件对静电放电的响应。

 静电放电实验研究

2.1ESD防护参数

衡量保护器件抗静电放电能力的参数主要有:器件鲁棒性、静态工作参数、动态保护工作参数。器件鲁棒性指器件自身对静电放电的耐受能力,健壮的鲁棒性能保证器件正常工作而不受损伤。静态工 作参数的意义在于受保护结构或系统正常工作时,保护器件不会降低系统工作性能,尤其是保证输入输出信号的完整性,主要参数有漏电流、电容值等。动态保护工作参数则能够表征系统受到静电放电脉 冲攻击时,器件泄放脉冲电流、保护后级组件不受ESD脉冲损伤的能力,主要参数有导通时间、钳位时间、钳位电压、峰值电压、峰值电流等。

TVS二极管的鲁棒性较高,通常都能满足电路设计要求,不是选件的首要考虑因素。由于工艺原因,TVS二极管的静态工作参数相差不大(尤其是同一生产商的情况下),静态工作参数常作为参考参数衡量器件是否满足设计要求。根据ESD设计窗的要求进行ESD设计时,动态保护工作参数是设计 师们主要的考虑因素。静态工作参数和鲁棒性都可以直接测量。本文搭建系统测量TVS的动态保护工作参数,并结合标称参数,分析TVS的ESD防护能力。

2.2实验方案

为了能够有效评估器件的ESD防护能力,并模拟真实工作情况,本文设计的测试方法原理如图2所示。其中,50Ω电阻模拟了后级受保护结构,它 由特征阻抗一定的测试系统构成,能够直观地测量得到保护器件的电压钳位能力;电流采样电阻用于观测器件的泄流能力,用电流靶实现。使用ESD防护器件的目的是提升系统 ESD抗扰度,系统级测试标准为IEC61000-4-2标准[9],因此放电源选取为该标准中规定的人体金属模型接触式放电波形。

3测试结果与数据分析

3.1TVS器件对静电放电的响应

根据原理图搭建测试系统,并选取多个不同型号的TVS器件,依次设置放电电压为2、4、6、8kV,进行放电实验。根据电压和电流响应波形,得到器件对静电脉冲的响应规律。不同型号的响应规律相似,以型号为 P6KE68CA的TVS二极管为例说明,图3和图4为测试结果。

从图3和4图中可以看出,在静电放电脉冲开始后,电压迅速上升,TVS触发导通,电流瞬间增大,同时电压在几纳秒内降低到某一恒定值并维持稳定,而电流则升至峰值。之后随着脉冲的减弱,电流也随之降低,直至静电放电脉冲结束。

比较不同放电电压的波形,除峰值有所不同外,其余部分几乎重合,这表明TVS对不同放电电压响应的时间以及钳位效果相同。峰值电压主要受引线电感以及器件响应速度的影响,随放电电压的升高而升高。在脉冲刚开始的几纳秒内,TVS器件并没有完全触发,其电压幅值主要取决于注入静电放电 脉冲的大小;待 TVS完全导通后,ESD钳位电压变化不大,在85~110V之间,主要因为TVS的导通 电阻较小,大电流仅引起电压的微小变化。同时,由 于钳位电压相对稳定,当放电电压增加时,电流也随之增大,将ESD脉冲的能量释放到大地。

3.2TVS二极管的标称参数与ESD防护能力的关联

TVS二极管的标称参数中,反向工作峰值电压和最大反向漏电流主要反映TVS在截止状态下的工作状况,而TVS的静电放电防护能力则与其在反向击穿状态下的参数有关,主要有反向击穿电压、最大反向峰值电流、钳位电压以及标称功率等。

(1)反向击穿电压

选取标称功率为600W、反向击穿电压分别为18、33、68、91、120V的TVS二极管进行测试,整理各器件在放电电压为2、4、8kV 情况下的峰值电压、钳位电压和峰值电流,并进行线性拟合分析,如图5-7所示。图中实心点为实测数据点,直线为数据点的线性拟合曲线。

在图5中,峰值电压的变化非常小,主要因为静 电放电波形具有很陡峭的上升沿,其上升时间小于TVS响应时间,因此TVS没能削弱该波形的第一个峰值,该峰值主要取决于放电电压。在图6和图7中,TVS的ESD钳位电压随着器件反向击穿电压的增加而增加,且略高于器件反向击穿电压,但峰值电流随着反向击穿电压的升高而略有下降,这说明器 件的反向击穿电压虽不能直接表明器件的ESD防护水平,但能定性的反映器件的ESD动态保护特性。

(2)标称功率

TVS标称功率是在10/1000μs的指数波形下 测量得到的峰值功率,但该测试波形与静电放电波形不同,因此需要讨论该标称功率与器件ESD防护效果的关系。分别选取标称功率为600W和1500W的几组TVS进行测试,其中一组的测试结果如图8和图9所示。

从图8和图9中可以看出,标称功率不同的TVS器件对同一放电电压的响应曲线几乎重合,标称功率与ESD动态保护特性无关。而且ESD峰值 功率要远大于器件标称功率,但器件仍能正常工作,说明标称功率不能直观反映器件对ESD的耐受能力。若要评定TVS的鲁棒性,还需要进行ESD抗扰度测试。

(3)钳位电压

由于TVS二极管并非理想器件,存在较小的导通阻抗,剧烈变化的电流仍能引起电压的微弱变化,因此只能给出TVS器件对ESD响应的钳位电压的 范围,难以定义具体的ESD钳位电压值。但结合图3可以看出,ESD钳位电压范围约为85~110V,略 高于标称参数的钳位电压68V。而且其他TVS器件也具有相同的规律,即ESD钳位电压范围略高于 标称参数钳位电压值。

其他标称参数,由于测试波形选取不同或应用范围不一致,与ESD防护能力不相关,不进行研究。

 

TVS的技术手册中给出了反向击穿电压、钳位 电压、峰值电流等参数,但其测量波形与静电放电波形有很大不同,因此手册中的参数不能有效反映TVS的静电放电防护能力。本文用人体金属模型作为放电源,对TVS二极管进行了ESD测试,并重点分析其标称参数与ESD动态保护特性的关系。

研究结果表明,器件标称功率既与ESD动态防护特性无关,也不能直观反映器件的鲁棒性水平,但标称功率与静态工作特性和器件鲁棒性是否关联有 待深入研究;标称钳位电压值与 ESD钳位电压值具有相同的数量级,但标称值略低于ESD的钳位值,不能直接将标称值应用于ESD设计中;反向击穿电压与ESD防护能力关联性最大,却难以直接反映ESD防护的具体参数值,但ESD峰值电流、ESD钳位电压与反向击穿电压呈线性关系,基于本文所绘曲线,可以对TVS器件的ESD防护参数进行估计, 同时也可根据实际需求(如电路所需钳位电压、泄放电流大小等)选择 TVS二极管的型号。总之,TVS二极管的标称参数并不能全面地反映器件的ESD防护能力,选用TVS二极管进行ESD设计时,还需进行详细测试以确定选件标准。本文的研究给工程师在选择TVS进行静电放电防护设计时提供了理论基础和指导性意见。

Posted on

TS001 用于ESD分析的传输线脉冲测试——元件级

这篇PPT介绍了关于静电放电(ESD)、如何进行ESD测试、什么是传输线脉冲测试以及问答。

ESDEMC_TS001_Introduction of TLP for ESD Analysis – Device Level

ESDEMC_TS001_用于ESD分析的传输线脉冲测试——元件级

作者Wei Huang、Jerry Tichenor、David Pommerenke

Introduction of Transmission Line Pulse (TLP) Testing for ESD Analysis – Device Level from Wei Huang

用于ESD分析的传输线脉冲测试 (Transmission Line Pulse – TLP Measurement) 元件级 from Wei Huang
Posted on

PB2014.08 以太网线缆放电事件(CDE)测试和测量系统

下载PDF –  以太网线缆放电事件(CDE)测试和测量系统

AN ETHERNET CABLE DISCHARGE EVENT (CDE) TEST AND MEASUREMENT SYSTEM

Abstract — A Cable Discharge Event (CDE) is an electrostatic discharge between a cable and a connector. CDEs occur on unshielded Ethernet based communication interfaces and inject currents into the pins directly [1-3]. The charging processes are in general understood; however, the discharge processes are complicated due to the number of pins involved and their connections to a system. Based on an understanding of the factors which determine the severity of a CDE, this article describes how to setup a variety of repeatable CDE tests and how to analyze the measurement results.

Keywords — Cable Discharge Event (CDE) Test; Cable ESD;

关键词:线缆放电事件(CDE)测试、线缆静电放电

 I. INTRODUCTION

Both occurrence rate and severity of a CDE needs to be considered when determining the importance of dedicated CDE tests to ensure a reliable system. The occurrence rate of a CDE depends on the type of connector used and the environment the system is used. While a USB connector on a laptop will receive many more ESD events than a LAN connector, the LAN connector still poses a larger risk to the system as it is usually not shielded and often used in applications that require high reliability such as back bone internet routers. In contrast to a USB connector, a LAN connector can have a spark from the connector to a pin during a CDE. In the case of USB connectors the connector shells will mate first. Provided that the shells are connected to the shield and to the system ground, most of the discharge current will flow on the connector shells.

For the LAN CDE case a good understanding of the dominating processes provides a mean for developing and validating models. These models will allow computer simulation, and laboratory test setup formulation for reproducing real CDEs. This is crucial for IC and system level engineers to study and optimize the immunity of Ethernet based communications interface designs.

It is well known that triboelectric charging is the culprit that generates the charge on a cable [1],[2]. This fact is especially important in Ethernet communication systems due to the long lengths of UPT cable that must be pulled through conduit, which may result into large charges. A model for describing the interaction of one twisted pair in a UTP (Unshielded Twisted Pair) cable is presented in [2] using a three body model analyzed from an electrostatic point of view. In [3] a system for discharging a cable using a relay on a test bed is presented, and experimental results are shown. In regards to the measurement analysis side of Ethernet CDE, there are few publications discussing the phenomena. Some ESD test setup have been developed to repeat ESD current transfer through Ethernet magnetic effects in [4] and [5].

The focus of this article is to present a CDE testing system that will allow for real world test conditions to be reproduced in the laboratory, thereby providing design engineers a quick and reliable method for testing new hardware designs. The test system will allow for different types of copper based Ethernet cables, and twisted pair termination strategies. Further, full control of the charge and discharge sequence of each cable line allows for all possible cases to be explored.

II. IMPORTANT PARAMETERS IN ETHERNET CDE

Prior to discussing the CDE test system, a few important parameters of copper based Ethernet cable CDE, especially UTP must be reviewed.

A. Parameters of the charged Ethernet cable affecting CDE

Several important parameters must be considered in UTP cables. The first parameter is the charging processes in UTP cables. In particular, the wires can be charged due to charges on the outside of the jacket, due to migration of charges through the jacket and insulation to the wires, or due to direct contact of the wires with a charged object. The voltage magnitude can be as high as 2 kV. In most cases all wires will be charged to the same voltage. If the spatial arrangement of the cables is changed, the capacitance between the charged wires and ground will also change, which can further increase the charge voltage.

Another important parameter to consider is that there are shielded and unshielded cables for Ethernet. These cable types are illustrated in Fig. 1. They all maintain 100 Ohm differential impedance for each twisted pair, but the unshielded cable will have relatively large common mode impedance (100-300 Ohm) versus the shielded cables because their current path is physically far from the ground as compared to the shielded wires. This common mode impedance plays a critical role in the magnitude and to a lesser extend in the shape of the CDE discharge current waveform.

B. The termination of the Ethernet device

Load terminations also play an important role in the characterization of a CDE. Many different types of termination schemes exist, however, the most commonly used is the Bob Smith Termination [5]. This termination uses a 75 W resistor for a common mode impedance match at each signal pair, and they all connect via a high voltage capacitor to chassis ground as shown in Fig 2. The isolation between the Ethernet connector/chassis and internal PHY circuit is established through a transformer and some designs incorporate common mode chokes to further reduce common mode current motivated EMI concerns. Further variations of the Bob Smith circuit can be found in power over Ethernet applications, and strongly cost reduced designs.

One pin will make the first contact and any other pin will contact next. The initial contact leads to a charge redistribution, a partial discharge of the total charge on the cable, and it can charge the capacitor used in the Bob Smith circuit. Depending on the contact sequence, various common mode and differential mode termination plus the PHY IC circuit determine the load of the discharge current path and therefore are the important factors that determine the CDE current waveform.

C. The ESD events during CDE

The Ethernet cable connection includes several metal to metal contacts, which can lead to multiple ESD events during connection. For the case of plugging a shielded Ethernet cable into a shielded Ethernet connector, the first ESD event is the discharge between the shielding of the cable to the shielding of Ethernet connector as this is the first contact point. Normally this ESD is not likely to cause any failures if the DUT is shielded. For the case of an unshielded cable or an unshielded Ethernet connector the current must flow in the wires of the UTP.

When an Ethernet cable is plugged into a connector, many possible contact sequences can occur. Theoretically there could be eight separate ESD events, one for each pin. However, each contact will minimize the voltage between the other pins and the connector. This is caused by the large mutual capacitance between the wires, and by charging the Bob Smith Termination.

To illustrate the charging of the capacitor in the Bob Smith circuit, a 100 m long shielded cable was charged to 100 V between the shield and its wires and inserted into an Ethernet device. A result from this experiment is shown in Fig 3. Because the capacitance between the wires and the shield is much larger than the 1000 pF capacitor, the voltage reaches over 90 V immediately after first contact, thereby lowering the voltage difference between other connecting pins. For the next seven contact events the voltage difference across the contacts is drastically reduced.

The voltage waveform shown in Fig 3 gradually diminishes due to the 100 MW resistive voltage probe used in the measurement. Without this drain path the voltage on the cable will remain high for a very long time after the connection is made. If the other end of this cable is plugged into an Ethernet device another cable discharge event may occur.

Because the differential pairs of the cable have a welldefined 100 W discharge impedance, after the first wire has made contact and the high voltage capacitor has a low impedance path to ground, such that the second wire also experiences the discharge as it is making contact, resulting in a differential ESD event. This differential ESD current can easily transfer through the magnetics to the isolated PHY circuit, which is hazardous for the PHY chip.

III. THE ETHERNET CDE TEST SYSTEM CONCEPT

A good Ethernet CDE test setup should be able to control as many of the parameters related to the cable discharge event as possible, and provide a repeatable test. To do this the setup must have these three main components; a Controller, a Charge Module, and a Failure Test Monitor.

The Controller must have the capability to control cable charge voltage and polarity, charge and discharge different types of Ethernet cable arrangements, and separately control the charging, floating, grounding, or discharge of each wire. In addition, the test system should maintain the electrical characteristic of the entire discharge current path as close to real world CDE cases as possible. In particular, it should control common and differential mode impedance of each pair, and the contact sequence delay time between each discharge to the same order of magnitude of a real cable as it is plugged into a device.

The Charge Module represents the Ethernet cable used as the discharge source for the CDE event. This consists of different lengths of various CAT5 cable types. For research purposes, different types of cables and how they are arranged must be studied. For industry testing purposes, a good charge module will provide a worst case, real world CDE source.

ill provide a worst case, real world CDE source. The Failure Test Monitor provides a means for verifying the Ethernet performance. It will check if a failure has occurred, or simply if a degradation in communication speed has occurred. It is important this is automated due to the vast array of tests that can be performed to check all discharge sequences. A general block diagram of the CDE test system is shown in Fig 4.

A. CDE Test Controller

The main CDE test controller consists of high voltage supplies (dual polarity), relays to separately control the connection of each Ethernet cable wire, including whether it is charging, floating, or grounded. The relays are bounce free and provide a clean discharge for each wire. The transmission lines on the board maintain the controlled 100 W differential pair structure of the Ethernet cable, and current probes are embedded into each wire to monitor CDE discharge current. The system also has remote control capability integrated into the upper level system as a part of the automatic test equipment (ATE). A simplified diagram of the main CDE controller is shown in Fig 5.

A common test procedure may consist of the following four steps, as illustrated by the block diagram in Fig 6.

1. Charge cable status control

The controller separately controls the voltage (level and polarity) for each wire in the cable bundle. This includes the status of each wire indicating if it is charged, floating, grounded, or a through path.

2. Pre-discharge preparation

The controller will disconnect the charging path from each wire in the Ethernet cable bundle and disconnect the DUT discharge path between the DUT connector and ground. This will leave all wires floating before the discharge step.

3. Control wire discharge while monitoring ESD Current

The controller will close the relays allowing the wires coming from the charge line to discharge into the DUT or termination load. The sequence of the relay closure and the delay between relay closures can be set by the user.

4. Preparation after a discharge and check DUT status

The controller will open all cable discharge relays such that the cable can be charged again. To charge the wires the high voltage charging relays are closed. In additional all remaining charges on the DUT need to be removed. This is achieved by closing the DUT discharge relays.

The controller will open all cable discharge relays, then close all high voltage charging relays and DUT connector discharge relays to prepare for next CDE test.

B. Charge Module

In real world Ethernet cable installations there are many different possibilities in regard to cable type and arrangements, leading to unlimited test scenarios. Some common real world arrangements are:

A. Cable hanging on the celling (relatively far from ground)

B. Cable on the floor (very close to the ground)

C. A spool of new cable

D. Cable pulled through conduit (very close to the ground)

C. Failure Test Module

Besides the setup for CDE test control, it is also important to test for normal Ethernet performance and functionality. It is important to understand the effects of applied CDE on the DUT, and as in the block diagram of Fig 4, an Ethernet traffic test system should not only monitor the status of DUT during CDE test, but also check the performance of the CDE applied ported after each test level.

D. Calibration of the Ethernet CDE Test System

A CDE Tester (Model ES631-LAN) with two different types of Ethernet Charge Modules (shielded and unshielded) was built. The analysis of real discharge waveforms is difficult. For that reason a proper calibration method with well-defined test loads is important to verify the functionality, to understand the current paths and the output parameters of the CDE test setup. A set of calibration loads including short, open, and 100 W differential load were built using 10 cm CAT5E UTP cables, and are shown in Fig 8.

The EIA 568B cable standard was used for all Ethernet wiring, Fig 9.

In the measurement setup the oscilloscope was set to capture the waveforms: Channel 1-voltage on line 5, Channel 2-current on line 5, Channel 3-voltage on line 4, and Channel 4-current on line 4. The voltage probes were 1010:1 (5 kW/50 W resistor bridge = 101:1, plus 20 dB attenuator). And the current probes were 20:1 (5 V/A plus 40 dB attenuator). The CDE Controller in all tests was set to 500 V, and depending on the test configuration the Charge Module and DUT may have been grounded.

Setup 1 consisted of a short connected to CDE Controller output, one differential pair with one side grounded and preconnected to the load, and a 100 meter Charge Module using S/UTP cable with the chassis not grounded. The setup and measurement waveforms are shown in Fig 10. From the simplified circuit, after the relay is closed in line 5, we expect a large current flowing from line 5 to line 4 over the differential 100 W transmission line structure and the peak current should be 5 A (500 V/100 W). From the waveforms it can be confirmed that the current waveform starts with 5 A peak. Then the waveform shows significant cable loss as the waveforms rapidly decay. After the current reaches the cable ends, reflections occur due to mismatches and several reflections happen until the total signal approaches zero. The voltage is a RC discharge waveform through the voltage measurement path.

Setup 2 is similar to setup 1 except the charge module chassis is connected to ground. The setup and measurement waveforms are shown in Fig 11. As can be seen, the current waveforms are the same as the first setup, but the voltage waveform RC time constant is much larger due to the grounding of the Charge Module chassis.

Setup 3 consisted of an open load connected to the CDE Controller output, one differential pair with one side grounded and pre-connected to the load, and a 100 meter Charge Module using S/UTP cable and chassis grounded. The setup and measurement waveforms are shown in Fig 12. There is little displacement current as the load is an open, and the voltage on line 5 is 494 V peak, which is very close to the charge voltage.

Setup 4 consisted of a 100 W load (with center tap between two 50 W resistors grounded) connected to the CDE Controller output, one differential pair with one side grounded and preconnected to the load, and a 100 meter Charge Module using S/UTP cable and chassis grounded. The setup and measurement waveforms are shown in Fig 13. With the 100 W load in place the current waveform magnitude drops to half of that measured with the short as in setups 1 and 2, and there are no reflections.

Except for the shape and magnitude of the measured calibration waveforms, the time delay of the measurement is also important to understand, in particular, which part of the waveform is due to the 100 W transmission line extension, and which part is due to the DUT. The waveforms shown in Fig 14 are with the CDE Controller connected to a CAT5E UTP cable only. The current waveform shows the 100 W transmission line extension first, then the open end. The real measurement of the DUT starts at the time where the open is shown.

E. Test of the CDE System on Ethernet Systems

Two 10/100Mbps Ethernet DUTs were tested with the CDE test system as shown in Fig 15. The test parameters are: CDE source voltage of 1 kV, a 100 meter Charge Module using S/UTP cable, and oscilloscope channels are scaled to 1 A/div. The first pin discharge waveform is captured and compared between unit A and unit B. Unit B has a much smaller current peak and higher current duration. This is mainly because the common mode impedance of unit B is much smaller than unit A.

Most systems using the Bob Smith Termination are almost fully charged after the initial discharge, so the current magnitude of the 2 nd – 8 th discharges are too small compared to the first one. This is not discussed here.

A Power over Ethernet (POE) system, having more complex termination was also tested. The measurement waveforms are shown in Fig 16. When the first pin contact DUT, first discharge current is generated in common mode through this pin. Then when the other wire in the same twisted pair contacts DUT, another discharge current is generated in differential mode through this pair. Both discharge signals could be transferred from termination to PHY circuit leading to damage in the Ethernet system.

IV.CONCLUSION

In this article, several important physics for CDEs have been discussed, a general CDE test and measurement solution developed, and some test results with well-defined structures and a few real world Ethernet systems are presented and discussed.

The next steps for CDE related test and measurement would be modeling the overall test system with different terminations, and running more tests with Ethernet systems to understand the design principle for CDE.

ACKNOWLEDGMENT

We would like to thank the EMC Laboratory, Missouri University of Science and Technology for the partnership of CDE related study and research and Cisco for the partnership in CDE related tests and measurements.

Posted on

TN006 VF-TLP测量的先进频率补偿方法(高达10 GHz)

TN006_P09 ESDEMC Frequency Compensation of VF-TLP Voltage Measurement Flow Diagram

 TN006 VF-TLP测量的先进频率补偿方法 (PDF)

1. 目标

本文的目的是演示一种频率补偿技术,用于在极快传输线脉冲发生器(VF-TLP)测试环境中测量被测设备的电流和电压。电流测量利用非重叠时域反射法,这对于晶片测试很有用,因为可以使用低轮廓小间距探针进行测量,例如Picoprobe型号10。此外,为了比常见技术(例如1GHz带宽的电流互感器)增加电流测量的带宽,该方法利用电阻传感器。可以对拾取进行微调,使插入损耗尽可能小,从而提高带宽。虽然这种方法也可以产生DUT电压测量,但对于低欧姆器件,结果存在数值误差。本文介绍了一种单独的直接测量方法,该方法将展示一种极其精确的电压测量方法,该方法还利用了频率补偿。

 

2. 测量设置

超快传输线脉冲或VF-TLP测试是一项很难很好执行的测量。这是一个高带宽测量,必须尽可能完成所有连接,以保持系统的特性阻抗(通常为50). 这意味着确保任何探针连接都匹配良好,并且任何连接器/适配器都具有尽可能高的质量。此外,由于如何实现非重叠TDR测量,使用低损耗电缆有很大的好处,这是非常昂贵的。

整体测量设置如图1所示,从图的最右侧可以看出,系统可以适应各种DUT连接方法。特别是,通过连接中的脉冲将脉冲施加到DUT,并在Vm连接处进行直接电压测量。可以使用两个探针进行真正的开尔文测量,从而提供良好的晶片测量解决方案。图中还可以看到ES621传输线脉冲发生器、拾取三通、泄漏控制模块(A621-LTKSEM)、源-表单元(SMU)和示波器。带圆圈的数字表示非重叠TDR电流测量的频域测量点的位置。在正常脉冲条件下,泄漏控制模块连接处于常闭(NC)位置。在泄漏电流测量条件下,模块处于常开(NO)位置。NO位置将DUT连接到SMU,并断开电压测量电阻器Rv。设置的照片如图2所示。

Figure 1 ESDEMC ES62X Series VF-TLP Measurement Setup
图1 ESDEMC VF-TLP测量设置

 

Figure 2 ESDEMC ES62X Series VF-TLP Delay Line Cable Arrangement
图2 ESDEMC VF-TLP延迟线电缆布置

2.1 电流测量

图3显示了一个强调测量的非重叠TDR连接的简化图。从左侧,TLP连接到布线布局的端口1。V+表示TLP的正向输出波。接下来是电阻拾取,当V+向DUT传播时,测量入射或(V+M)。到达DUT后,反射波(V-L)向要测量为V-M的传感器传回。传感器和DUT之间的电缆标记为延迟线。这是因为该电缆的长度必须足够长,以便在入射波完全通过之前延迟反射波到达传感器。如果延迟线至少比脉冲宽度长两倍,则可以保证这一点。延迟线长度和对低损耗电缆的需求通常导致该测量方法的脉冲宽度不超过10纳秒。

ESDEMC ES62X Series Non-Overlapping TDR connections
图3 ESDEMC VF-TLP非重叠TDR连接

被包围的数字(○1.○2,和○3) 图3表示必须进行频率补偿测量的位置。特别是,必须测量并保存S21、S31和S32,以备将来用于每个测量设置。如果任何电缆或衰减器或传感器发生变化,则必须重新测量S参数。泄漏控制模块必须包括在测量中,并处于常闭状态。典型设置的三个S参数的幅值如图4所示。在所有频率上,电缆和拾取的插入损耗最好为0 dB,允许将完整的TLP输出脉冲应用于DUT。然而,真正的低损耗电缆在10千兆赫时可能有几分贝的衰减。对于测量的设置,损耗的增加最有可能来自拾取和连接漏电继电器和DUT的端口之间的SMA连接器。另一项需要注意的是,S21测量值相对平坦。

Magnitude of S-parameter measurements for the Non-Overlapping TDR setup
图4 非重叠TDR装置的S参数测量值

其他两个S参数测量非常相似,这是意料之中的,因为除了路径中具有更长延迟线的S32之外,连接是相同的。幅值测量中的纹波是由于连接中的反射引起的。纹波约为1 dB至1 GHz。如何使用这些测量的S参数将在第3节中介绍。

2.2 电压测量

如前所述,非重叠TDR测量确实产生DUT电压测量。然而,对于低欧姆器件,测量存在数值误差。这是由于在处理捕获的数据时使用了传输线理论数学,将在第3节中进行更详细的解释。通过单独的直接测量可以实现DUT电压的良好测量,简化的连接图如图5所示。
这种测量通常非常精确,只需使用探头比和衰减器值来计算DUT电压。然而,由于VF-TLP型测量具有更高的带宽限制,可以通过使用频率补偿实现更精确的测量。与非重叠TDR一样,电缆损耗、衰减器值和连接质量都可以通过捕获测量系统的S21来表示和补偿。系统的S21测量值如图6所示。
VF-TLP Direct Voltage Measurement Setup

图5. VF-TLP直接电压测量设置

 

Magnitude of S-parameter measurements for the Voltage Measurement
图6 电压测量的S参数测量值

出于将在下一节中解释的原因,图6中测量的探针连接是图1中的PCB或右上侧子图。测量相对平坦到1 GHz。

 

3. 频率补偿

处理捕获的数据需要将S参数数据加载到TLP测量控制代码中。使用所有网络分析器支持的Touchstone文件格式可以轻松实现这一点。该方法中处理的核心是在频域中完成的,这意味着必须将测量的时间波形转换到频域。由于几乎不可能确保时间记录长度与测量的S参数相同,因此必须进行插值以获得等长的数据集。

IDUT的非重叠TDR测量流程图如图7所示。图的左上角显示了捕获的非重叠TDR波形图。在图中,左手脉冲是拾取测量的入射脉冲(V+M),右手脉冲是拾取测量的反射脉冲(V-M)。处理的下一步是准备好将数据转换到频域。在此步骤中,对入射和反射脉冲进行分离、加窗、滤波和插值。特别是,脉冲在切割点处分离,切割点是任意的,只需要位于两个脉冲之间。如果延迟线改变或脉冲宽度改变,则应验证切割点处于适当位置。需要加窗以强制将时间记录的开始和结束归零,以确保捕获的数据在FFT方面呈现周期性。如果不这样做,FFT结果将遭受频谱泄漏。接下来,如果需要,可以过滤数据。在本文给出的结果中,没有对数据进行过滤。最后,对时域和频域数据进行插值。

流程图中的下一步是通过快速傅立叶变换(FFT)变换时间数据。这里没有显示其他数学操作,但数学在流程图的下一步中进行了说明。该操作将两个拾取测量值(V+M和V-M)转换为负载/DUT。特别是,必须将测量的入射波(V+M)转换回TLP(除以S31),然后转换成载荷(乘以S21),产生V+L。由于测量的反射波(V-M)仅在载荷和测量端口之间穿过,因此只需要通过除以S32转换回载荷,产生V-L。

ESDEMC VF-TLP Non-Overlapping TDR Processing Flow Diagram
图7. ESDEMC VF-TLP非重叠TDR处理流程图

然后,通过逆FFT(IFFT)获得负载处入射波和反射波的时域表示。这两个波形显示在IFFT流程图步骤左侧的图中,放大版本如图8所示。请注意,这两个脉冲之间存在时间差。S参数测量应该考虑到这个时间差,并给出与它们完全相同的连接。然而,由于必须使用形状记忆合金适配器连接到各种不同的端口,因此无法将所有测量值放置在校准平面上。幸运的是,这种差异很短(通常为皮秒),可以通过从反射脉冲中减去时间来解释。

V+L and V-L waveforms (Zoom).
图8. V+L和V-L波形 (缩放).

最后,可以计算负载电流或IDUT,如流程图的最后一步所示。注意,对于低欧姆器件,产生的脉冲在幅值和相反方向上具有可比性。这种组合有利于确定电流,因为结果是两个具有可比大小的数字相加。然后将其除以特性阻抗以获得电流。如前所述,这不是测量DUT电压的好方案。考虑到相同的脉冲,具有相似的幅值和相反的方向,电压的结果是两个相似数字的减法,并且可能产生更大的误差。这种方法非常适用于高欧姆器件的电压测量,但由于类似的原因,电流测量也会受到影响。

直流电压测量的处理与电流测量非常相似,流程图如图9所示。在通过FFT变换之前,对数据进行加窗、滤波(如果需要)和插值。频域操作仅通过除以测量路径的S21将示波器上记录的测量值转换回负载。图9的左上角和左下角分别显示了DUT波形的原始电压和产生的电压。注意补偿是如何消除探针引入的电压测量上的过度振铃的。

ESDEMC VF-TLP Voltage Measurement Flow Diagram
图9. ESDEMC VF-TLP电压测量流程图

4. 测量

上述方法的目标是获得尽可能最佳的高带宽测量,该方法利用频率补偿来尝试实现这一目标。为了证明该技术的能力,对同时记录的两个不同电压测量值进行了比较。要做到这一点,1 电阻器与测量电阻器(Rv)一起安装在PCB上,如图1右上角所示。图1的连接有一个例外,即增加了一个可直接馈送至示波器的直通端口。PCB的示意图和照片如图10所示。DUT从脉冲输入连接到接地,使有效DUT成为1的并联组合 带有示波器输入阻抗的电阻器(1欧姆| 50欧姆)。通过侧测量通过30 dB/18 GHz衰减器直接连接到示波器通道3。通过测量仅由衰减器的值补偿。

Photo of VF-TLP DUT test PCB
图10. VF-TLP DUT测试PCB图

为了真正测试和理解系统的能力,本文简要介绍了将用于为DUT提供脉冲的脉冲形状特性。首先,ES 621 TLP可以产生非常干净且快速上升的脉冲,如图11所示。使用泰克MSO 72304DX(23 GHz/100 GSa/s)示波器、18 GHz短电缆和衰减器进行测量。如图左下角所示,平均上升时间测量值约为60 ps,平均脉冲宽度测量值约为1.04 ns。此外,超调量很小并且很快解决。

ES 621 Vf-TLP output, 60 ps rise time, 1ns pulse, with 23 GHz Oscilloscope
图11. ES621 Vf-TLP输出, 60 ps上升时间, 1ns脉宽, 使用23 GHz示波器, 于SDEMC总部Rolla, MO, USA 2014/08/28测量

 

图12所示为电流测量结果。黑色轨迹是原始结果。raw表示最终测量的电流值是通过在时间上对齐入射和反射波形,通过测量路径中的拾取探头值和衰减器对其进行缩放,然后使用图7中流程图底部的等式来确定的。红色轨迹是相同的测量结果,但它是上述频率补偿方法后的结果。可以看出,两个测量值在一般形状和振幅方面非常一致。但是,频率补偿测量消除了测量探头引入的伪影,例如电流脉冲开始时的高频纹波。

ESDEMC VF-TLP Raw and Frequency Compensated Current Measurement
图12 ESDEMC VF-TLP原始和频率补偿电流测量

图13所示为电压测量结果。黑色轨迹是原始直接电压测量值,仅由探头因子和衰减器值进行缩放。红色轨迹是相同的测量结果,但它是上述频率补偿方法后的结果。蓝色轨迹是VThru,是直接电压测量和30 dB/18 GHz衰减器作为唯一补偿的结果。可以看出,红色和蓝色轨迹非常匹配,支持频率补偿技术在获得电压测量值方面做得非常好。

Raw, Frequency Compensated, and Thru Voltage Measurement
图13. 原始、频率补偿和通过电压测量

5. 结论

本文的目的是演示一种频率补偿技术,用于在极快传输线脉冲发生器(VF-TLP)测试环境中测量被测设备的电流和电压。结果表明,通过将测试装置的S参数测量纳入处理程序,可以获得非常好的电压测量。特别是,使用高带宽直接电压测量来验证VF-TLP电压测量。类似地,使用补偿方法从非重叠TDR测量中获得器件电流。

ESDEMC 60ps rise-time 1ns Pulse VF-TLP Measurement
ESDEMC VF-TLP 60ps上升时间1ns脉宽VF-TLP脉冲测量

附录:测量设备

Tektronix MSO 72304DX, 23 GHz/100 GSa/s, 示波器
ESDEMC ES621传输线脉冲系统
ESDEMC A621-LTKSEM漏电控制模块
ESDEMC FS312 VF-TLP电压探头
Suhner Sucoflex 100高性能微波线缆
Micro-Coax UTiFlex超低损微波线
Mini-Circuits SMSM线缆
Gore-Tex超低损同轴线缆

Posted on

PB2013.08 冷却对低信号强度RFI问题探针系统灵敏度的影响

下载PDF – 冷却对低信号强度RFI问题探针系统灵敏度的影响

EFFECT OF COOLING ON THE PROBE SYSTEM SENSITIVITY FOR LOW SIGNAL STRENGTH RFI PROBLEMS

Abstract—Only highly sensitive probe systems can detect the weak field strengths that cause radio-frequency-interference (RFI) problems typically found within cell phones. The sensitivity of the probe systems depends on the probe factor and on the noise floor. The effect of cooling by liquid nitrogen on the received signal strength and the noise floor of three resonant probe systems has been investigated. They operate at the GSM, GPS, and WiFi frequency bands. Cooling increases the Q-factor of these resonant probes, increases the received signal, and lowers the noise floor. The sensitivity of the system, defined as the signal strength at which the Signal-to-Noise Ratio is equal to 0 dB improves by 3-6 dB.
Keywords— Quality factor, radio-frequency interference (RFI), resonant magnetic field probe, signal-to-noise ratio.

关键词:特征因数、射频干扰(RFI)、磁场探头、信噪比

I. INTRODUCTION

High-frequency harmonics generated from the digital ICs and switched power supplies may couple into the antennas which are integrated into mobile systems such as cell phones. The noise of the harmonics is added to the natural noise floor of the receiver and overwhelms weak signals which should be received by the receiver [1], [2]. Near-field probes [3], [4] and scanning technique are effective tools to investigate noise field distribution of circuits at high frequency and to locate the source of the EMI problems at circuit and chip level [5], [6].

Broadband probes are useful tools for initially locating strong noise sources. Magnetic near-field probes for high frequency band up to tens of GHz have been designed by suppressing the inherent resonances of a circular loop [7], and by minimizing the cross-sensitivity of electric near-field [8]. However, when the interfering electromagnetic fields are weak, it is difficult for broadband probes to measure signals of low signal-to-noise ratio (SNR). Probes with larger loop size can improve the SNR but degrade the spatial resolution. Since the noise source of interest is usually in the narrow bands, narrowband resonant probes can detect lower SNR signals than their broadband counterparts because of their higher sensitivity [9], [10]. In the applications of nuclear magnetic resonance (NMR), the SNR is further improved by lowering the coil temperature with liquid helium, since the noise is dominated by the thermal noise of the receiver coil in a welldesigned NMR spectrometer [11], [12].

In the following paper, three resonant magnetic field probes are cooled with liquid nitrogen to investigate the effect of cooling on the probe system sensitivity, where only the probes are cooled. The probes operate at the GSM, GPS, and WiFi frequency bands. The sensitivity is defined as the signal at which the SNR reaches 0 dB within a bandwidth of 1 Hz. The experiment and results are described in detail in the following sections.

II. PROBE UNDER INVESTIGATION

The probe for investigating the effect of cooling is based on a differential-loop resonator shown in Fig. 1 and a Marchand balun based impedance transformer shown in Fig. 2. The theory, design and the dimension of the probe have been introduced in detail in [10]. The probe uses a four-layer FR4 printed circuit board. The initial design selected FR4 as substrate due to its low cost. The top and bottom layers in Fig. 1 are signal return planes and shielding planes minimizing unwanted field coupling. The LC resonator consists of a parallel-plate capacitor in parallel with an inductor formed by the probe loops. The resonant frequency of the probe is set by the geometry of the loops and the capacitors. The resonator is terminated with a Marchand balun based impedance transformer. The impedance transformer converts a high impedance Zl of 1800 Ω to a low impedance Z0 of 50 Ω. The high impedance is loading the resonator but allowing for a high Q-factor. The low impedance matches to the input impedance of measurement instruments such as the spectrum analyzer for maximal energy transfer. The transformer also converts differential signals to a single-ended signal, where the differential signals originate from the mirror-symmetrical design of the resonators on the second and third layers. Drawing of the fabricated resonant magnetic field probe at GPS frequency band are shown in Fig. 3. The assembled probe is about 6.5 cm long from the SMA connectors to the probe tip.

III. MEASUREMENT SETUP

Fig. 4 shows the measurement setup for investigating the effect of cooling probes by liquid nitrogen. The tracking generator of the spectrum analyzer outputs a sweeping sinusoidal signal to drive the 50 Ω microstrip trace terminated by a matched load. The probes are placed 2 mm (H = 2 mm, in Fig. 4) above the trace. This height is in the same order of the height commonly used in the near field scanning. The signal is amplified by a three-stage amplifier and then received by the spectrum analyzer. The amplifiers are connected to the probe output port directly.

The first stage amplifier, Amp1, is a narrow band low noise amplifier (LNA). The second and third stage amplifiers, Amp2 and Amp3, are broadband. The noise figures and gains are listed in Table I at the frequency bands of interest. The system noise figure attributed to the noise contribution of each stage amplifier in the cascade follow the Friis equation:

where NF is the system noise figure, NFi (i=1, 2, 3) is the noise figures of three amplifiers, and Gi (i=1, 2, 3) is the gain of three amplifiers. All the probes are matched to 50 Ω at their center frequencies. Therefore, the noise figure of amplifiers measured in a 50 Ω system is a reasonable estimate for calculation in Eqn. 1. All the values in Eqn. 1 are linear scale, not in decibels. The system noise figures are 0.6 dB, 0.9 dB, and 1.1 dB for GSM, GPS, and WiFi frequency bands, respectively. The system noise figure is mainly influenced by the LNA, which has a low noise figure and relatively high gain.

IV.COOLING EFFECT ON THE PROBE Q-FACTOR

The probe’s Q-factor was measured at room temperature and after cooling the probe in the liquid nitrogen. Although liquid nitrogen is not readily available in a real-word EMC laboratory at present, it is easy to buy a tank of liquid nitrogen. One might pour the liquid nitrogen onto the probe using a pipe during the real-world measurement. In the initial test, however, the probe is immersed in nitrogen. During the cooling, only the PCB of the probe has been placed into the liquid nitrogen for three minutes. The probe can stay cold for approximately two minutes after it is taken out from the liquid nitrogen. Then the probe was placed 2 mm (H = 2 mm) above the trace to measure signals, as shown in Fig. 4.

Cooling the probe increases the resonance frequencies (see Fig. 5). Take the GPS probe as an example. The resonance frequency increases by 46 MHz. The 3 dB bandwidth decreases by 29 MHz. The probe’s Q-factor, Q, is calculated by

where fc is the center frequency of the resonance, BW3dB is the 3 dB bandwidth. The Q-factor when the probe is at room temperature is 11.3. After the cooling, the Q-factor is 14.7. The Q-factor increases by 3.4. Similar results for GSM and WiFi probes are listed in Table II. Both a small increase in the resonance frequency, and lower losses result in an increase of the Q-factor.

From the power point of view, the power received by the spectrum analyzer increases by 1-3 dB at the center frequency. At the same time, the loss in the probe reduces. The thermal noise in the conductors for the signal traces and the ground planes decreases with decreasing temperature. The dissipated power becomes smaller, leading to the higher Q-factor.

V. EQUIVALENT MAGNETIC FIELD STRENGTH OF NOISE FLOOR

The minimal detectable signal can be defined as the signal at which the SNR reaches 0 dB within a bandwidth of 1 Hz, when the noise power is equal to the noise power density. Real bandwidths are much larger. However, it is easy to denormalize to any requested bandwidth from 1 Hz. To calculate the noise equivalent signal, the system probe factor, SPF, and the noise power density, Pn,r, at the output of the probe system is needed. The noise power density is read directly from spectrum analyzer R&S FSV. The system probe factor is obtained from calibration.

During the calibration, the matched microstrip trace is driven by a source with a power level of Pd at the resonance frequency fc . The input impedance looking into the microstrip trace at the driving port is Rin = 50 Ω. The voltage at the driving port is

The microstrip trace generates a magnetic field, which is measured by the probes. The probes output a power, Pr , to the spectrum ananlyzer. Since the input impedance of the spectrum analyzer is RSA = 50 Ω, the receiving voltage measured by the spectrum analzyer is

Therefore, the voltage transfer coefficient TV from the driving voltage Vd to the receiving voltage Vr is

We simulated the same matched microstrip trace driven by one Volt, and the magnetic field above the trace normalized to one Volt is Href in unit of (A/m)/V. In the measurement, the trace is driven by a voltage of Vd. The magnetic field strength, Hm, measured by the probe would be

The system probe factor, SPF, is defined as:

Once the system probe factor SPF is known, the magnetic field strength Hm can be calculated if the receiving voltage Vr is given. When the SNR of the signal probe measures is 0 dB, the probe outputs a noise power of Pn,r within a bandwidth of 1 Hz. The voltage measured by the spectrum analyzer then is

The equivalent magnetic field strength of the noise is

The measured equivalent magnetic field strength is listed in Table III, comparing the cooled and the room temperature cases. The cooling has changed the property of probe materials slightly. This change is reversible.

The driving power Pd is not the same when the probe is cooled and at room temperature. This is caused by a small frequency dependence of the cables losses, as the resonance frequencies shift slightly. It is also caused by a small variation of the tracking generator’s output power at different frequencies. However, the small difference of driving power has no effect on the system probe factor, since the system probe factor is normalized with respect to the driving power, normalizing to 1 volt driving voltage at a 50Ω resistor.

If we take the GPS probe as an example, the received signal increases by 0.8 dB when the probe is cooled. At the same time, the noise power density decreases by 3.89 dB/Hz. The higher sensitivity and the lower noise power density result in an increased sensitivity of 4.69 dB. When this value is converted to the equivalent field strength, the minimal detectable equivalent field strength is 4.8 nA m /)/( Hz lower when the probe is cooled. Similar improvements are seen for the other probes when cooled.

VI.CONCLUSION

The change of the system sensitivity by cooling near field probes for the GSM, GPS and WiFi bands using liquid nitrogen has been investigated. We observed increasing Qfactor, higher sensitivity, larger output power, and lower noise power density of the probe system at lowered temperature. The sensitivity of the system, defined as the signal strength at which the SNR is equal to 0 dB improved by 3-6 dB. The cooled probe system is helpful for detecting low electromagnetic fields coupled to RF antennas.

ACKNOWLEDGMENT

This material is based upon work supported by the National Science Foundation under Grant No. 0855878.

Posted on

PB2012.09 利用系统效率ESD设计(SEED)概念分析手机LED保护电路的应用

下载PDF – 利用系统效率ESD设计(SEED)概念分析手机LED保护电路的应用

AN APPLICATION OF UTILIZING THE SYSTEM-EFFICIENT-ESD-DESIGN (SEED) CONCEPT TO ANALYZE AN LED PROTECTION CIRCUIT OF A CELL PHONE

An application of utilizing the system-efficient-ESD-design (SEED) concept to analyze an LED protection circuit of a cell phone
Tianqi Li #1, Junji Maeshima *2, Hideki Shumiya*3, David J. Pommerenke#4, Takashi Yamada*5, Kenji Araki*6

# EMC laboratory, Missouri University of Science and Technology, 4000 Enterprise Dr., Rolla, MO, 65401, USA, tlx6f; 4 davidjp@mst.edu
* Sony Corporation, Sony City, 1-7-1 Kounan Minato-ku, Tokyo, 108-0075, Japan
2 Junji.Maeshima; 3 Hideki.Shumiya; 5 TakashiB.Yamada; 6Kenji.Araki@jp.sony.com

 

Abstract—An LED circuit of a cell phone is analyzed using the System-Efficient-ESD-Design (SEED) methodology [1]. The method allows simulation of the ESD current path, and the interaction mechanisms between the clamp and the on-chip ESD protection circuit. The I-V curve and the non-linear behavior under high current pulses of every component including R, L, C, and ferrite beads are measured and modeled. By combining all of the component models, a complete circuit model is built for predicting the circuit behavior and damaging threshold at a given setting-voltage of a Transmission Line Pulser (TLP).

I. INTRODUCTION

To build lower cost systems with better ESDresistant design at the system level it is important to understand the ESD current path, and how an IC’s on-chip protection circuit interacts with outside clamp circuits [2]. For example, if the on-chip ESD circuit of an IO pin could provide enough protection, then any external protection components could be omitted to reduce cost. A more complex case would be if the on-chip ESD circuit could not meet the protection requirements and the off-chip protection circuit has a relatively large resistance, more ESD current would still flow through the IO pin’s internal ESD circuit and finally damage the IO circuit itself. In this case, the external protection circuit should be replaced with a different clamp with smaller resistance in order to protect the IO pin.

For this reason, the interaction between components, especially between different protection circuits inside a system needs to be thoroughly analyzed, to achieve a more efficient protection scheme at the system level [1]. This is the purpose of the SEED approach. Circuit modelling and simulation is a convenient approach for such SEED analysis. However, typical SPICE models of components cannot be used in these simulations because they usually only contain information for normal operating conditions, without responses to several kV pulses such as those seen in ESD strikes. In this project a TLP is used to measure transient IV characteristics of each component, and highvoltage-SPICE models are built based on the tested data [3].

In this paper, an LED circuit in a cell phone is chosen to demonstrate the SEED analysis approach. The schematic of the LED circuit is shown in Fig.1. Under typical working conditions the VCC pin outputs DC current that flows through the LED and is sunk by the IO pin. The driver IC controls LED turn-on and turn-off by changing the status of the output MOSFET. All other components such as capacitors and Zener diodes are used for ESD protection and other filtering purposes. A potential discharge point is at the LED, which is located near the cell phone’s keyboard.

A. Modeling the LED

The I-V curve of the LED has been measured using a TLP resulting in the SPICE model shown in Fig. 2. The model includes two parts: the normalcondition SPICE model which is provided by the device manufacturer, as well as switches for matching the transient I-V curve. The factory model is OK for emulating the device I-V curve in the positive voltage region, but does not conform to the I-V curve in the negative-voltage region. For this reason, two switches are used to correct the simulated I-V curve.

During the measurements, it was also found that the LED will be damaged if the current reaches +15A or -10A.

B. Modeling the Zener Diode

The Zener diode was modeled in a similar way. In the model which is shown in Fig. 4, diode 11 defines the I-V characteristics of the Zener under a negative pulse. Diode 10 and the switch determine the positive I-V characteristics. Diode 9 is used as a unidirectional switch.

A linear capacitance of 25 pF is also included. Its value is taken from the datasheet and verified through measurements.

The simulation results of this model (Fig. 5) show good agreement to measurements as well.

C. Modeling the IO Pin of the LED Driver IC

A reflection-based TLP system is used for insystem measurement of the transient I-V curve of the IO pin, which is modeled without knowledge of its internal circuit. Similarly, the model is a combination of linear and non-linear components. The non-linear behavior was measured by the reflection-based TLP system, and its linear part can be obtained by tuning the model parameters to conform to the measured S11. In this way, a complete model of the IO pin could be developed, as shown in the Fig. 6. R20 and C2 are these linear components which were obtained from the Sparameter measurement.

Similar to the Zener diode model, diode 7 defines the non-linear behavior of the device when a negative pulse is applied at the IO pin. Diodes 6 and 8 define the non-linear behavior when a positive pulse is applied to the IO pin.

A damage threshold of 22A was determined using a 13.5 ns pulse from the TLP to the IO pin. The transient I-V curve of the model is shown in Fig. 7.

D. Modeling the Ferrite Beads

Because ferrites are non-linear components, their equivalent inductances drop as through currents increasing, due to saturation effect. A non-linear model of the ferrite bead, as shown in Fig. 8, was obtained by defining its equivalent inductance as a function of current.

In this model, the linear parts include R1, C2 and R9, which are extracted from the impedance plot provided by the datasheet. The non-linear part of the ferrite model, the inductance as a function of current, was measured by a TLP, and modeled with following equation:

Where I stands for the current through the nonlinear inductor, L0 is the inductance value for I=0. Thus, for FB1 L0 equals to 60nH. Lsat stands for the saturated inductance which, for FB1, equals 20nH. The plot of the equation is shown in Fig. 9.

The model is validated by comparing simulation and measurement results, as shown in Fig. 10.

E. Modeling the Inductors

The inductors used in the circuit are assumed to be linear components, and the transient simulation result, as shown in Fig. 11, validates this assumption.

F. Modeling the Capacitors

The capacitors used in this circuit have anNP0 type dielectric, therefore it was expected that the capacitance would not change as a function of the voltage across the capacitor. Such expectation was validated by measuring capacitance variation with respect to voltage by using a TLP. These TLP measurements confirm that the NP0-dielectric capacitor can be modeled as a simple linear capacitor.

III. SYSTEM MODEL AND SEED ANALYSIS

A. The System Model

A system model was built by combining each of the experimentally obtained component models, as well as a TLP model as the source. The system model is validated through S-parameter measurements, as well as transient pulse measurements. The simulation result is compared to the measurement in Fig. 12. This comparison clearly shows that the injected 500 V TLP pulse is clamped to 9V by the protection circuit.

B. SEED Analysis

From Fig. 12, although it is known that the injected pulse is clamped to a low voltage, it is not known which one of the clamp circuit components is the primary clamping element. Additionally, it is not easy to predict what level of the injection pulse will damage the circuit, due to the fact that only a limited number of DUTs were available for real testing.

With the SEED method, the previous questions can easily be answered because it is possible to observe currents as they flow through various components in a simulation environment. In Fig. 13, it is clearly shown that more pulse current flows though the Zener diode during the first 10ns of an applied pulse before the protection diode inside the IO pin starts to conduct.

If the Zener diode is a more effective form of ESD protection we can ask if it is possible to remove FB1 before the IO pin to reduce cost. The simulation result in Fig. 14 shows that without the ferrite bead more current would flow through the IO pin, but not the Zener diode. Therefore, the ferrite bead has significant effect on the current that flows through the IO pin, and thus should not be removed.

SEED analysis may also tell us what the vulnerable parts in this circuit are, and how much margin left till the circuit would fail under a given injecting level, if the damage threshold of each component is known. For example, the simulation result in Fig. 15, shows that the current which flows though the LED is much larger than the current that flows through the IO pin. Therefore, for this circuit, the LED is more prone to damage than the driver IC, especially considering that LED device is usually placed at a location that has a greater chance to experience air discharge. It can be predicted that the LED will be damaged under 2000V TLP pulse because under this condition the LED’s through current reaches to 15A, which is its damaging threshold measured with 13.5ns TLP pulses.

IV.CONCLUSION

In this study, the SEED strategy is applied to analyze the ESD performance of a cell phone’s LED circuit. High current SPICE behavioral models of each component in the circuit were developed and validated against measurements. By combining these models with a TLP source model, major pulse-current paths, protection mechanisms, system transient response, and weak points of the protection circuit are revealed. These parameters can then easily be analyzed through simulation, instead of performing a large number of destructive measurements.

For next step, the TLP model can be replaced with an ESD gun SPICE model, so that we can predict the circuit’s response under real ESD gun contact discharge measurements. This may help circuit designers predict the ESD performance of a circuit before it is put in to production. This SEED strategy also facilities PCB level ESD protection design during initial product development, rather than traditional trial-and-error process.

ACKNOWLEDGMENT

This material is based upon work supported by the National Science Foundation under Grant No. 0855878, and supported by Sony Corporation of Japan.

Posted on

TN005 2.4GHz器件辐射的TEM单元测量

Overlaid spectra in GHz TEM Cell Measurment

下载TN005 2.4GHz器件辐射的TEM单元测量 (PDF)

 

1. 目标

本文的目的是演示如何使用EM601 TEM单元测量2.4 GHz设备(如蓝牙和WiFi)的频谱。

EM601-5.5 DC-5.5 GHz IC Stripline TEM Cell
EM601-5.5 DC-5.5 GHz IC带状线TEM小室

2. 测量设置

EM601系列TEM电池具有50 x 50 mm的大场注入面积,非常适合测量频谱USB蓝牙和WiFi设备,如图1所示。唯一需要的附加设备是一台计算机,用于为设备供电和激活,以及一台频谱分析仪。对于本文介绍的测量,使用了安捷伦E4448A频谱分析仪。

USB Bluetooth and WiFi devices
图1. USB蓝牙和WiFi设备

为了将蓝牙设备安装到电池中,将其从塑料外壳中取出,并将电缆焊接到其连接器端子上。修改后的装置如图2所示。使用覆铜板作为TEM电池盖,铣削一个USB连接器大小的孔,用于安装USB设备或退出电缆。图3显示了手机内的蓝牙设备及其USB电缆。

Modified Bluetooth device TEM Cell Measurement
图2. 用于TEM小室测量的改进Bluetooth设备
Bluetooth device mounted inside TEM cell
图3. 嵌入TEM小室内部的蓝牙设备

测量WiFi设备更简单,因为它很容易安装到电池中,并且只需要外部连接USB电缆,如图4所示。

 

WiFi Device mounted inside TEM cell
图4. 嵌入TEM小室内部的Wifi设备

 

3. 测量

使用安捷伦E4448A 3 Hz–50 GHz频谱分析仪进行测量,设置为:3 MHz RBW、50 MHz VBW、10.375 ms扫描时间、10 dB衰减、3 Hz启动频率和6 GHz停止频率。TEM电池的端口1连接到频谱分析仪,端口2在50秒内终止. 第一次测量的是TEM电池完全覆盖,内部没有设备。空电池频谱测量如图5所示。

Empty TEM Cell measurement (Dynamic Range Check)
图5. 空TEM小室测量 (动态范围检测)

 

蓝牙和WiFi设备的测量频谱如图6和图7所示。对于每个设备测量,它们都连接到一台计算机,并且功能齐全。蓝牙设备已进入搜索新设备模式的状态。

Spectra of Bluetooth device
图6. 蓝牙设备的光谱

 

Spectra of Wifi device
图7. Wifi设备的光谱

图8显示了覆盖所有图表的图。可以看出,这两个设备都在2.4 GHz频段内工作,当两个设备都存在并工作时,存在潜在的干扰。

Overlaid spectra in GHz TEM Cell Measurment
图7. GHz TEM电池测量中的叠加谱

4. 结论:

EM601-5.5 TEM电池非常适合测量GHz器件频谱。此外,可以定制TEM电池盖,以适合任何可以装入EM601的50 x 50 mm大电池的设备。

Posted on

PB2012.06 用于静电放电保护的非线性电容器

下载PDF – 用于静电放电保护的非线性电容器

NONLINEAR CAPACITORS FOR ESD PROTECTION

Hongyu Li, Victor Khilkevich, Tianqi Li, David Pommerenke, Missouri University of Science and Technology, USA;
Seongtae Kwon, Wesley Hackenberger, TRS Technologies, Inc., USA

Abstract – In order to protect electronic products from Electrostatic Discharge (ESD) damage, multi-layer ceramic capacitors (MLCC) are often used to bypass the transient ESD energy. Most
dielectric materials used in MLCC are nonlinear, since the dielectric constant decreases with increasing voltage, reducing the capacitance value, thus degrading the ESD protection effect. Using a large initial capacitance value will ensure sufficient ESD protection; however, the shunt capacitors also limit the signal bandwidth of the ESD-protected data channel, thus setting a maximal capacitance value at data voltage levels. This paper investigates the nonlinearity of capacitors and suggests improved tradeoff between ESD protection and data bandwidth by using the Antiferroelectric (AFE) capacitors as ESD protection. The dielectric constant of AFE material increases with increasing voltage. The voltage dependence of X7R and AFE capacitors are measured
using static and nanosecond transient measurements. The ESD protection effectiveness with different material capacitors are compared by simulation. Due to very limited availability of suitable
AFE material samples only hand-made capacitors have tested without investigating the long term stability of the material.

Index Terms— ESD protection, AFE material, nonlinear capacitor

关键词:ESD保护、AFE材料、非线性电容器

I. Introduction

ESD is one of the most important reliability problems in an electronic product. In order to provide ESD protection to electronic products, decoupling capacitors and series resistors can be used as shown in Fig. 1. The capacitors absorb the injected charge, and limit the maxi

I. Introduction

ESD is one of the most important reliability problems in an electronic product. In order to provide ESD protection to electronic products, decoupling capacitors and series resistors can be used as shown in Fig. 1. The capacitors absorb the injected charge, and limit the maximal

showed no noticeable voltage dependence. The measurement fixture is shown in Fig. 4. The two cylindrical devices are the PIO capacitors.

B. Static Measurement Results for X7R Capacitors

Static measurement results for X7R capacitors are shown in Fig. 5. All four capacitors (4.7nF, 50V) showed similar behaviour. The capacitance decreases from 4.7nF to about 1nF at 400V DC bias. We observed no damage to the capacitors at 400V.

C. Static Measurement Results for AFE Capacitor

The measurement result for an AFE capacitor is shown in Fig. 6. The capacitance is about 3nF without any DC bias, and increases with increasing DC bias voltage before the transformation from the AFE phase to the FE phase. For this AFE sample, the transformation occurs at about 325V, causing a peak in its capacitance value of about 8.5nF at 325V. In the FE phase the capacitor acts as normal capacitor, and the capacitance decreases with increasing DC bias voltage. The capacitance drops back to 3.5nF at 500V.

IV. Transient Measurement

The nonlinearity of the capacitors can be seen clearly from the static measurement results. However, ESD is a transient process of nanosecond time scale. ESD currents typically have rise time of less than 1ns. However, the voltage and current rise times at the capacitor is limited by the capacitance value and the source impedance (about 300 Ohm for an IEC 61000-4-2 ESD generator at lower frequencies and around 100 Ohm at higher frequencies). The voltage and current rise time at a capacitor with hundreds pF or a few nF is generally between a few and tens of nanoseconds. Transient measurements investigate if the capacitance can react with sufficient speed to provide ESD protection.

A. Transient Measurement Method

In the measurement setup illustrated in Fig. 7, C represents the capacitor under test. A pulse with duration of 70ns and a rise time of 150ps generated by the Transmission Line Pulser (TLP) is injected into the capacitor under test through a microstrip transmission line. A loop formed by a trace and vias is embedded underneath the transmission line. The mutual inductance between the transmission line and loop is used to measure the derivative of the current flowing on the transmission line. The current is obtained by integrating the measured derivative of the current. The voltage across the capacitor is measured with an oscilloscope.

The measurements capture the current derivative and the voltage across the capacitor. The post processing obtains the current and the voltage derivative. Low pass filtering is used for noise suppression and de-trending is used to remove the effect of scope’s imperfect DC-offset on the integration of the current derivative.

B. Transient Measurement Results for X7R Capacitors

If the TLP is set to 1200V charge voltage it takes about 60ns to charge the capacitor to 450V, as shown in Fig. 8. The stress was repeated many times to assure the phenomena are stable. Results from three repeats are plotted in Fig. 8. The change of the capacitance versus time for X7R capacitors is shown in Fig. 9. The results show that the X7R capacitors react fast enough to the transient signal

Fig. 10 compares transient and static measurement results for X7R capacitors and the trend of the nonlinearity matches well.

C. Transient Measurement Results for AFE Capacitor

If the TLP is charged to 2500V, it takes about 60ns to charge the AFE capacitor to 400V, as shown in Fig. 11. Results from three pulses are plotted in Fig. 11. Those indicate good repeatability. The peak and the dip at the beginning and the end of the pulse are due the parasitic inductance in the measurement setup and the large rate of current change at the beginning and end of the TLP pulse. The measurements indicate an inductance of about 5.5nH for the AFE capacitor test setup. Only 1.3nH had been measured for the X7R capacitor (fig. 8). Its 0603 package allowed a lower inductance placement within the test setup. The change of the capacitance versus time for AFE capacitor is shown in Fig. 12. The result shows that the AFE capacitor reacts fast enough to the transient signal, allowing this beneficial property being used for ESD protection. Fig. 13compares the transient and static measurement results for the AFE capacitor and the trend of the nonlinearity matches well. The deviation above 300V may be caused by the limitation of the transient measurement method. Due to its large capacitance it was barely possible to reach 400V at the highest TLP charge line setting of 2500V as shown in Fig. 11, causing uncertainties in the capacitance estimation as the capacitance values are derived just at the beginning of the falling voltage edge.

V. Comparision of the Capacitors for ESD Protection

The effectiveness of the capacitors for ESD protection can be compared by simulation. The nonlinear capacitor models are based on the static and transient measurements.

A. SPICE Model for Nonlinear Capacitor

The Analog Behavioral Model is used to model the nonlinear capacitor, as shown in Fig. 14. The capacitor is modeled by a controlled current source, GVALUE in PSpice, whose current is defined by equation (2). The time derivative of the voltage is modeled by using the discrete derivative of time (DDT) function in PSpice. A voltage dependent capacitance is specified by using a look-up table based on the measurement. This table contains voltage-capacitance pairs picked from points on the measured curve. The voltage input is nonlinearly mapped from the voltage values in the table to the capacitance values. Linear interpolation is used between table values [9].

B. ESD Current Source Model

ESD generator is modeled using the equivalent circuit as shown in Fig. 15. This circuit models the current and the impedance of the ESD generator. Initially, the capacitors are charged until the switch initiates the breakdown. C4, L2, R4 and R5 set the initial rise time, R1 and C2 represent the interaction between the body of the ESD generator and ground. The main discharge constant (330 Ohm, 150pF) is formed by R3+R4+R5 and by C1+C2+C4. R6 represents the ESD target and the current flowing through it is shown in Fig. 16. In this example, the ESD generator is charged to 2000V initially.

C. Capacitors to Compare

Sample1 from the X7R capacitors is selected to compare to the AFE capacitor. Fig. 17 shows the capacitance normalized to their value at 0V. In the simulation both X7R and AFE capacitors are de-normalized to 1nF at 0V; therefore, both protection circuits have the same frequency response, but different protection behavior.

D. ESD Protection Effectiveness Comparison

The simulation circuit is explained in Fig. 18. The device under protection is assumed as an IC. Diode ESD protection is commonly used in IC design. Here only these diodes are modeled and the IC’s internal structure is omitted. The destruction threshold of the commonly used human body model (HBM) test level is 2000V. The IC level HBM test and the IEC 61000-4-2 testing are both based on discharges from a human body, thus their total charge and pulse length are similar. The source impedance for the HBM testing is 1500Ω. Passing the HBM test ensures a robustness of the IC input for currents up to about 1.3A which we assume as the failure threshold of the simulation. Another consideration leads to the usage of a series resistor. Without such a resistor the internal ESD protection of the IC would compete with the PCB based protection, possibly leading to the IC protecting an external ESD protection. A series resistor allows for a sufficient voltage drop separating both protection methods electrically. A resistance of 200Ω is selected in this simulation. ESR and ESL represent the effective series resistance and inductance of the capacitor respectively, whose values are set to 100mΩ and 1nH. The circuit is excited by the ESD generator shown in Fig. 15. The ESD generator is charged to 2000V initially.

The critical current flowing into the IC is shown in Fig. 19. Using the X7R capacitor, it reaches 1.6A which is above the destruction threshold ensured by 2000V HBM testing of 1.3A. In contrast the increasing capacitance of the AFE capacitor limits the peak current below 0.9A.

In designing a protection circuit, the 0V capacitance is determined by the required signal bandwidth. The protection effect is determined by the capacitance ratio between the capacitance at the highest voltage reached during ESD and its 0V capacitance. The larger the ratio is, the better the ESD protection will be. For the X7R capacitor this ratio is usually about 0.3, while it reaches about 3 for the AFE capacitor investigated in this research. This larger ratio allows an improved trade-off between ESD protection and bandwidth.

VI. Conclusion

X7R capacitors are often used as ESD protection. In this application the voltage across the capacitor will surpass the rated voltage, often reaching 400V on a 50V capacitor. The voltage dependence of capacitors with two different dielectric materials, X7R and AFE, are measured using both static and transient measurement methods. Similar capacitance changes have been observed for static voltages and transient voltage changes. The X7R capacitors lose most of their capacitance while the AFE capacitors increase their capacitance values as the voltage increases up to a certain point as shown in Fig. 13, for example. This increasing nonlinearity of AFE capacitor improves ESD protection at a given signal bandwidth. The improvement of the ESD protection has been quantified with simulation. The temperature dependence of the AFE’s capacitance and the long term reliability of AFE capacitors have not been investigated.

Acknowledgement

This material is based upon work supported by the National Science Foundation under Grant No. 0855878. EMC

Posted on

TN002 ESD靶校准方法

下载ESDEMC_TN002 ESD靶校准方法 (PDF )

1. 校准目标

本报告的目的是校准ESD目标并检查其性能,并将结果与IEC 61000-4-2标准的要求进行比较。
IEC 61000-4-2标准的要求:

1. ESD靶的输入阻抗

The Front Side of ESDEMC A4001 ESD Current Target
图1 ESDEMC A4001 ESD电流靶的正面

用于测量静电放电发生器放电电流的静电放电电流目标应在内电极和接地之间具有输入阻抗≤ 2.1欧姆@直流。

2. 目标衰减器电缆链的插入损耗

ESDEMC A4001 ESD Current Target-Attenuator-Cable Chain
图2 ESDEMC A4001 ESD电流靶衰减器线缆链

 

不是指定ESD电流目标的插入损耗,而是指定由目标、衰减器和电缆组成的测量链的插入损耗。插入损耗的变化不得超过:
+/- 0.5 dB到1 GHz
+/- 1.2 dB 1到 GHz.
插入损耗的标称值S21:
S21 = 20*log [2*Zsys/(Rin + 50 Ω) ] dB
其中,Rin是负载为50Ω时链的直流输入阻抗。

2. 测量设置和结果:

设备 制造商 型号 序列号 校准日期
网络分析仪 Agilent E8357A US42070561 08/13/2016
VNA校准配套元件 Agilent 85092C MY46180831 08/14/2016
数字万用表 Keithley 2110 1374108 07/15/2016
数字电源 Agilent E3648A MY40004580 07/20/2016
ESD靶转接头线 ESDEMC A4002 A4002-001 09/02/2016

表1. 本报告中使用的测量设备
1. 用于DC输入阻抗
应使用LCR仪表或4线源测量仪表(SMU)测量直流输入阻抗。电极应与目标输入并联。在该校准报告中,目标与20 dB衰减器、RG400电缆和50欧姆终端相连。应测量约2.00欧姆的值。
2. 用于频率响应
ESD电流目标、衰减器和同轴电缆连接到目标适配器,以确定频率响应。典型设置如图3所示:

Mount ESD Target on to Target Adapter Line and connect to VNA
图3 将ESD目标安装到目标适配器线路上,并连接到VNA

 

The Insertion Loss - S21 of ESDEMC A4001 ESD Target Chain (SN A4001-195)
图4 ESDEMC A4001 ESD目标链(SN A4001-195)的插入损耗-S21

 

 Transfer Impedance of the ESDEMC A4001 ESD Target Chain (SN A4001-195)
图5 ESDEMC A4001 ESD目标链的传输阻抗(SN A4001-195)

为了测量目标衰减器电缆链的插入损耗,使用网络分析仪测量S21。设置的S21结果如图4所示。红色虚线是ICE 61000-4-2标准的限值。因此,该ESD目标在ICE 61000-4-2标准的规范范围内。

3. 保持电流靶性能

保持电流靶性能至少每两年对当前电流靶性能进行一次验证。验证目标的直流特性就足够了。理由是,整体机械几何结构的变化非常不可能,因为它们需要很大的力。唯一可能发生损坏的地方是接头(目视检查)和电阻器处,因为靶中心导体上的力过大。如果电阻器断裂或受到其他损坏,这些变化将在直流和高频下出现。
测试可以通过向靶注入约1 a的电流来完成,同时用50欧姆终止目标。直流传输阻抗,定义为通过50欧姆终端测量的电压除以约1A的输入直流电流。其偏离预期值不得超过2%。必须注意在与电压测量点不同的两点注入电流。这是典型的4线电阻测量。建议在靶材正面注入电流,并测量靶材背面的电压。T型接头可用于同时连接直流电压表和50欧姆终端。通常,建议在直流电流的两个相反极性下进行测试,并取两个电阻读数的平均值。这抵消了不同材料触点之间可能出现的热电压的影响。由于4线4触点连接设置中耦合的噪声,只要目标安装在大接地层中,直接使用4线4触点阻抗计可能会导致不稳定的结果。建议首先在已知的低阻抗(例如1欧姆)电阻器上测试测量设置。

参考:IEC 61000-4-2标准ed2.0 – 2008

Posted on

TN001 靶转接头线校准方法

Face-to-face adapter line calibration test setup

下载ESDEMC_TN001 ESD靶转接头校准方法 (PDF )

Model A4002-N ESD Target Adapter Line

图1.模型A4002-N ESD靶转接头线

1.校准目的:

这篇报告的目的是校准ESD靶转换头线并检查它的特性并与IEC 61000-4-2标准的需求结果进行比较。
IEC 61000-4-2标准的需求:
50欧姆的圆锥转接头线连接50欧姆的线缆到ESD靶的输入上。在几何学上,它会平滑地从50欧姆同轴线缆延展到ESD电流靶的直径。 如果靶的阻抗计算直径比例d/D没有等于50,靶转接头线需要使内导体的外部直径等于电流靶内电极的直径。阻抗的计算会决定填充圆锥转接头线材料的介电常数(通常为空气)。

靶转接头线会有50欧姆+/-2%从DC到4 GHz的阻抗。两个面对面安装的靶转接头线的反射系数会好于30 dB 在1 GHz,当入手损耗在相同配置小于0.3dB时会好于20 dB在4 GHz。

2. 测量设置和结果:

在测试中,两个相同的ESD靶转接头线面对面安装并连接校准网络分析仪。

Face-to-face adapter line calibration test setup

图2. 面对面的转接头线校准测试设置

测量结果S11和S22的值展示了ESD靶转接头线的入射系数,根据标准数值会好于30 dB到1 GHz ,好于20 dB在4 GHz,S21或S12展示了入射系数小于0.3 dB。示例下的结果通过了IEC 61000-4-2标准的需求。

Insertion Loss and Reflection Coefficient of 2 Face to Face Mounted ESDEMC A4002 ESD Target Adapter Lines

图3. 两个面对面安装的ESDEMC A4002 ESD靶转接头线的入射损耗和反射系数

Posted on

PB2010.11 TVS集成对系统级ESD鲁棒性的影响

下载PDF – TVS集成对系统级ESD鲁棒性的影响

EFFECTS OF TVS INTEGRATION ON SYSTEM LEVEL ESD ROBUSTNESS

50 Words Abstract – Higher integration of Transient Voltage Suppression (TVS) functionality into ASIC I/O cells implies lower system costs. But as the ESD pulse is directed deeper into the system, migrating the TVS clamping function from the periphery of the system to a central ASIC may actually reduce the system’s ESD robustness. ESD current reconstruction scanning can be used to trace the current path on a PCB, and possibly within an IC. The article compares the current spreading during and ESD for different ESD protection methods.

I. Introduction

The inevitable trend in system design for ESD robustness has tended toward higher integration of Transient Voltage Suppression (TVS) functionality into ASIC I/O cells. In low cost systems where the entire device has been distilled into a single “System on a Chip” (SOC) and perhaps an additional DDR memory device and a power supply and clock generator, the addition of discrete TVS devices near I/O connector ports can add appreciable costs to the parts count and in the case of a system with just a few USB or Ethernet ports, can double the assembly/placement costs for the entire PCB.

By shifting the ESD clamping into the highly integrated SOC these costs can be eliminated, however, this requires that the aggressor ESD pulse must be allowed to travel deep into the system where new susceptibilities to system upset may be triggered. While the cost is reduced, and the system ESD level survivability (resistance to permanent damage and hard failures) may be retained, the relocation of TVS clamping from the periphery of the system PCB to a central ASIC may actually reduce the system’s ESD robustness and resistance to upset and soft errors.

This paper demonstrates an improved methodology for quantitatively analyzing and potentially predicting robustness of different system level ESD protection circuits, topologies and layout permutations on a given product. The methodology uses current reconstruction scanning, a methodology to observe the ESD current spreading in a time resolved fashion [2, 5, 6].

II. Measurement Techniques

The objective of this analysis is to characterize what happens throughout the PCB, at various “nearby” nodes when an ESD pulse enters the system through an I/O port, or other means.

Two different analysis techniques are used:

Susceptibility scanning: This determines the local susceptibility of circuits to field injected noise, e.g. ESD like pulses

Current reconstruction scanning: This determines in a time resolved fashion the spread of current after an ESD strike on the system

What is needed is an analysis technique to quantitatively identify all areas of susceptibility on a board, and then relate that to potential I/O entry vectors. This makes it possible for the designer to correlate and potentially predict how a system level IEC61000-4-2 ESD strike may cause a system upset, and provides a method for objectively comparing improvements to the system design.

For example, a designer with a prototype failing minimum system level ESD testing may need to compare different types of discrete TVS clamp solutions near the I/O connector, versus a costreduced alternative I/O cell integrated into an interior system ASIC.

It is a common practice to place ESD protection as close to the perimeter of the system as possible in order to shunt the energy back to the chassis and out of the system as soon as possible.

However, even in the case of a well protected system, upset in an apparently unrelated subsystem may still occur (i.e. an ESD strike to a USB port upsets a PC’s video memory) making blind debug of the system upset extremely problematic.

By combining ESD susceptibility scanning [5] with a new reciprocal technique for “current spread” scanning [1,3,6], a matrix of potentially related aggressor and victim nodes can be identified and provide a comparative focal point for iterative improvement in design robustness.

A. Susceptibility Scanning Testing

1. Equipment

The scanning setup comprises a robotic 3D scanner with test control computer, Transmission Line Pulser (TLP), and DSO for data capture (See Figure 1).

We used the SmartScan system from Amber Precision Instruments [2]. For this test a 10mm horizontal loop probe was used for field injection (Figure 2). The maximum TLP charge level is set be a non-destructive 1kV, with a modified network to minimize the falling edge rate applied (Figure 2).

The scanning resolution is 5 by 5 mm and can traverse the entire system PCB area. When desirable, the system PCB can be mounted in as much of the system level enclosure as desired for closer relation to system level tests. The primary objective here is to probe the extent of the PCB design, routing and components, given a fixed case and mounting enclosure for the product. Certain systems, especially small handheld devices may dramatically hinder access to stacked PCBs or grounding brackets and consideration should be given to the extents of the scans.

2. Procedure

The iterative scanning process traverses a predetermined area of interest on the PCB, alternately injecting a pulse, and then checking the system under test for continued operation. The initial pulse is 4kV until a system upset is detected and the stepped failure level is then tested at the failure location and recorded. In this particular example, when the router operation was upset (reset) due to pulse injection, the router would stop replying to HTTP requests for the configuration setup page (a typical “recoverable loss of function” criterion as might be used in standard system level ESD testing).

Failure criteria are determined on a system-by-system basis, as they would be with a manual system level ESD testing. In this particular example, the test system repeatedly sends Ethernet requests to the Device Under Test’s (DUT’s) configuration stack. When the upset occurred in this case, the DUT would hang and stop responding to requests. At this point, the DUT would be reset by the system test controller and move on to the next test point on the grid.

B. “Current Reconstruction” Testing

In a corollary to the Susceptibility Scanning, the same TLP waveform is injected into a particular I/O port of interest, and the scanning probe is used to “listen” to the PCB.

At each point on the defined grid, the sensed H-field is recorded and processed at a low, non-destructive level creating a new surface plot of energy flow due to the injected pulse. The sensing methodology must take care to sufficiently shield the probe from E-field pickup, and/or remove this component from the measurement capture. [1,7] This does not actually require the system to be functioning, and it may be performed with and without power depending on the failure mechanism to be analyzed. However, the pulse needs to be large enough to trigger the non-linear ESD protection devices, but not so energetic that it causes permanent damage, or a “hard failure” of the system. This creates a great deal of data which can be postprocessed for myriad perspectives on the design.

By trapping the entire pulse at each position, a time variant surface plot can be reconstructed by windowing an interval of interest at various times during the TLP (or IEC or HMM) pulse applied. By post-processing multiple frames with incremental windowing of the pulse, an animated “movie” of the ESD current spreading can be assembled.

In Figure 6, the obvious entry vector of the residual current from the USB port to the SOC ASIC is seen in the upper left corner at the connector where a TVS clamp shunts much of the pulse.

Additional analysis can contrast the current reconstruction path with and without a discrete TVS clamp installed. Without the clamp installed (Figure7a), the current flowing in the signal traces is much higher than with the clamp (Figure 7b), and can be seen coupling into other unrelated, nearby nodes (blue circles.) This may indicate a link into other subsystems if these coupled nodes are related to other susceptible areas identified in the susceptibility scanning.

This potential problem can then be evaluated or eliminated from consideration by overlaying these plots, and comparing the resulting plots of different selections of TVS devices, layouts or ASIC revisions to determine the ESD robustness of each solution.

For example, the original Susceptibility Scan from Figure 5 is shown here expanded in Figure 8.

This plot is then overlaid with the Current Reconstruction Scanning plot of a particular USB port (Figure 9).

This results in a graphical representation of ESD susceptible areas which can be “reached” externally from that particular USB port (Figure 10).

Repeating this procedure for each I/O port (or other potential system level ESD injection point) yields a new plot (and associated peak susceptibility values and positions on the PCB) for each port or injection point of the system. This does not replace IEC61000- 4-2 testing, for example, but rather aides in the debugging of the design when an unexpected susceptibility is discovered.

In Figure 10, the method correctly identifies that the USB pins of the ASIC are of course susceptible to strikes on the USB port. Here, traditional TVS clamping methods can be expected to improve overall system robustness. However, if the scan overlay indicated that a sensitive DRAM or CLOCK pin was within the area of current spreading from the USB injection port, then the robustness improvement solution might simply require a reoriented layout of the USB and CLOCK/DRAM traces.

Such areas can also unexpectedly be aggravated by migrating the system level ESD protection into the ASIC by driving a larger residual ESD pulse current deeper into the system. The overlaid susceptibility plots for the integrated and external TVS solutions in Figure 7a and 7b can be compared to ensure that the integrated clamping solution does not create other robustness issues elsewhere in the system.

This analysis methodology can be used to help identify, compare and grade the relative improvement of each protection solution to problems at the system level.

Acknowledgements

The authors would like to thank Michael Hopkins of Amber Precision Instruments for his assistance.

Posted on

PB2010.11 静电放电发生器在空气放电模式下向产品放电的全波模拟

下载PDF – 静电放电发生器在空气放电模式下向产品放电的全波模拟

FULL-WAVE SIMULATION OF AN ELECTROSTATIC DISCHARGE GENERATOR DISCHARGING IN AIR-DISCHARGE MODE INTO A PRODUCT

Abstract—This paper introduces a methodology to simulate the currents and fields during an air discharge electrostatic discharge (ESD) into a product by combining a linear description of the behavior of the DUT with a nonlinear arc resistance equation. The most commonly used test standard IEC 61000–4-2 requires using contact-mode discharges to metallic surfaces and air-discharge mode to nonconducting surfaces. In the contact mode, an ESD generator is a linear system. In the air-discharge mode, a highly nonlinear arc is a part of the current loop. This paper proposes a method that combines the linear ESD generator full-wave model and the nonlinear arc model to simulate currents and fields in air-discharge mode. Measurements are presented comparing discharge currents and fields for two cases: ESD generator discharges into a ground plane, and ESD generator discharges into a small product.

Index Terms—Air-discharge mode, cosimulation, electrostatic discharge (ESD) generator, full-wave modeling.

关键词:空气放电模式、联合模仿、静电放电(ESD)发生器、全波模拟

I. INTRODUCTION

Simulating electrostatic discharge (ESD) allows predicting the currents and fields seen within a device under test (DUT) during an ESD, thus it helps to predict failure levels [1], [2]. The most commonly used test standard IEC 61000–4-2 [3] requires using contact-mode discharges to metallic surfaces and air-discharge mode to nonconducting surfaces. If an air discharge is attempted to a nonconducting surface, a discharge to a conducting part can occur.

In contact mode, the output waveform is proportional to the charge voltage, thus, the ESD generator can be analyzed as a linear system in both time domain (TD) and frequency domain (FD) [4]. Those models [5]–[8] for contact mode differ in the software used, the upper frequency limits, and if a specific commercial model of an ESD generator is simulated. However, the numerical modeling of an air discharge is more complex due to the highly nonlinear behavior of the arc [9]–[14]. The generator needs to be separated into the linear sections comprising the metallic elements, resistors, capacitors, and the nonlinear arc. It has been shown that the arc can be modeled as a time-varying resistor valid for the first tens of nanoseconds [13]. This model needs to be integrated into the numerical model.

Air-discharge currents badly repeat. Even if the voltage and speed of approach are kept the same, ESD currents will vary strongly from discharge to discharge. The variations are due to different arc lengths and not a direct result of corona or speed of approach [13]. In [12], a method to combine the arc model from Rompe and Weizel with an equivalent circuit of the discharging object is shown. This methodology is expanded in this paper to combine a linear full-wave model of the ESD generator and the DUT with a nonlinear arc model. Currents and fields are obtained.

Section II introduces the methodology. Sections III and IV verify the methodology by comparison to measured data. Section V discusses the application and the limitations of this method.

II. METHODOLOGY

In general, different processes are possible for coupling SPICE to a full-wave solver: Simultaneous solution exchanges voltage and current information with a SPICE-like solver after every time step of the full-wave solution [15], [16]. Sequential solutions first calculate the S-parameters of the linear section of the circuit and then combine them with the nonlinear part of the circuit in SPICE. We use the second method. It allows reusing the S-parameters to save calculation time, if only the arc parameters are changed.

More in detail, a four-step process is used, which simulates linear parts in full wave and nonlinear in SPICE. The arc attaches at two points: at the ESD generator tip and at the DUT. These two points are used to define a port. In the first step, the impedance at this port is calculated. This is the impedance looking into the DUT and a Noiseken ESD generator (ESS2000). The simulation is performed using computer simulation technology (CST) [17]. Both the TD and FD solver can be used. Although the impedance Z11 is calculated in the full-wave model for a given distance (0.7 mm) between the ESD generator and the DUT, different distances will influence the result little as long as the distance is in the arc length range (0.3–3.0 mm). The tip to ground capacitance is small relative to the distributed capacitance of the rod. This impedance is transformed into a form suitable for TD simulation. Here, the commercial software Broadband SPICE [21] was used. An order of 28 was selected to generate the circuit. SPICE then combines the impedance description from step 1 with an arc model based on the law of Rompe and Weizel. This law describes the arc during the first tens of nanoseconds as a resistance and has been validated for ESD applications [18], [19]. The resulting current is reimported into CST as the excitation waveform of the current port, which is placed between the two points that had been previously selected to define the impedance port to calculate Z11 to obtain fields and currents within the ESD generator and the DUT. The process is summarized in Table I.

The detailed combination in SPICE is now shown (see Fig. 2). The Z11 describes the linear part of the system. Once the Z11 has been obtained, it needs to be transformed into a form suitable for TD simulation. Software tools like IDEM [20] or Broadband SPICE [21] have been used successfully in this research. The subcircuit created from Z11 is not unique. Its complexity can be user defined, which depends on the transformation algorithm, the error, and the order of interest.

The arc of an ESD can be modeled by breaking it down into different phases. The first phase is the resistive phase. The arc is best modeled by a time varying resistance. In the second phase, which is usually reached after a few tens of nanoseconds, the impedance of the external circuit is larger than the impedance of the arc. In this case, the arc often acts more as a constant voltage drop of about 25–40 V. The rising edge of the ESD is the main contributor to the radiated and inductive coupling into DUTs. For this reason, we concentrate on the resistive phase and do not model other aspects (e.g., how the arc extinguishes). Multiple models describe the resistive phase or arcs [18], [19], [22]. In [13], it has been shown that the model of Rompe and Weizel is the most suitable for ESD simulation, as it can correctly describe the effect of the arc length on the rise time and peak current. The arc resistance can be calculated as follows [13]:

The structure of the SPICE model is shown in Fig. 2. A step function having a rise time of approximately 30 ps was used as the source. The rise time is selected by two criteria. If it is too long, then it will influence the current rise time. The current rise time should be determined only by the arc resistance law and the linear equivalent circuit. Further, the rise time cannot be too small, if the pulse contains strong frequency components beyond the range, in which the impedance is calculated, it can lead to instabilities in the SPICE simulation. The fast voltage rise starts the arc resistance model. The current rise time is not determined by the rise time of the step function, but by the arc resistance model. The subcircuit represents Z11 . The user provides the voltage and the arc length to calculate the discharge currents. The longest possible arc length in a homogeneous field is given by the Paschen law [13]. Such arc lengths would occur in air discharge for low approach speeds or in humid air conditions. The long arc length leads to slow rise times and lower peak values. Longer arc lengths than the length given by Paschen’s equation are possible in strongly nonhomogeneous fields, e.g., if the discharge is between an ESD generator and a sharp edged metal part, or if the discharge is gliding on a nonconducting surface. Very short arc lengths occur at high approach speeds and in dry air [9], [13], [23], leading to fast rise times and very high peak current values.

In the following, we will first apply this methodology to a discharge to a ground plane, mainly for verification purposes, and then to a discharge to a small MP3 player.

III. CASE 1: ESD GENERATOR DISCHARGE TO A GROUND PLANE

A. Z11 Between the Tip of the ESD Generator and the Ground Plane

The structural and discrete elements of the ESD generator are linear with respect to voltage. We further assume that the DUT acts linearly. For obtaining the current injected by the arc, this does not require that no nonlinear effects take place inside the DUT; it only requires that the current injected into the DUT is proportional to the charge voltage. For example, if an internal ESD protection device would clamp a trace voltage while the ESD current is injected into the ground system of the DUT, then, this clamping would have hardly any effect on the current, thus, the DUT would act as a linear device, as seen by the ESD generator. However, if secondary breakdown occurs, e.g., a spark within an attached two-wire power supply, then this could strongly affect the ESD current, thus, the modeling approach might lead to wrong results.

Both TD and FD solvers can be used to obtain Z11 . We observed the FD simulation giving a more reasonable Z11 result and using less simulation time. The simulated Z11 for the structure of the ESD generator above a ground plane is shown in Fig. 3 as the dotted line. This result is verified by comparison with measurement and an approximate SPICE model of this ESD generator [4]. The model contains sufficient detail for achieving a good match to measured impedance data, and correctly represents the 110-pF capacitor and 330-Ω resistor structure inside the ESD generator at lower frequencies. The calculation takes about 15 h on a PC (CPU 3.20 GHz, 16G RAM).

ESD generators have long ground straps. It increases the simulation time if the full length is included into the simulation domain. As most disturbances are caused by the fast changing parts of the currents and fields, one may not need to include the full ground strap into the model. The ground strap mainly influences the falling part of the waveform. The SPICE model shown in Fig. 4 includes a 3500-nH inductor to model the ground strap. A shorter ground strap will reduce the time between the first and the second peak of the discharge waveform.

The first step obtained the impedance representing an ESD generator discharges to a large ground plane. In the next step, the impedance is transformed into the TD suitable form and combined with a nonlinear arc equation in SPICE.

B. SPICE Simulation for the Discharge Current

Fig. 6 illustrates the effect of the arc length on the current waveform. It shows SPICE-simulated discharge currents for a 5-kV charge voltage. An arc length of 1.1-mm equals the Paschen length, such a discharge current would be expected at high humidity and slow approach speeds. A more typical value at moderate approach speeds is 0.7 mm. At this value, the rise time will be somewhat similar to the rise time of an ESD, as given in the IEC 61000–4-2 standard (about 850 ps). A more extreme case is given by the 0.3-mm arc length simulation. Very dry air and high approach speeds might lead to such a discharge. The simulated current peak value is 26 A and the rise time is 150 ps.

C. Reimport of Currents Into CST

For obtaining the fields, one needs to reimport the discharge current into the full-wave model as the excitation waveform. This is discussed and validated in the second case example.

D. Validation by Measurement Results

The current into the large ground plane was measured using an ESD current sensor, as described in [3]. In Fig. 7, the SPICEsimulated discharge currents are compared to the measured data for different approach speeds. Even if the exact approach speed or arc lengths are not known, it shows that the ranges of arc lengths used in the simulation are representative for discharge currents obtained in the experiment. A more in-depth comparison based on measured arc length values can be found in [13].

IV. CASE 2: ESD GENERATOR DISCHARGE INTO A SMALL PRODUCT

A. Z11 Between the Tip of the ESD Generator and the DUT Surface

This case simulates a discharge into an MP3 player, a small, nongrounded DUT. The whole geometry is shown in Fig. 8. The MP3 player model includes the main blocks of the DUT similar to [24]. In brief, the major blocks of the player (metal frame, battery, display, PCBs) are modeled as metal blocks connected at the locations of connectors and frame connection points.

The DUT is placed on a dielectric sheet above a larger ground plane. This forms a capacitor having a capacitance of about 25 pF, leading to a higher value of Z11 at lower frequencies. The value for Z11 was obtained, as shown in Fig. 9. The comparison between Z11 of the ESD generator and the large ground plane and Z11 of the ESD generator with the MP3 player is shown in Fig. 10. It mainly shows the smaller capacitance at lower frequencies; at higher frequencies the impedance of the 25-pF capacitor formed by the player against the ground plane is lower than the source impedance of the ESD generator, thus, the impedance in case 2 is similar to the impedance seen in case 1, the discharge to a large ground plane.

B. SPICE Simulation for the Discharge Current

The Z11 defined between the discharge tip and the MP3 player was transformed into a subcircuit using Broadband SPICE. The subcircuit combined with the arc model gave the simulated discharge current for different user-defined charging voltage and arc length. The simulated discharge current at the 5-kV charge voltage with different arc lengths is shown in Fig. 11.

The obtained peak values and rise times are tabulated in Table II. The arc length has a very strong effect on the parameters shown, especially, the current derivative.

C. Reimport of Currents Into CST

To obtain transient fields, the current waveform obtained from the SPICE simulation is reimported into CST as the excitation waveform. The current source port is placed between the two points that had been previously selected to define the impedance port to calculate Z11 . One check is worthwhile: If the Z11 representation used in SPICE would perfectly match the Z11 from the FD full-wave simulation, then the port voltage obtained during the full-wave simulation using the reimported current would match the port voltage (= voltage across the arc) in the SPICE simulation.

For case 2, the SPICE-simulated current was imported back to the CST model as the current source. The comparison of the port voltage in the SPICE model and the port voltage in the CST model in Fig. 12 shows a good match.

The simulation using the reimported current allows simulating the fields within and around the MP3 player by placing appropriate monitor probes. If these probes are placed close to the metallic surfaces of the MP3 player, then they represent the surface current densities and the displacement current densities, which can be used to estimate the coupling into bond wires of an IC, traces, and flex cables for predicting ESD upset threshold levels. Before current and field results are shown, the measurement methods are introduced.

D. Validation by Measurement Results

The current was injected into the small product, and the magnetic field was measured. To capture the current injected into the MP3 player, an F-65 (1 MHz–1 GHz) current probe was used, as shown in Fig. 13. The magnetic field was measured using a small shielded loop and a Tektronix 7404 (4 GHz BW, 20 GS/s) oscilloscope.

At 5-kV charge voltage, a NoiseKen ESD generator was discharged into the player. The player was placed above a large GND plane with a dielectric sheet between them. Figs. 13 and 14 illustrate the setup.

The relationship between approach speed, humidity, and arc length is not of deterministic nature, but given by the influence of the humidity on the statistical time lag [13]. Thus, on an average, one will observe shorter arc lengths with increasing approach speeds for a given charge voltage. For achieving short arc length discharges without reducing the humidity, the surface had been cleaned using alcohol and fast approach speeds have been used, longer arc lengths are achieved by slow approach speeds. Shown are examples of the captured waveforms for different approach speeds.

1) Measured Discharge Current: The current clamp’s frequency response falls off above 1-GHz bandwidth, thus, the fastest rise time of a step response signal would be approximately 300 ps. Fig. 15 shows the measured discharge currents for different approach speeds.

The simulation results are compared to the measured results for verification. The fast rise time result is shown in Fig. 16. The simulated discharge current for a 0.3-mm arc length and 5-kV charging voltage gives a discharge current with a rise time of about 200 ps and a peak value of 21 A. The measured discharge current has a rise time of about 300 ps and a peak magnitude of about 22 A. The difference can be explained by the limited bandwidth of the F-65 clamp. Due to the difficulty in measuring arc length, we can only approximately compare measured and simulated results. Nevertheless, the comparison shows that the simulated and measured data are within the same ranges.

In Figs. 17 and 18, the comparison of simulation discharge current for 0.7-mm and 1.1-mm arc lengths is shown. They match well with the measured results.

2) Measured Magnetic Field: This is to confirm the last step of the process: Injecting the SPICE simulated current back into the full-wave simulation for obtaining fields. A shielded loop was placed 5 cm away from the product (see Fig. 14). A deconvolution was performed to obtain the field strength from the captured voltage at the probe output. The deconvolution is mainly an integration process, having two deviations from the ideal integration. At lower frequencies, high-pass filtering is performed to avoid the accumulation of the oscilloscope’s small but relevant dc offset during the integration. Second, at higher frequencies, the self-inductance of the probe in conjunction with the 50-Ω load, leads to a self-integration, thus, no external integration is needed above 3 GHz. The resulting magnetic fields are shown in Fig. 19. The data match well. The measured rise time is about 250 ps. By using the SPICE model, one can estimate the arc length from the rise time. Repeated simulations indicate an arc length of about 0.4 mm. The Paschen length for 5 kV is about 1.1 mm at sea-level air pressure. Thus, the combination of the speed of approach and the statistical time lag reduced the arc length in this measurement to 35% of the Paschen value, leading to a very fast rising ESD current.

Several field probes were placed in the full-wave model to monitor the magnetic field. A probe that is 5 cm away from the discharge point gives the H-field data shown in Fig. 19. The result matches well with the measured data.

V. DISCUSSION

The methodology allows predicting the currents and fields in and around a product. There are three types of limitations in the methodology.

The most obvious one results from the limited ability of simulating details in the product and within the ESD generator. As with every simulation, the number of unknowns and the ratio of the smallest to the largest detail will limit the size of the model. The methodology allows circumventing this at least partially, especially for small products. If the product is small, then the fields inside the product will be dominated by the fields caused from the injected current and not by fields directly coupling from the body of the ESD generator. Those fields would especially be significant in the contact mode, in which the field components that are greater than 1 GHz are often caused by the rapid voltage breakdown in the gas-filled relay that initiates the discharge. As this analysis is for an air discharge, one will find the strongest high-frequency components directly at the arc, as with further distance from the arc high-frequency components will be attenuated by both frequency-dependent loss and radiation. If the fields are dominated by the injected current, then one can use a relatively simple model of the product just to determine the current, but in the last step, in which the current is reinjected into the product, a more complex model of the product can be used, but a very simple model of the ESD generator (and a forced current).

The second limitation results from the need for providing the arc length for the arc resistance calculation. Although possible, arc length measurements are difficult to implement. In a simulation, we suggest the following approach. At first, an arc length should be selected that leads to an air-discharge current that is similar to the contact-mode discharge current, as specified in the IEC 61000–4-2 standard. For 5 kV, this is about 0.8-mm arc length. Values for other voltages can be found in [13]. As a very slow rising current, the Paschen value can be selected, leading to discharges of lower severity and as extremely fast rising current; a value of about 30% of the Paschen length is suggested. This value is based on experimental evidence. In measurements that captured the arc length [13], we found it possible even under very dry air and clean surface conditions to obtain arc lengths of less than 30% of the Paschen value.

The third limitation is related to the stability of the TD SPICE simulation. In this simulation, a very rapid change of resistance is combined with a SPICE impedance model created from fullwave simulation. If instabilities occur, one should inspect the SPICE model for passivity and causality, in addition, one can simulate the discharge using longer arc lengths first, as these show a slower change of the arc resistance.

The main application of this model lies in the simulation of ESD to products. For example, it is known that the arc length tends to be small for fast approach speeds in dry air. The short arc length leads to fast rise times and high peak values. Using this model, one can quantify the fields inside a product for different arc lengths. Further applications are the simulation of grounding conditions of products on the arc, and thus, the current. Further, the model can be extended to the case of secondary breakdown, e.g., an ESD occurs to an ungrounded metal part leading to a second discharge from this ungrounded part to the main part of the DUT.

VI. CONCLUSION

This paper proposes a method for simulating an ESD generator discharging in air-discharge mode into a product. The linear and the nonlinear part of the problem are separated to simulate the linear part in a full-wave solution and the nonlinear arc in SPICE. The SPICE results are reimported into the full-wave problem as the excitation. This allows the fields inside a product during an air discharge to be obtained. The method has been verified by the comparison of simulated current and transient field results with measurements.

Posted on

PB2010.06 用于检测EMC应用中谐振的近场探头

下载PDF – 用于检测EMC应用中谐振的近场探头

NEAR FIELD PROBE FOR DETECTING RESONANCES IN EMC APPLICATION

Abstract— Resonances degrade the product’s EMI or immunity performance at resonance frequencies. Near field scanning techniques, like EMI scanning or susceptibility scanning determine the local behaviour, but fail to connect the local behaviour to the system level behaviour. Resonating structures form part of the coupling paths, i.e., identifying them will aid in understanding system level behaviour of products. In this article, a near field probe (patent pending) is proposed to detecting the resonances frequencies, locations or resonating structures and their Q-factors. The probe is suitable for integration into an automatic scanning system for analysing resonances of PCBs, cables, structural elements etc. The mechanism of the probe has been verified with full wave tools (CST MWS and Ansoft HFSS). Two samples of application are presented.

I. INTRODUCTION

Resonances in products are caused by the circuit topology and by the geometry of structural elements, cables, etc. They can form lumped (L-C) element resonators or they can be of distributed nature. Resonances may be caused by IC interconnect, traces, cable placement and structural elements of a system [1][2]. It has been observed that radiated immunity failures usually occur in relatively narrow frequency bands. This cannot be explained with broadband, simple (like inductive) coupling mechanisms. Instead coupling from resonances must be considered. The resonating structures can also form antennas and couple to the far field, consequently increase the EMI.

Some methods for detecting resonances are known. Firstly, a S11 measurement method injects RF energy to a probe and measures the signal reflected returning from the probe. If the probe is able to couple to a resonating structure, a dip in the S11 will be observed at the resonance frequencies. This method has been known for at least 90 years (grid dipper). The depth of the dip is sensitive to the coupling to the resonating object, and making it difficult to implement this method in an automated scanner. The second method uses two orthogonal probes. They are decoupled from each other. A VNA (Vector Network Analyzer) measures S21 which expresses the coupling between the two probes [3]. The third method uses a far field antenna driven by a VNA to illuminate the DUT (Device Under Testing) and measures the excited local magnetic (or electric) field using probes [1][2]. This method will only excite the resonances that can be excited by the far field. The near field excitation will also excite resonances that are locally excitable. Besides these three methods, a newly designed resonance detection probe that integrates an electrically small cone structure with a shielded magnetic field loop is proposed in this paper. Full wave simulation based on CST MWS [6] and Ansoft HFSS [7] and measurement results are shown and results of resonance scanning are presented.

II. DESCRIPTION OF THE PROBE GEOMETRY

Two probes have been designed that differ in the plane the loop is mounted, shown in Figure 1 and Figure 2.

Figure 1 shows the main parts of the probes: The small shielded horizontal loop and the cone. The coax cables are connected to the VNA . Figure 2 shows the second design and it uses a vertically mounted shielded loop.

Details are shown in Figure 3. A semi-rigid cable forms the shielded loop. A gap in the shield allows the magnetic field to couple. The inner conductor of the second coaxial cable connects to the lower part of the cone structure. This excites the cone in its inner side.

III.MECHANISM OF RESONANCE DETECTION

The loop forms an H-field sensor. The cone structure is more complex. It is excited on its inside. To better understand its functions, full wave simulation was used in CST MWS. Field probes are placed underneath the cone, while the cone is placed above a large ground plane. Figure 4 shows the geometry. Results of the E-field divided by 377 and the magnetic field are shown in Figure 5. The Efield dominates the coupling.

The resonance scanning probe contains both the cone and the loop sensor. An S21 measurement is used to identify resonances. If no resonating structure is present the S21 value needs to be as low as possible, allowing the S21 to rise if resonating structures are detected. Figure 6 shows the full wave model in HFSS. Simulation and measurement results are compared in Figure 7. They match well.

IV.SAMPLES OF RESONANCE DETECTION

Test samples have been scanned to identify resonant structures, frequencies and Q-factors. Two sample structures are shown below. Sample 1 is a test structure containing a ring structure with microstrip traces. Sample 2 is the commercial product.

Figure 8 shows the ring structure with microstrip traces. In Figure 9, scan results are overlaid with a photo of the test sample. This data presentation does not distinguish between different resonant frequencies. The color indicates the magnitude S21 of the resonances. The resonance shows strongly at the first resonance frequency is around 240 MHz.

Resonances increase the coupling from the field to the circuits, then cause decrease the immunity and enhance the emission of system. They are often the “missing link” between system level performance and local level. Therefore, identifying resonances is an important step in understanding immunity sensitivities or emission maxima. This paper presents a method for detecting resonance in the PCBs, ICs, and components. The product is scanned by an auto-scanning system (Smartscan) [8] and resonances are detected via S21 measurement.

The methodology was applied to scan the motherboard of a computer, shown in Figure 10. It clearly reveals the cable resonance around 109 MHz shown in Figure 11.

V. CONCLUSIONS

Resonances increase the coupling from the field to the circuits, then cause decrease the immunity and enhance the emission of system. They are often the “missing link” between system level performance and local level. Therefore, identifying resonances is an important step in understanding immunity sensitivities or emission maxima. This paper presents a method for detecting resonance in the PCBs, ICs, and components. The product is scanned by an auto-scanning system (Smartscan) [8] and resonances are detected via S21 measurement.

Posted on

PB2010.06 用近场扫描法重构电流的探针表征和数据处理

下载PDF – 用近场扫描法重构电流的探针表征和数据处理

PROBE CHARACTERIZATION AND DATA PROCESS FOR CURRENT RECONSTRUCTION BY NEAR FIELD SCANNING METHOD

Abstract- previously a measurement technique for ESD current spreading on a PCB using near field scanning was developed in order to connect the local ESD sensitivity to system level ESD failures in time and spatial domain. The concept of such scanning methodology is proved and several scanning results were processed. However the validation, precision and weakness of such methodology need to be further investigated before the application of such scanning methodology on complex circuit or system.

This article investigates the current reconstruction by near field scanning technique and methodology. It studies the probe factors including coupling frequency response characterization and deconvolution method, spatial resolution for scanning and orthogonal-scan data combine process.

I. INTRODUCTION

This article is a research continuation of a previous paper “A Measurement Technique for ESD Current Spreading on A PCB using Near Field Scanning”. The ESD injection setup and current return paths are shown in Fig. 1 and Fig.2

II. PROBE CHARACTERISTICS

To successfully recover both the magnitude and direction of injected surface current or coupled trace current from probe’s near field induced voltage signal, the understanding of probe characteristics is of great significance. A probe’s coupling frequency response; loss, spatial resolution and directional response need to be evaluated to estimate how well the injected surface current or coupled trace current can be recovered. Then the reverse process from local induced probe signals to desired surface or trace current vectors can be constructed based on the probes characteristics.

A. Frequency Response and Deconvolution Method

For using a magnetic probe to capture a transient magnetic field or current and recover it numerically, the probe’s magnetic coupling frequency response is one of the most important factors to construct the reverse process, or probe frequency response deconvolution.

The probe should have enough inductive coupling bandwidth to cover the main spectrum of the transient magnetic field or current. Then a compensation function of the coupling frequency response can be calculated to recover the transient magnetic field or current from the induced probe voltage signal. In addition, the experimental measurement including the probe should have enough signal noise ratio and dynamic range of H-field or current coupling to get recoverable measurement results.

A probe’s coupling factor for surface current or trace current can be measured by a terminated TEM cell or trace as Fig. 3 shows:

The coupling mechanism between the probe and the excitation can be modelled as Fig 4.

From the model, the frequency response is inductive coupling dominated and the excitation recovery process can be achieved with a process as Fig 5 shows:

A compensation function of the probe’s frequency coupling response and loss with filters is then created with steps as Fig 6 shows:

Finally the desired field or current data can be rescaled from the recovered excitation_ An example of probe deconvolution is followed_ Fig_ 6 is the measured probe voltage signal from TEM Cell excitation. After the deconvolution process a comparison of transient H-field from processed probe signal and directly measured H-field are shown in Fig 8:

Some of the high frequency and low frequency components are lost due to the filters integrated into the compensation function, but they are important to reject low frequency noise and high frequency resonance. Overall the method works well and the recovery result matches direct measurement.

B. Spatial Resolution

Spatial resolution of a probe reflects how well a magnetic field probe can resolve the field strength variation or a trace current probe can resolve the trace current underneath during the probe’s spatial offset.

A shielded single loop probe is usually good for magnetic field measurement since it captures the magnetic flux crossing the loop and the loop size can be reduced to increase spatial resolution.

A shielded trace current probe against plane current coupling was design with complex structure for ESD current reconstruction scanning_ Its spatial resolution is measured and simulated over a 2.8 mm wide trace with sideway offsets as Fig 9 shows:

The probe frequency coupling responses of all the sideway offsets are obtained as Fig 10 shows:

Then the responses at the same frequency (in the inductive coupling frequency range) for al1 the sideway offsets are plotted in Fig.ll :

For a trace current probe, the spatial resolution indicates the scanning resolution should be much smaller than the 6 dB width to get the maximum coupling position scanned_ And the side peaks coupling should be reduced as good as possible in order to avoid “fake trace current” from scanning result.

C. Directional Response and Orthogonal Data Combine

The directional response of a probe reflects how it couples to field or current during rotation, usual1y from the maximum to the minimum coupling direction.

A shielded single loop probe usual1y has good directional response that fol1ows cosine drop from the maximum to minimum coupling direction. If a probe’s directional response follows cosine drop, the orthogonal measurement signals such as V x and Vy can be separately processed and directly mapped to vectors Hx and Hy, or Jx and Jy.

A shielded trace current probe, depending on the coupling mechanism, may not have good directional response that fol1ows cosine drop. Thus the process of orthogonal scanning data needs to compensate for its directional response.

The directional response of a probe is only compensable in its linear dynamic range, or inductive coupling range. Fig 12 shows a trace current probe with deficient directional response. The linear region is from 50 MHz to 1 GHz.

The normalized directional response of the probe is shown in Fig 13. The 90 degree rejection is less than 20 dB, which suggests certain common mode coupling exists.

The coupling frequency responses of a probe with better directional response are shown in Fig 14. The probe has wider inductive coupling range and dynamic range (from 5MHz to 3GHz). In addition, its normalized directional responses in this range are shown in Fig 15.

The orthogonal scanning data can be compensated if its directional response is symmetry between [0, 90] and [0, -90], and also monotone decreasing in [0, 90], like Fig 15. Suppose an orthogonal data set of V x and Vy is measured from scanning using this probe as Fig 16 shows.

The trace current under the probe is 8 degree off the X direction and 90-8 degree off the Y direction, The process to calculate I and 8 from V x and Vy is to map the V xlVy in the interpolated V xlVy curve as the Fig, 17 shows.

Since the probe’s normalized directional response is monotone decreasing, the VxlVy curve is also monotone decreasing and there is a one-to·one correspondence relation between the V xIV y and 8. Then the maximum coupling response V can be calculated from the probe’s normalized directional response as Fig 18 shows, Finally, the trace current vector I can be recovered from previous deconvolution process.

In this way, the current vector I can be recovered precisely as long as the probe’s normalized directional response is monotone decreasing, even it doesn’t follow cosine drop. The common mode h-field coupling maximized at 90 degree direction won’t be added into the recovered vector 1.

Ill. CONCLUSIONS

In this paper, several important probe characteristics for recovering surface current density J or trace current I by near field scanning method are analysed, The probe’s coupling frequency response characterization and compensation methodology are described; probe’s spatial resolution and relation to minimum scanning resolution are illustrated; and probe’s directional response and compensation method for orthogonal scanning data are explained.

In the next step, probe design and optimization for current reconstruction by near field scanning should be continued for better frequency response, spatial resolution, unwanted coupling rejection, sensitivity and directional response. Secondly how a probe or structure can influence the near-field around the measurement target should be studied, especially when the measurement interest is the coupled signal on the target, not the driven signal on the target.

Posted on

PB2009.08 一种基于近场扫描的PCB板ESD电流扩展测量技术

下载PDF – 一种基于近场扫描的PCB板ESD电流扩展测量技术

A MEASUREMENT TECHNIQUE FOR ESD CURRENT SPREADING ON A PCB USING NEAR FIELD SCANNING

Abstract — Electrostatic discharge (ESD) can cause interference or damage in circuits in many ways e.g., by E- or Hfield coupling or via conduction paths. Although we can roughly estimate the voltage and current at the injection point during an ESD event, the real offending parameter is mostly the ESD current spreading throughout the system. Those currents can be simulated if great simplifications of the system are accepted.
However, even in moderately complex systems the ability to simulate is limited by lack of models and computational resources. Independent of the complexity, but obviously not free of its own limitations is a measurement technique that captures the current as a function of time and location through the system.
This article describes the proof on concept of ESD such a measurement technique that allows reconstructing the spreading current as a movie from magnetic field measurements. It details the technique, question of probe selection and how to process the data to present the current spread as a movie.

 I. INTRODUCTION

ESD can damage or disrupt a system. Understanding of system level ESD has been approached from different directions, such as ESD generator modelling [1], in circuit measurements [2], air discharge analysis [3], numerical simulation of currents and fields, protection circuit analysis, etc.

One of the effective methods for analysing ESD robustness is using a three dimensional scanning system to localize ESD sensitive areas or traces [4, 5, 6]. In conjunction with the circuit information the root cause of a system level problem often can be fully understood.

However, as in near field scanning, it is not obvious to connect local results (e.g., sensitive area, or strong fields in near field EMI scanning) to system level performance. For ESD one needs to understand which current densities, field strengths and derivatives are to be expected at one location if an ESD is injected into a test point.

The sensitive areas found by near field susceptibility scanning might not be those, which will receive a lot of current or field strength during an ESD. Thus, the current spreading during an ESD needs to be known to connect local sensitivity data with system level responses.

This article reports on our proof of concept for a current spreading measurement method. The main objective of the research is to develop a method to measure and reconstruct current spreading and field coupling in or close to circuits by scanning; to correlate system level ESD with scanning level ESD in time and spatial domain; and at the end to analyze and extract circuit and layout design strategies for ESD current protection.

This paper is mainly describing the methods of ESD current reconstruction on PCB. Research beyond this simple PCB will be continued in the future.

II. TEST STRUCTURE

For a proof of concept the structure of the device under test (DUT) and the experiments based on it have to be simple but meaningful. Fig. 1 shows the PCB structure we used:

It is a simple two layer PCB with 3 traces on the top layer and a solid ground plane on the bottom layer. Signal probing (for traces) is performed via SMA male to male connectors at the back side of the PCB. Their ground connects to a large ground plane. Injection is performed via a coax connection on the edge of ground layer. This allows easy numerical modelling. Fig. 2 is the setup picture:

For the test setup above, the injected current from the cable centre conductor will spread on the top PCB ground layer (both sides of the copper) and return via the 6 SMA connectors outer conductors to the large aluminium ground, then return to the injection cable through the injection structure. This current spreading and return is shown in fig.3 (top view) and fig.4 (side view).

III. MEASUREMENT METHOD

To capture the current, the magnetic field is measured by placing a probe close to the surface of the PCB. An ESD pulse is injected into the PCB and the magnetic field is captured. Due to the close proximity of the probe to the PCB one can approximately equate the magnetic field to the surface current density. Then the probe is moved to the next location and another pulse is injected. This is repeated until a sufficient number of locations have been measured. There are a couple of choices for setting up the measurements:

a) Probe Selection.

Before choosing current probes, we need to understand the E and H field coupling of the ESD scenario [7, 8, 9]. Fig. 5 shows the 3 field coupling paths we are concerned about:

We want to suppress the E-field. There are two relevant currents: The current density on the PCB and the currents on the traces. We are interested in both. The magnetic fields of the trace currents are often much weaker than the magnetic field of the surface current density.

Therefore it is difficult to measure trace currents by the same H-field probe that is used for the ground layer current. However, the field components are different. The trace current has an Hz field component. It is possible to separate the trace current by measuring the Hz component over the PCB. Probe selection requirements are:

1) The probe needs to suppress the E-Field, otherwise the E-field coupling will easily override the H-field coupling from the current.

2) The probe for measuring the ground layer current can be a shielded vertical loop probe measuring Hx or Hy. The trace current that is induced into the traces generates much weaker Hx Hy components, they are mostly overwhelmed by the Hx and Hy components from the ground layer current. In the test we used a 6 by 8 mm coaxial shielded vertical loop probe to capture Hx and Hy from the PCB ground layer current.

3) A good probe of measuring trace current in this scenario needs to well reject ground layer current coupling. For this application, a 3 by 3 mm patent pending trace current probe was designed to capture the trace current. It measures the trace currents Hz components since Hz is dominated by trace current locally and incorporate other features.

b) Time or Frequency Domain.

The first set of data presented here has been captured using a transmission line pulser (TLP) as source (about 300 ps rise time) and a real time oscilloscope to capture the signal. The use of a Network analyser (NWA) is also discussed further down this article.

A. TLP and Oscilloscope Scanning Method Setup

Fig.6 shows the test setup for current reconstruction scanning using a TLP and an oscilloscope.

The current is injected from the right middle edge (x =300mm, y = 150mm) of the PCB into the ground layer. From the injection point current spreads over the ground layer as fig. 3 showed before, and couples to the 3 traces. All traces are terminated by matched loads. A shielded vertical loop will measure the current spread on the surface of the PCB with 2 orthogonal directions (measuring Hx and then Hy components separately). In this way, two sets of data will be created for data processing.

The oscilloscope records data after receiving a trigger from the TLP. Providing the TLP repeats well all measurements are “synchronized” and show the current spread when plotted as a function of time. The probe couples to the time derivative of the current density via a probe factor. Thus multiplication by the factor (yet unknown, but a pure function of geometry) and integration would allow determining the current in absolute values.

B. Network Analyzer Scanning Method Setup

Our test setup is linear with respect to current. Thus, one is not forced to use a high voltage generator as injection. A network analyzer with time domain transformation can be used instead as setup in fig. 7 shows. The setup of the network analyzer is very similar to the TLP and oscilloscope method, the only difference is that the injection part is connected to network analyzer port 1; the probe is connected to the network analyzer port 2. S21 is measured and transformed to the time domain. To improve the signal to noise ratio, a 20 dB amplifier is added at the receiving port.

Its excitation equals the excitation of a step function (or the user could select an impulse transformation instead) [10]. For a linear system a network analyzer has many advantages over a direct time domain measurement:

It has better repeatability as it is frequency domain measurement, unlike TLP which uses a High Voltage relay to produce pulses.

Network analyzers have much better dynamic range than oscilloscopes

The time domain image of the signal injected by the Network analyzer is clean, e.g., there is no ringing, or overshoot. Fig. 8 shows the voltage waveform comparison.

IV. SCANNING RESULTS

A. Reconstructed Movie using the TLP and Oscilloscope Scanning Method on PCB Ground Layer

Fig. 9-12 show 4 fames of the reconstructed current spreading on the PCB surface when the shielded vertical loop probe is oriented at x-axis direction.

The first frame shows a very large current density at the injection moment. The current spreads in a circular fashion on both sides of the board as shown in frame 2 and 3. All frames here illustrate only the Hx component on the top side of the board. The board is connected to a large ground plane via SMA male to male connectors on PCB bottom side so most of the current will return through them. After the waveform reaches the left side of the board, reflections are visible in the last frame.

B. Reconstructed Movie for the Network Analyzer Scanning Method on PCB Ground Layer

Below are 2 current reconstruction frames obtained using the network analyzer scanning method:

The data shown in Fig.13 indicate that the wavefronts are better visible using the network analyser method. The large dynamic range of the NWA allows us to follow the current wave front over a larger distance.

However, it is necessary to use a network analyser that can cover the frequency range from 100 KHz – 3GHz; otherwise the missing frequency component will distort the time domain signal, especially the tails.

C. Data Process in MATLAB

The total field is reconstructed using MATLAB from two orthogonal scans (Hx and Hy). The scanning resolution was set to 1 by 1 cm. This leads to 30 by 30 scanning points for each scan. Fig. 14 shows 3 plots resulting from the recovering process.

The first plot is using the raw data taken from the Hy scanning. When the vertical loop probe is oriented such that the loop is normal to Y-axis, it measures the Hy component which is mainly generated by the current flowing in the direction of the X-axis.

The second plot shows the result of the Hx scanning. When the vertical loop probe is oriented such that the loop is normal to the X-axis, it measures the Hx component which is mainly generated by current flowing in Y direction. The first and second frames are snapshots at the same moment for better understanding and comparison.

The third plot in fig. 15 plots the root square sum of the raw data from the two orthogonal scanning results:

 This is the magnitude of the total horizontal H-field strength close to the plane which equals the current density on the PCB ground layer.

D. Trace Current Reconstruction

If the vertical loop is used, we can hardly see the H-field of the trace current (the trace current caused by the current injected into the PCB). It is overwhelmed by the magnetic field of the ground plane current.

Different probes have been designed a special probe just for the trace current. These probes detect the magnetic field from the trace while suppressing other field components. Fig.15 shows the comparison of the probe response when moving it across a trace during ground layer injection:

The vertical loop can hardly detect the trace current (blue trace). The horizontal loop detects the Hz component; it can detect the magnetic field of the trace current (green trace). The response of the trace current probe (red) detects only the trace current as one peak, which is located above the center of the trace.

Fig. 16 shows one frame of the current reconstruction using the trace current probe and a frame from the CST simulation movie. In both the trace current is visible.

One final remark on the trace current probe: It recovers the trace current well, but it is only sensitive to the Ix or Iy current, thus two scans need to be conducted for full reconstruction.

V. CONCLUSION

The paper presents a prove of concept for a measurement method that reconstructs currents spread as a function of time for ESD or other pulses injected into a system. A special probe is able to suppress the ground plane current to extract trace currents; its principle function has been shown.

The next steps are a comparison to simulated data and a comparison of local current density and field strength, as seen during a system level ESD tests compared to local current density and field strength as they are caused by local injection during ESD scanning. This will further help to connect local to system level results.

Posted on

PB2009.02 用自动近场扫描以识别共振

下载PDF – 用自动近场扫描以识别共振

AUTOMATED NEAR-FIELD SCANNING TO IDENTIFY RESONANCES

Abstract—Near-field scanning systems are a tool for rootcause ESD, EMI, and immunity analysis of electronic systems, as well as qualification methodology for ICs and modules. For emissions, they have developed into a standardized method. Development of universally accepted file formats for data exchange is on-going. Four main types of scanning have been implemented by this and other authors: Near-field EMI scanning, ESD scanning, radiated immunity scanning, and resonance scanning. This article concentrates on resonance scanning as a newly added method for automated EMC system analysis.

Near field scanning; ESD; resonance; EMI

关键词:近场扫描、静电放电、共振、电磁干扰

I. INTRODUCTION

EMC tests are performed on a system level, and thus do not reveal the root cause of a problem. Root-cause analysis is the daily bread of EMC engineers. Consequently, a wide variety of analysis methods have been developed, one of them is near field scanning. It finds application in emissions, immunity and coupling analysis:

Near field electromagnetic interference (EMI) measurement [1]-[3]

RF immunity scanning using modulated sine wave [4]

ESD scanning [5]

Resonance scanning.

The challenge in all of the scanning methods is relating local results to system level results. For example, if a clock frequency leads to strong emissions and near field scanning is performed, the clock traces will show up strongly. This indicates that the clock is the source, however it does not reveal that the areas of strong field at the clock frequency are causing the EMI problem (as they do not show the coupling path). Often, in EMI analysis, it is not strong fields that indicate a problem, but weak fields in areas where there should be none. Such an analysis requires system-level EMI knowledge, and cannot be directly implemented in software.

Immunity scanning shows areas where coupling to devices (either directly or via traces or cables) leads to disturbances. However, from the scan maps one cannot directly conclude that those areas are causing an observed system level failure. A highly noise sensitive integrated circuit (IC) in the middle of a board, being connected by short traces will probably not lead to a system upset, relative to a relatively robust IC that is connected to badly routed reset lines connected via unshielded flex cables. The examples above illustrate the difficulty in connecting local results to system results.

Many authors have devoted their research to closing this gap. For example, using near-field to far-field transformation to predict EMI from scan [6], using near field scan data to predict TEM cell measurement data that again can be connected to the far field [7], or using near field data as excitation in numerical models.

Near-field scanning shows locally strong fields, however, in most cases they do not identify the aspects of the printed circuit boards (PCB) or system design that lead to a failure. In this regard, near-field scanning is more of a source identification tool than a coupling path identification tool.

Identifying the coupling paths is the “holy grail” of EMC analysis. Resonant coupling paths are especially important, as they will couple energy very efficiently at the resonance frequency. Identification of resonances has been an important aspect of EMC analysis for decades. This article briefly reviews other scanning methods, and then presents an automated resonance scanning method.

II. EMI SCANNING

EMI scanning probes the local electric or magnetic field above an IC, PCB, or around a equipment under test (EUT). The data are usually used for identifying areas of strong magnetic or electric field. An implicit, but often incorrect, assumption is made that an area of strong field is the cause of EMI problems. The near-field information is used as follows:

Identifying the cause of an EMI problem

Comparing two boards or after a modification to the original case

Near-field – far-field transformations

Identification of current paths

Capturing data to be used as an excitation in a numerical simulation

III. IMMUNITY/ESD SCANNING

In immunity scanning the reaction of the EUT is tested. RF is injected into the EUT at different locations. Thus, for automatic scanning, a feedback needs to be established between the EUT and the scanning controller, such that the scanning controller “knows” if an error has occurred. The difference between immunity scanning and ESD scanning is the type of noise injected. Modulated RF signals are usually injected in immunity scanning, whereas narrow pulses are injected in ESD scanning. The injection usually takes places via the electric or the magnetic field, however direct injection techniques are possible.

IV. RESONANCE SCANNING

The challenge in EMC analysis is often locating the coupling paths and, to a lesser degree, locating the antennas. The most basic coupling theory for EMI predicts a broadband, or linear with increasing frequency, coupling strength. These models do not intend to take the complexity of real systems into account. Their use lies in the illustration of basic principles, and their direct application is limited to simple cases on PCBs or cases with well controlled field structures as they can be found in the TEM cell tests (IEC61967).

A. Are resonances important?

The most basic coupling mechanisms let us expect smooth (e.g. 20 dB/decade) coupling behavior. In practice, however, this smooth frequency behavior is not observed. For example, experience in immunity testing (IEC61000-4-3) of systems has shown that immunity failures are usually not of broadband nature, but rather occur in a relatively narrow frequency range. ESD is a pulsed, broadband disturbance, however EUTs often only respond to a narrow portion of the spectrum [8]. If emission testing is performed while the clock frequencies are varied over a wide range, we observe strong peaking in the radiated signals. All these examples are indicative of internal system resonances. At resonance frequencies, the EMI radiation or immunity sensitivity may increase by orders of magnitude. This signifies the importance of locating system resonances.

B. Where do resonances occur?

Resonances can be of lumped (L-C) or distributed nature. From smallest scale to largest scale, resonances may be found at:

IC power distribution resonances. The on-die capacitance and the interconnect inductance form an LC circuit, peaking the on-die power-ground noise at frequencies from about 10-1000 MHz

PCB power distributions form resonances. At lower frequencies by the interaction of decoupling capacitances, ESL and distributed inductances, at higher frequencies by the propagation delay within power traces or planes.

Traces on the PCB can resonate if not terminated at one end at least.

Ground fills of PCB can resonate if they are long and narrow, cross slots and not connected with sufficient vias to a ground plane [9].

PCBs that are connected via cables or flex circuits to other PCBs form resonators

Cables resonate

Heat-sinks

Structural elements, especially if they are long and thin

Enclosures

Cables on enclosure, power cables, I/O lines

On one side these resonances can couple to local voltages and currents, on the other side they can form antennas and couple to the far field. Thus, they need to be regarded as the link between effects seen in near field EMI scanning and the far field. In case of immunity testing the resonances will be excited by the far field and cause strongly, resonance enhanced voltages and currents increasing the likelihood of a failure at the resonance frequencies.

C. How to identify resonances

Resonance scanning is performed with the EUT turned off. It is a two port measurement (e.g. performed using a network analyzer). Different configurations are known: Far-field to far-field coupling as seen in resonances in radar cross sections to the well known grid dipper as used by ham radio operators. Figs. 1-3 illustrate three methods suitable for automated scanning:

A variety of probing methods can be used. Fig. 1 depicts a measurement method based on S11. It is similar to the grid dipper used for decades by ham radio operators. If there is no resonating structure for the probe to couple to, most of the RF energy injected into the probe will be reflected by the probe. If the probe is able to couple to a resonating structure, however, less energy will be reflected leading to small dip in the S11 value. This method couples and decouples locally, so it is more suitable to find local resonances, no matter how well they coupled to the far field. Other methods use two probes that are decoupled to each other, e.g., by their field structure [10], distance or field component. The network analyzer measures S21 which expresses the coupling from one probe to the other. If resonating structures can couple to both probes an increased S21 value will be observed at the resonance frequency. The method moves both probes to different locations while scanning. The method couples and decouples locally, however, as both probes do not have to have the same size and distance, one can adjust the amount far field or near field coupling. A third method does not use a local excitation but illuminates the EUT from an antenna placed at some distance, thus, only one probe moves. The moving probe measures the local magnetic field, excited by the far field and resonances are again identified by an increased S21.

D. Measurements on test structures

A set of test structures have been created to investigate different probing and data analysis techniques. An example test structure, partially overlaid by a test result is shown in Fig. 4.

The test structure of Fig. 4 consists of four traces on a 1.6 mm thick PCB. The traces resonate at frequencies between 380 MHz and 800 MHz. As other test structures thinner PCBs have been used increasing the difficulty coupling to the traces. To test if resonances in real systems can be identified an open iMac computer is used. The first level of data analysis plots the magnitude of the S21 response over the locations. Fig. 5 shows the result for the 1.6 mm PCB test structure.

The next step in data analysis determines the frequency at which the resonance occurs, and associates the vertical axis with the frequency (see Fig. 6 ). The peaks are identified by subtracting a reference (probe at a location having no resonance) from the measured S21 parameters. The peaks are identified and classified according to their Q-factor, resonance frequency and harmonic relationship.

The methodology was applied to an iMac computer, shown in Fig. 7.

The cable indicated by the arrows experiences a resonance at around 100 MHz. An analysis, showing the measured probe-to-probe response as a function of frequency, is shown in Fig. 8. It clearly reveals the cable resonance around 100 MHz.

V. SUMMARY

Scanning methods are a tool of growing importance for EMI and immunity analysis. Their main advantage is their ability to assist in root cause analysis. This paper has introduced resonance scanning as a method to identify system resonances. These resonances form the link between local effects and the far-field. The method extends known resonance identifying techniques to automatic scanning, taking into account the particularities of automated scanning.

Posted on

PB2003.11 电磁兼容(EMC)中静电放电(ESD)抗扰度测试的问题

下载PDF – 电磁兼容(EMC)中静电放电(ESD)抗扰度测试的问题

PROBLEMS WITH THE ELECTROSTATIC DISCHARGE (ESD) IMMUNITY TEST IN ELECTROMAGNETIC COMPATIBILITY (EMC)

Asia-Pacific Conference on Environmental Electromagnetics, CEEM’ 2003 Nov. 47,2003 Hanzhou .China

Jiusheng Huang*, David Pommerenke**, Wei Huang**
*)Beijing Institute of Electromechanical Technology, Beijing, China, jshuang@ESD-China.Com
* *) Electromagnetic Compatibility Laboratory, University of Missouri-Rolla, USA
***) Beijing University of Post and Telecommunication, Beijing, China

Abstract- Electrostatic discharge (ESD) immunity test is one of the important electromagnetic compatibility (EMC) tests. The IEC standard IECdlOOO-4-2 is the widely used standard to test the ESD immunity for electronic equipment. Many amendments such as amendment 1 (1998), amendment 2 (2000) have been published since 1995, but there is still problems with the ESD immunity test even with the 200x version. More than six ESD generators of different bands are tested for different equipment. The results show that the failure voltages of different ESD generators are vary much from different bands for the same test equipment. This may lead to the results incomparable when test the ESD immunity test in the EMC. Further studies show that there is a good correlation between the failure voltage and the induced voltage.

1. Introduction The electrostatic discharge (ESD) current waveform of the IEC61000-4-2 s&ndard[ 11 is shown in figure 1. It says the rise time of the first peak is 0.7-1 ns and the current is in the range of 3.375-4.125 A/kv. The current at 30 ns is in the range of 1.4-2.6 A/kv and the current at 60 ns is in the range of 0.7-1.3~kv. Many works were made on the research of the ESD current, electromagnetic and magnetic field radiated from the ESD[2-51. Any ESD generator is standard if its ESD current is per IEC61000-4-2 standard. The failure ESD voltage for the same equipment should be the same in certain tolerances. But the failure voltages for the same equipment are very large for more than six bands of ESD generators. This paper is to investigate the main reasons and the factors which influence the compatibility of the results.

2. Test 2.1 Test setups More than six bands of ESD simulators from different factors were used as the test equipment of the experiment. A high speed oscilloscope (TekTonix TDS7404 Phosphor oscilloscope 4GHz, 20GS/s) and ESD current targets and field sensors were used as the main equipment in our experiment.

2.2. Test Results

All the ESD generators are calibrated as the IEC6 1000-4-2 standard requirements. They have the same ESD current as the standard. The ESD failure voltages of the same electronic equipment for different bands of ESD generators were tested. The failure voltage may be very much from 1kV to even 6kV for the same equipment even if all the ESD current are accordant with the same standard. This may lead to the results incomparable when test the ESD immunity test in the EMC.

2.2.1 The influence of the ground strip to the ESD current waveform Many factors such as the parasitic capacitors and inductors will influence the waveform of the ESD current and the failure voltage in our experiments. The rise time, the first peak of the ESD current and the shape of waveforms of the ESD current are easily influenced by those factors. But those parasitic capacitors and inductors are constant in a given ESD generator when it is made in the factor. Other factors such as the length and shape of the ground strip are vary in the practice experiment. The waveform of the second segment is influenced by the RC network and the shape and position of the ground strip. Several tests are made to demonstrate the effects. A ESD generator is used to test the waveform. The results are shown in figure 3 and figure 4. Figure 4 has some offset in order to observe easily (Total Y offset 70%, Total X offset 20%)

It can be seen from figure 3 and figure 4 that when the ground strip is in winding, that is the inductance is very large, the waveform (Black) vibrating during the decay period. When the ground strip is in straight line, the waveform (Blue) is very similar to the waveform proposed by IEC standard. When tlhe ground strip is in other shape and position, the waveform is also influenced by the inductance.

2.2.2 ESD induced voltage Voltage induced by both the electric field and magnetic field radiated from ESD at a given distance can be easily measured than that of the electric field and magnetic field. It is mainly the induced voltage which makes the electronic equipment failure. So, more attention will be paid to the induced voltage. There &e two typical induced voltages which represent the real effects of ESD. One is the monopole induced voltage. It is mainly induced by electric field. Another is the loop induced voltage which may be induced by both magnetic field and electric field if the sensor is not electric shielded. In order to test the ESD current, monopole induced voltage and loop induced voltage. Three channels of the digital oscilloscope is connected to ESD current target, monopole with 10″ length and the half circular loop with diameter of 13 mm respectively. It will be unstable due to the lower sampling rate when three or more channels are used simultaneously. But the concurrent phenomena can be easily observed.

2.3 ESD current and ESD induced voltage In order to test the ESD current and ESD induced voltage in the sensor. Two channels of the oscilloscope are connected the ESD current target and the loop sensor. The ESD current is much varies with the ESD induced voltage in shape and duration. The induced voltage is very short in duration than that of the ESD current shown in Fig.6. The induced voltage may be small just like noise after several ns even if the ESD current is increase.

Figure 6 shows that the ESD current will increase after 10 nanoseconds due to the discharge of the capacitor in the ESD. But the induced voltage doesn’t increase any more. This further demonstrates that the induced voltage doesn’t correlate with the ESD current.

For the same equipment the failure level of discharge may be from 1kV to 6kV. But there is good correlation between the ESD susceptibility and induced voltage from different simulators. The correlation coefficient R= -0.88567, standard deviation SD= 0.86476[2].

3. Conclusions and Future Works ESD current for different ESD simulators are tested. The ESD susceptibility of computer with different CPU and auto switch are experimentally investigaied. ESD induced voltage are tested for different ESD simulators. Some conclusions are summarized [ 51. 1. The parasitic inductor and capacitor of the ESD simulator are critical factors which will influenced the both the waveform of the ESD current and the ESD model of discharge, Different ESD simulators have different parasitic parameters that lead to the different ESD susceptibility. 2. The shape and position of the ground strip of the ESD simulator will influence the inductor of the LCR and lead to the generation of different waveform of the ESD current. These two factors are mainly source lead to the variation of the ESD susceptibility of the electronic equipment. 3. ESD induced voltage doesn’t correlate with the ESD current but it is correlated with the induced voltage. It is generated by the process of contact of the relay in the ESD. The duration of the ESD voltage is about 5 nanoseconds and the typical duration of ESD current is more than 100 nanoseconds. The ESD susceptibility is very complicated. It may be influenced by both the ESD current and Electromagnetic, and magnetic field radiated from the ESD. If the ESD current and the induced voltage can be defined more exactly, the ESD susceptibility test results may be more repeatable.

Acknowledgements

Thanks go out to Dr. Thomas Van Doren of EMC laboratory, University of Missouri-Rolla for his warmly supports to the ESD work, Kai Wang and all students in UMR for their supports and helps during my stay in UMR from 2002-2003.